BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 37583330)

  • 1. [Preliminary experience of transcatheter pulmonary valve replacement using domestic balloon-expandable valve].
    Zhao ZG; Li RT; Wei X; Peng Y; Wei JF; He S; Li Q; Li X; Li YJ; Li X; Zhou X; Zheng MX; Chen G; An Q; Chen M; Feng Y
    Zhonghua Xin Xue Guan Bing Za Zhi; 2023 Aug; 51(8):825-831. PubMed ID: 37583330
    [No Abstract]   [Full Text] [Related]  

  • 2. Hand-sewn expanded polytetrafluoroethylene valved conduit for right ventricular outflow tract reconstruction.
    Qian T; Huang C; Lu T; Zhang H; Yuan H; Xie L; Wu Z
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2022 Jan; 47(1):94-100. PubMed ID: 35545368
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transcatheter Pulmonary Valve Replacement With the Melody Valve in Small Diameter Expandable Right Ventricular Outflow Tract Conduits.
    Shahanavaz S; Qureshi AM; Levi DS; Boudjemline Y; Peng LF; Martin MH; Bauser-Heaton H; Keeshan B; Asnes JD; Jones TK; Justino H; Aboulhosn JA; Gray RG; Nguyen H; Balzer DT; McElhinney DB
    JACC Cardiovasc Interv; 2018 Mar; 11(6):554-564. PubMed ID: 29566801
    [TBL] [Abstract][Full Text] [Related]  

  • 4. NuMED Covered Cheatham-Platinum Stent™ for the treatment or prevention of right ventricular outflow tract conduit disruption during transcatheter pulmonary valve replacement.
    Bishnoi RN; Jones TK; Kreutzer J; Ringel RE
    Catheter Cardiovasc Interv; 2015 Feb; 85(3):421-7. PubMed ID: 25257401
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Relationships Among Conduit Type, Pre-Stenting, and Outcomes in Patients Undergoing Transcatheter Pulmonary Valve Replacement in the Prospective North American and European Melody Valve Trials.
    Cabalka AK; Hellenbrand WE; Eicken A; Kreutzer J; Gray RG; Bergersen L; Berger F; Armstrong AK; Cheatham JP; Zahn EM; McElhinney DB
    JACC Cardiovasc Interv; 2017 Sep; 10(17):1746-1759. PubMed ID: 28823778
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Outcomes After Transcatheter Reintervention for Dysfunction of a Previously Implanted Transcatheter Pulmonary Valve.
    Shahanavaz S; Berger F; Jones TK; Kreutzer J; Vincent JA; Eicken A; Bergersen L; Rome JJ; Zahn E; Søndergaard L; Cheatham JP; Weng S; Balzer D; McElhinney D
    JACC Cardiovasc Interv; 2020 Jul; 13(13):1529-1540. PubMed ID: 32646693
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of transcatheter pulmonary valve replacement on the hemodynamic and ventricular response to exercise in patients with obstructed right ventricle-to-pulmonary artery conduits.
    Hasan BS; Lunze FI; Chen MH; Brown DW; Boudreau MJ; Rhodes J; McElhinney DB
    JACC Cardiovasc Interv; 2014 May; 7(5):530-42. PubMed ID: 24852806
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Implantation of the Melody transcatheter pulmonary valve PB1016 in patients with dysfunctional right ventricular outflow tract conduits.
    Morray BH; Jones TK; Coe JY; Gitter R; Martinez JZ; Turner DR; Gray RG; Lung TH; Berman DP; Levi DS
    Catheter Cardiovasc Interv; 2019 Feb; 93(3):474-480. PubMed ID: 30419603
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Single-Barrel, Double-Barrel, and Fenestrated Endografts to Facilitate Transcatheter Pulmonary Valve Replacement in Large RVOT.
    Kamioka N; Babaliaros VC; Lisko JC; Sahu A; Shashidharan S; Carazo MR; Jokhadar M; Rodriguez FH; Book WM; Gleason PT; Keeling WB; Jaber W; Block PC; Lederman RJ; Greenbaum AB; Kim DW
    JACC Cardiovasc Interv; 2020 Dec; 13(23):2755-2765. PubMed ID: 33303113
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transcatheter Pulmonary Valve Replacement Reduces Tricuspid Regurgitation in Patients With Right Ventricular Volume/Pressure Overload.
    Jones TK; Rome JJ; Armstrong AK; Berger F; Hellenbrand WE; Cabalka AK; Benson LN; Balzer DT; Cheatham JP; Eicken A; McElhinney DB
    J Am Coll Cardiol; 2016 Oct; 68(14):1525-35. PubMed ID: 27687194
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Percutaneous pulmonary valve implantation in grown-up congenital heart disease patients: Insights from the Zurich experience.
    Oechslin L; Corti R; Greutmann M; Kretschmar O; Gaemperli O
    J Interv Cardiol; 2018 Apr; 31(2):251-260. PubMed ID: 29277931
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transcatheter Pulmonary Valve Replacement for Right Ventricular Outflow Tract Conduit Dysfunction After the Ross Procedure.
    Gillespie MJ; McElhinney DB; Kreutzer J; Hellenbrand WE; El-Said H; Ewert P; Rhodes JF; Søndergaard L; Jones TK
    Ann Thorac Surg; 2015 Sep; 100(3):996-1002; discussion 1002-3. PubMed ID: 26190388
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Percutaneous pulmonary valve implantation for reconstruction of a patch-repaired right ventricular outflow tract.
    Esmaeili A; Bollmann S; Khalil M; De Rosa R; Fichtlscherer S; Akintuerk H; Schranz D
    J Interv Cardiol; 2018 Feb; 31(1):106-111. PubMed ID: 28940794
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Melody transcatheter pulmonary valve replacement: a single-center case series in Southeast Asia.
    Satawiriya M; Chandavimol M; Limsuwan A
    BMC Cardiovasc Disord; 2024 Jun; 24(1):301. PubMed ID: 38872098
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Immediate and long-term outcomes of percutaneous transcatheter pulmonary valve implantation.
    Fiszer R; Dryżek P; Szkutnik M; Góreczny S; Krawczuk A; Moll J; Moszura T; Pawlak S; Białkowski J
    Cardiol J; 2017; 24(6):604-611. PubMed ID: 28248409
    [TBL] [Abstract][Full Text] [Related]  

  • 16. SAPIEN valve for percutaneous transcatheter pulmonary valve replacement without "pre-stenting": A multi-institutional experience.
    Morgan GJ; Sadeghi S; Salem MM; Wilson N; Kay J; Rothman A; Galindo A; Martin MH; Gray R; Ross M; Aboulhosn JA; Levi DS
    Catheter Cardiovasc Interv; 2019 Feb; 93(2):324-329. PubMed ID: 30351525
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Is there a role for endovascular stent implantation in the management of postoperative right ventricular outflow tract obstruction in the era of transcatheter valve implantation?
    Kang SL; Ramroop R; Manojlovich L; Runeckles K; Fan S; Chaturvedi RR; Lee KJ; Benson LN
    Catheter Cardiovasc Interv; 2022 Mar; 99(4):1138-1148. PubMed ID: 34967102
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Physician-Modified Endograft-Facilitated Transcatheter Pulmonary Valve Replacement in Large Right Ventricular Outflow Tract.
    Ueyama HA; Greenbaum AB; Leshnower BG; Keeling B; Block PC; Byku I; Ligon RA; Grier E; Shekiladze N; Gleason PT; Xie J; Kim DW; Babaliaros VC; Duwayri Y
    Circ Cardiovasc Interv; 2023 Sep; 16(9):e013123. PubMed ID: 37577788
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of a novel hybrid strategy for transcatheter pulmonary valve placement in patients following transannular patch repair of tetralogy of fallot.
    Phillips AB; Nevin P; Shah A; Olshove V; Garg R; Zahn EM
    Catheter Cardiovasc Interv; 2016 Feb; 87(3):403-10. PubMed ID: 26527499
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transcatheter pulmonary valve replacement in surgically-created double-barrel right ventricular outflow tracts: A single center case-series.
    Boscamp NS; Maschietto N; Porras D
    Catheter Cardiovasc Interv; 2024 Feb; 103(3):455-463. PubMed ID: 38204358
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.