BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 3760483)

  • 21. Validation of Respiratory Inductance Plethysmography for Measuring Tidal Volume in Swine.
    Su Z; Oto J; Wang J; Kimball WR; Chenelle CT; Kacmarek RM; King DR; Jiang Y; Duggan MJ
    Comp Med; 2015 Jun; 65(3):225-31. PubMed ID: 26141447
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Measurement of ventilation in children using the respiratory inductive plethysmograph.
    Tabachnik E; Muller N; Toye B; Levison H
    J Pediatr; 1981 Dec; 99(6):895-9. PubMed ID: 7310582
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Respiratory inductive plethysmography as a method for measuring ventilatory parameters in conscious, non-restrained dogs.
    Murphy DJ; Renninger JP; Schramek D
    J Pharmacol Toxicol Methods; 2010; 62(1):47-53. PubMed ID: 20435149
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Inductive plethysmography--a facilitated postural calibration technique for rapid and accurate tidal volume determination in low birth weight premature newborns.
    Stefano JL; Spitzer AR; Baumgart S; Davis JM; Fox WW
    Am Rev Respir Dis; 1986 Nov; 134(5):1020-4. PubMed ID: 3777664
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Measurement of total and compartmental lung volume changes in newborns by optoelectronic plethysmography.
    Dellaca' RL; Ventura ML; Zannin E; Natile M; Pedotti A; Tagliabue P
    Pediatr Res; 2010 Jan; 67(1):11-6. PubMed ID: 19755932
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Respiratory inductance plethysmography: calibration techniques, their validation and the effects of posture.
    Stradling JR; Chadwick GA; Quirk C; Phillips T
    Bull Eur Physiopathol Respir; 1985; 21(4):317-24. PubMed ID: 4041657
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Accuracy of ventilatory measurement employing ambulatory inductive plethysmography during tasks of everyday life.
    Grossman P; Wilhelm FH; Brutsche M
    Biol Psychol; 2010 Apr; 84(1):121-8. PubMed ID: 20176075
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Calibration of computer-assisted (Respicomp) respiratory inductive plethysmography in newborns.
    Warren RH; Alderson SH
    Am Rev Respir Dis; 1985 Apr; 131(4):564-7. PubMed ID: 3838868
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Early experience with remote pressure sensor respiratory plethysmography monitoring sedation in the MR scanner.
    Caldiroli D; Minati L
    Eur J Anaesthesiol; 2007 Sep; 24(9):761-9. PubMed ID: 17517150
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Mathematical assessment of qualitative diagnostic calibration for respiratory inductive plethysmography.
    De Groote A; Paiva M; Verbandt Y
    J Appl Physiol (1985); 2001 Mar; 90(3):1025-30. PubMed ID: 11181615
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of respiratory inductive plethysmography in infants weighing less than 1,500 grams.
    Wilkes DL; Revow M; Bryan MH; England SJ
    Am Rev Respir Dis; 1987 Aug; 136(2):416-9. PubMed ID: 3619201
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Nonlinear model for estimating respiratory volume based on thoracoabdominal breathing movements.
    Raoufy MR; Hajizadeh S; Gharibzadeh S; Mani AR; Eftekhari P; Masjedi MR
    Respirology; 2013 Jan; 18(1):108-16. PubMed ID: 22897148
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The effect of breath size and posture on calibration of the respiratory inductive plethysmograph by multiple linear regression.
    Verschakelen JA; Deschepper K; Clarysse I; Demedts M
    Eur Respir J; 1989 Jan; 2(1):71-7. PubMed ID: 2707404
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Respiratory inductive plethysmography accuracy at varying PEEP levels and degrees of acute lung injury.
    Markhorst DG; Van Gestel JP; Van Genderingen HR; Haitsma JJ; Lachmann B; Van Vught AJ
    J Med Eng Technol; 2006; 30(3):166-75. PubMed ID: 16772220
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Validation of respiratory inductive plethysmography using the Qualitative Diagnostic Calibration method in anaesthetized infants.
    Brown K; Aun C; Jackson E; Mackersie A; Hatch D; Stocks J
    Eur Respir J; 1998 Oct; 12(4):935-43. PubMed ID: 9817172
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of the respiratory inductive plethysmograph in man.
    Guyatt AR; McBride MJ; Meanock CI
    Eur J Respir Dis; 1983 Feb; 64(2):81-9. PubMed ID: 6832253
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Accuracy of the respiratory inductive plethysmograph during loaded breathing.
    Tobin MJ; Guenther SM; Perez W; Mador MJ
    J Appl Physiol (1985); 1987 Feb; 62(2):497-505. PubMed ID: 3558209
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Error analysis of a natural breathing calibration method for respiratory inductive plethysmography.
    Strömberg NO
    Med Biol Eng Comput; 2001 May; 39(3):310-4. PubMed ID: 11465885
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Validation of respiratory inductive plethysmography in patients with pulmonary disease.
    Tobin MJ; Jenouri G; Lind B; Watson H; Schneider A; Sackner MA
    Chest; 1983 Apr; 83(4):615-20. PubMed ID: 6831949
    [TBL] [Abstract][Full Text] [Related]  

  • 40. An inexpensive, MRI compatible device to measure tidal volume from chest-wall circumference.
    Binks AP; Banzett RB; Duvivier C
    Physiol Meas; 2007 Feb; 28(2):149-59. PubMed ID: 17237587
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.