These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
152 related articles for article (PubMed ID: 37609044)
21. Feasibility of Quantitative MRI Using 3D-QALAS for Discriminating Immunohistochemical Status in Invasive Ductal Carcinoma of the Breast. Amano M; Fujita S; Takei N; Sano K; Wada A; Sato K; Kikuta J; Kuwatsuru Y; Tachibana R; Sekine T; Horimoto Y; Aoki S J Magn Reson Imaging; 2023 Dec; 58(6):1752-1759. PubMed ID: 36951614 [TBL] [Abstract][Full Text] [Related]
22. Clinical application of single-shot echo-planar diffusion-weighted imaging with compressed SENSE in prostate MRI at 3T: preliminary experience. Tamada T; Ueda Y; Kido A; Yoneyama M; Takeuchi M; Sanai H; Ono K; Yamamoto A; Sone T MAGMA; 2022 Aug; 35(4):549-556. PubMed ID: 35403993 [TBL] [Abstract][Full Text] [Related]
23. Intravoxel Incoherent Motion Diffusion-Weighted Imaging of Lung Cancer: Comparison Between Turbo Spin-Echo and Echo-Planar Imaging. Wan Q; Lei Q; Wang P; Hu J; Zhang T; Yu D; Li X; Liang C J Comput Assist Tomogr; 2020; 44(3):334-340. PubMed ID: 32217894 [TBL] [Abstract][Full Text] [Related]
24. Preliminary Experience of 5.0 T Higher Field Abdominal Diffusion-Weighted MRI: Agreement of Apparent Diffusion Coefficient With 3.0 T Imaging. Zhang Y; Yang C; Liang L; Shi Z; Zhu S; Chen C; Dai Y; Zeng M J Magn Reson Imaging; 2022 Oct; 56(4):1009-1017. PubMed ID: 35119776 [TBL] [Abstract][Full Text] [Related]
25. SSL-QALAS: Self-Supervised Learning for rapid multiparameter estimation in quantitative MRI using 3D-QALAS. Jun Y; Cho J; Wang X; Gee M; Grant PE; Bilgic B; Gagoski B Magn Reson Med; 2023 Nov; 90(5):2019-2032. PubMed ID: 37415389 [TBL] [Abstract][Full Text] [Related]
26. Reproducibility and feasibility of optic nerve diffusion MRI techniques: single-shot echo-planar imaging (EPI), readout-segmented EPI, and reduced field-of-view diffusion-weighted imaging. Zhou F; Li Q; Zhang X; Ma H; Zhang G; Du S; Zhang L; Benkert T; Zhang Z BMC Med Imaging; 2022 May; 22(1):96. PubMed ID: 35606748 [TBL] [Abstract][Full Text] [Related]
27. Reproducibility of measurement of apparent diffusion coefficients of malignant hepatic tumors: effect of DWI techniques and calculation methods. Kim SY; Lee SS; Park B; Kim N; Kim JK; Park SH; Byun JH; Song KJ; Koo JH; Choi EK; Lee MG J Magn Reson Imaging; 2012 Nov; 36(5):1131-8. PubMed ID: 22777895 [TBL] [Abstract][Full Text] [Related]
28. Repeatability quantification of brain diffusion-weighted imaging for future clinical implementation at a low-field MR-linac. Rabe M; Dietrich O; Forbrig R; Niyazi M; Belka C; Corradini S; Landry G; Kurz C Radiat Oncol; 2024 Mar; 19(1):31. PubMed ID: 38448888 [TBL] [Abstract][Full Text] [Related]
29. Radiomics in diffusion data: a test-retest, inter- and intra-reader DWI phantom study. Dreher C; Kuder TA; König F; Mlynarska-Bujny A; Tenconi C; Paech D; Schlemmer HP; Ladd ME; Bickelhaupt S Clin Radiol; 2020 Oct; 75(10):798.e13-798.e22. PubMed ID: 32723501 [TBL] [Abstract][Full Text] [Related]
30. Clinical feasibility of 3D-QALAS - Single breath-hold 3D myocardial T1- and T2-mapping. Kvernby S; Warntjes M; Engvall J; Carlhäll CJ; Ebbers T Magn Reson Imaging; 2017 May; 38():13-20. PubMed ID: 27998745 [TBL] [Abstract][Full Text] [Related]
31. Diffusion-weighted MRI of the lung at 3T evaluated using echo-planar-based and single-shot turbo spin-echo-based acquisition techniques for radiotherapy applications. Tyagi N; Cloutier M; Zakian K; Deasy JO; Hunt M; Rimner A J Appl Clin Med Phys; 2019 Jan; 20(1):284-292. PubMed ID: 30421496 [TBL] [Abstract][Full Text] [Related]
32. Comparing the clinical utility of single-shot, readout-segmented and zoomit echo-planar imaging in diffusion-weighted imaging of the kidney at 3 T. Liu W; Liu H; Xie S; Masokano IB; Bai Y; Wang X; Zhong L; Wu Y; Nie J; Zhou G; Pei Y; Li W Sci Rep; 2022 Jul; 12(1):12389. PubMed ID: 35859112 [TBL] [Abstract][Full Text] [Related]
33. Accelerated Breast Diffusion-weighted Imaging Using Multiband Sensitivity Encoding with the CAIPIRINHA Method: Clinical Experience at 3 T. Biswas D; Hippe DS; Wang Y; DelPriore MR; Zečević M; Scheel JR; Rahbar H; Partridge SC Radiol Imaging Cancer; 2022 Jan; 4(1):e210063. PubMed ID: 35029517 [TBL] [Abstract][Full Text] [Related]
35. Values of Apparent Diffusion Coefficient and Lesion-to-Spinal Cord Signal Intensity in Diagnosing Solitary Pulmonary Lesions: Turbo Spin-Echo versus Echo-Planar Imaging Diffusion-Weighted Imaging. Lei Q; Wan Q; Liu L; Hu J; Zuo W; Li J; Jiang G; Li X Biomed Res Int; 2021; 2021():3345953. PubMed ID: 34435042 [TBL] [Abstract][Full Text] [Related]
36. Multiparametric Mapping Magnetic Resonance Imaging of Pancreatic Disease. Wang L; Gaddam S; Wang N; Xie Y; Deng Z; Zhou Z; Fan Z; Jiang T; Christodoulou AG; Han F; Lo SK; Wachsman AM; Hendifar AE; Pandol SJ; Li D Front Physiol; 2020; 11():8. PubMed ID: 32153416 [TBL] [Abstract][Full Text] [Related]
37. Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla. Xie S; Masokano IB; Liu W; Long X; Li G; Pei Y; Li W Eur J Radiol; 2021 Feb; 135():109472. PubMed ID: 33370640 [TBL] [Abstract][Full Text] [Related]
38. Brain fetal magnetic resonance imaging to evaluate maturation of normal white matter during the third trimester of pregnancy. Letissier C; Crombé A; Chérier L; Delmas J; Chateil JF Pediatr Radiol; 2021 Sep; 51(10):1826-1838. PubMed ID: 34019102 [TBL] [Abstract][Full Text] [Related]
39. Analysis of Apparent Diffusion Coefficients of the Brain in Healthy Controls: A Comparison Study between Single-Shot Echo-Planar Imaging and Read-out-Segmented Echo-Planar Imaging. Choi Y; Hwang EJ; Nam Y; Choi HS; Jang J; Jung SL; Ahn KJ; Kim BS Korean J Radiol; 2019 Jul; 20(7):1138-1145. PubMed ID: 31270977 [TBL] [Abstract][Full Text] [Related]
40. Solid bone tumors of the spine: Diagnostic performance of apparent diffusion coefficient measured using diffusion-weighted MRI using histology as a reference standard. Pozzi G; Albano D; Messina C; Angileri SA; Al-Mnayyis A; Galbusera F; Luzzati A; Perrucchini G; Scotto G; Parafioriti A; Zerbi A; Sconfienza LM J Magn Reson Imaging; 2018 Apr; 47(4):1034-1042. PubMed ID: 28755383 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]