These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 37579218)

  • 1. Wire ThRoUgh Snare Twice (Wire TRUST) technique: A novel method to grasp a lead with inaccessible ends as a supportive femoral approach for transvenous lead extraction.
    Kasai Y; Haraguchi T; Morita J; Kitai T; Okada T; Tamura T; Munakata Y; Tsujimoto M; Kasai J; Fujita T
    J Cardiovasc Electrophysiol; 2023 Sep; 34(9):1990-1995. PubMed ID: 37579218
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Successful coronary sinus left ventricular lead extraction 9 years postimplantation using the wire ThRoUgh Snare Twice (wire TRUST) technique.
    Kasai Y; Morita J; Haraguchi T; Kitai T; Okada T; Suzuki K; Yamazaki R; Munakata Y; Kasai J; Fujita T
    Clin Case Rep; 2024 Jun; 12(6):e9039. PubMed ID: 38840753
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Needle's Eye Snare as a primary tool for pacing lead extraction.
    Bracke FA; Dekker L; van Gelder BM
    Europace; 2013 Jul; 15(7):1007-12. PubMed ID: 23277531
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pacemaker lead extraction with the needle's eye snare for countertraction via a femoral approach.
    Klug D; Jarwé M; Messaoudéne SA; Kouakam C; Marquié C; Gay A; Lacroix D; Kacet S
    Pacing Clin Electrophysiol; 2002 Jul; 25(7):1023-8. PubMed ID: 12164441
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transfemoral extraction of pacemaker and implantable cardioverter defibrillator leads using Needle's Eye Snare: a single-center experience of more than 900 leads.
    Zhou X; Ze F; Li D; Wang L; Duan J; Yuan C; He J; Guo J; Li X
    Heart Vessels; 2020 Jun; 35(6):825-834. PubMed ID: 31786644
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pacemaker electrode repositioning using the loop-snare technique.
    Morris DC; Scott IR; Jamieson WR
    Pacing Clin Electrophysiol; 1989 Jun; 12(6):996-9. PubMed ID: 2472627
    [TBL] [Abstract][Full Text] [Related]  

  • 7. "Pigtail through snare" technique: an easy and fast way to retrieve a catheter fragment with inaccessible ends.
    Mori K; Somagawa C; Kagaya S; Sakai M; Homma S; Nakajima T
    CVIR Endovasc; 2021 Mar; 4(1):24. PubMed ID: 33651249
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Efficacy and safety of transvenous lead extraction using a liberal combined superior and femoral approach.
    Yap SC; Bhagwandien RE; Theuns DAMJ; Yasar YE; de Heide J; Hoogendijk MG; Kik C; Szili-Torok T
    J Interv Card Electrophysiol; 2021 Nov; 62(2):239-248. PubMed ID: 33029695
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Triple access transvenous lead extraction: Pull-through of a lead from subclavian to jugular access to facilitate extraction.
    Akhtar Z; Zaman KU; Leung LW; Zuberi Z; Sohal M; Gallagher MM
    Pacing Clin Electrophysiol; 2022 Nov; 45(11):1295-1298. PubMed ID: 35687737
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Successful avoidance of superior vena cava injury during transvenous lead extraction using a tandem femoral-superior approach.
    Muhlestein JB; Dranow E; Chaney J; Navaravong L; Steinberg BA; Freedman RA
    Heart Rhythm; 2022 Jul; 19(7):1104-1108. PubMed ID: 35245690
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Persistent left superior vena cava transvenous lead extraction: A European experience.
    Akhtar Z; Sohal M; Starck CT; Mazzone P; Melillo F; Gonzalez E; Al-Razzo O; Richter S; Breitenstein A; Steffel J; Rinaldi CA; Mehta V; Zuberi Z; Zaidi A; Gallagher MM
    J Cardiovasc Electrophysiol; 2022 Jan; 33(1):102-108. PubMed ID: 34783107
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Effect analysis of the modified wire-loop snare technique in retrieving severely tilted inferior vena cava filters].
    Yang H; Ge WN; Zhang JT; Zhu KJ; Niu LY; Wang HF; Wang YW
    Zhonghua Wai Ke Za Zhi; 2022 Dec; 60(12):1063-1068. PubMed ID: 36480873
    [No Abstract]   [Full Text] [Related]  

  • 13. Long loop technique with bifemoral access as salvage technique for repositioning of dislodged port catheters.
    Van den Bosch V; De Beukelaer F; Isfort P; Keil S; Kuhl CK; Bruners P; Pedersoli F
    CVIR Endovasc; 2022 Dec; 5(1):64. PubMed ID: 36512154
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Four-Stage Rocket technique: A novel strategy for lead extractions using laser sheaths from the femoral vein.
    Kawano D; Matsumoto K; Narita M; Tanaka N; Naganuma T; Sasaki W; Mori H; Ikeda Y; Kato R
    J Cardiovasc Electrophysiol; 2024 Jun; ():. PubMed ID: 38845191
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A steerable introducer-assisted wire-loop snare technique: A bailout for unsuccessful lead extraction by a Needle's Eye Snare.
    Isawa T; Honda T; Yamaya K; Toyoda S
    J Arrhythm; 2022 Oct; 38(5):821-823. PubMed ID: 36237864
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transvenous extraction of pacemaker leads via femoral approach using a gooseneck snare.
    Uslu A; Küp A; Kanar BG; Balaban I; Demir S; Gülşen K; Kepez A; Doğan C; Candan Ö; Akgün T; Altıntas B; Sadıc BO
    Herz; 2021 Feb; 46(1):82-88. PubMed ID: 33009623
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lock and dock: Two-step transvenous retrieval of a fractured femoral sheath with a vascular snare via the right internal jugular vein.
    Kasai Y; Kasai J; Haraguchi T; Kitai T; Morita J; Okada T; Tsujimoto M; Fujita T
    J Cardiol Cases; 2023 Oct; 28(4):176-179. PubMed ID: 37818439
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transvenous Lead Extraction in Patients With Arrhythmogenic Right Ventricular Cardiomyopathy.
    Barakat AF; Zmaili MA; Tarakji KG; Shah S; Abdur Rehman K; Martin DO; Brunner MP; Saliba WI; Kanj M; Ballout J; Baranowski B; Cantillon D; Niebauer M; Callahan T; Dresing T; Rickard J; Lindsay BD; Wilkoff BL; Wazni OM; Hussein AA
    JACC Clin Electrophysiol; 2019 Jun; 5(6):665-670. PubMed ID: 31221352
    [TBL] [Abstract][Full Text] [Related]  

  • 19. How adequate are the current methods of lead extraction? A review of the efficiency and safety of transvenous lead extraction methods.
    Buiten MS; van der Heijden AC; Schalij MJ; van Erven L
    Europace; 2015 May; 17(5):689-700. PubMed ID: 25687745
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Yoked catheter positioning in transseptal endocardial left ventricular lead placement.
    Lau EW
    Pacing Clin Electrophysiol; 2011 Jul; 34(7):884-93. PubMed ID: 21418248
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.