BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 37584126)

  • 1. [Development of a whole-cell biosensor for detecting organophosphorus pesticide methyl parathion in the farmland soil].
    Ma Z; Li M
    Sheng Wu Gong Cheng Xue Bao; 2023 Jul; 39(7):2706-2718. PubMed ID: 37584126
    [TBL] [Abstract][Full Text] [Related]  

  • 2. On-site screening method for bioavailability assessment of the organophosphorus pesticide, methyl parathion, and its primary metabolite in soils by paper strip biosensor.
    Ma Z; Li Y; Lu C; Li M
    J Hazard Mater; 2023 Sep; 457():131725. PubMed ID: 37295330
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Recombinant organophosphorus hydrolase (OPH) expression in E. coli for the effective detection of organophosphate pesticides.
    Jain M; Yadav P; Joshi B; Joshi A; Kodgire P
    Protein Expr Purif; 2021 Oct; 186():105929. PubMed ID: 34139322
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optical microbial biosensor for detection of methyl parathion pesticide using Flavobacterium sp. whole cells adsorbed on glass fiber filters as disposable biocomponent.
    Kumar J; Jha SK; D'Souza SF
    Biosens Bioelectron; 2006 May; 21(11):2100-5. PubMed ID: 16298521
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of a novel optical biosensor for detection of organophosphorus pesticides based on methyl parathion hydrolase immobilized by metal-chelate affinity.
    Lan W; Chen G; Cui F; Tan F; Liu R; Yushupujiang M
    Sensors (Basel); 2012; 12(7):8477-90. PubMed ID: 23012501
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An optical microbial biosensor for detection of methyl parathion using Sphingomonas sp. immobilized on microplate as a reusable biocomponent.
    Kumar J; D'Souza SF
    Biosens Bioelectron; 2010 Dec; 26(4):1292-6. PubMed ID: 20685107
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Microbial biosensor for detection of methyl parathion using screen printed carbon electrode and cyclic voltammetry.
    Kumar J; D'Souza SF
    Biosens Bioelectron; 2011 Jul; 26(11):4289-93. PubMed ID: 21605969
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Recombinant Organophosphorus acid anhydrolase (OPAA) enzyme-carbon quantum dot (CQDs)-immobilized thin film biosensors for the specific detection of Ethyl Paraoxon and Methyl Parathion in water resources.
    Vyas T; Jaiswal S; Choudhary S; Kodgire P; Joshi A
    Environ Res; 2024 Feb; 243():117855. PubMed ID: 38070850
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The vital function of Fe3O4@Au nanocomposites for hydrolase biosensor design and its application in detection of methyl parathion.
    Zhao Y; Zhang W; Lin Y; Du D
    Nanoscale; 2013 Feb; 5(3):1121-6. PubMed ID: 23280070
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Direct, selective and ultrasensitive electrochemical biosensing of methyl parathion in vegetables using Burkholderia cepacia lipase@MOF nanofibers-based biosensor.
    Wang Z; Ma B; Shen C; Cheong LZ
    Talanta; 2019 May; 197():356-362. PubMed ID: 30771947
    [TBL] [Abstract][Full Text] [Related]  

  • 11. ELP-OPH/BSA/TiO2 nanofibers/c-MWCNTs based biosensor for sensitive and selective determination of p-nitrophenyl substituted organophosphate pesticides in aqueous system.
    Bao J; Hou C; Dong Q; Ma X; Chen J; Huo D; Yang M; Galil KHAE; Chen W; Lei Y
    Biosens Bioelectron; 2016 Nov; 85():935-942. PubMed ID: 27315519
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Methyl parathion hydrolase based nanocomposite biosensors for highly sensitive and selective determination of methyl parathion.
    Chen S; Huang J; Du D; Li J; Tu H; Liu D; Zhang A
    Biosens Bioelectron; 2011 Jul; 26(11):4320-5. PubMed ID: 21616655
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biosensor for direct determination of organophosphate nerve agents using recombinant Escherichia coli with surface-expressed organophosphorus hydrolase. 2. Fiber-optic microbial biosensor.
    Mulchandani A; Kaneva I; Chen W
    Anal Chem; 1998 Dec; 70(23):5042-6. PubMed ID: 9852785
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A novel biosensor-based method for the detection of p-nitrophenol in agricultural soil.
    Ma Z; Li Y; Lu Z; Pan J; Li M
    Chemosphere; 2023 Feb; 313():137306. PubMed ID: 36410515
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Covalent coupling of organophosphorus hydrolase loaded quantum dots to carbon nanotube/Au nanocomposite for enhanced detection of methyl parathion.
    Du D; Chen W; Zhang W; Liu D; Li H; Lin Y
    Biosens Bioelectron; 2010 Feb; 25(6):1370-5. PubMed ID: 19926466
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An engineered quorum-sensing-based whole-cell biosensor for active degradation of organophosphates.
    He J; Zhang X; Qian Y; Wang Q; Bai Y
    Biosens Bioelectron; 2022 Jun; 206():114085. PubMed ID: 35231682
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Flow injection biosensor based on the immobilized AChE].
    Zhu XS; Meng FP; Zhu L; He DH
    Huan Jing Ke Xue; 2006 Sep; 27(9):1829-34. PubMed ID: 17117641
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cloning of the organophosphorus pesticide hydrolase gene clusters of seven degradative bacteria isolated from a methyl parathion contaminated site and evidence of their horizontal gene transfer.
    Zhang R; Cui Z; Zhang X; Jiang J; Gu JD; Li S
    Biodegradation; 2006 Oct; 17(5):465-72. PubMed ID: 16477356
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Proteomic analysis of Burkholderia zhejiangensis CEIB S4-3 during the methyl parathion degradation process.
    Castrejón-Godínez ML; Tovar-Sánchez E; Ortiz-Hernández ML; Encarnación-Guevara S; Martínez-Batallar ÁG; Hernández-Ortiz M; Sánchez-Salinas E; Rodríguez A; Mussali-Galante P
    Pestic Biochem Physiol; 2022 Oct; 187():105197. PubMed ID: 36127069
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An optical microplate biosensor for the detection of methyl parathion pesticide using a biohybrid of Sphingomonas sp. cells-silica nanoparticles.
    Mishra A; Kumar J; Melo JS
    Biosens Bioelectron; 2017 Jan; 87():332-338. PubMed ID: 27573300
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.