These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
134 related articles for article (PubMed ID: 37609515)
21. CT automated exposure control using a generalized detectability index. Khobragade P; Rupcich F; Fan J; Crotty DJ; Kulkarni NM; O'Connor SD; Foley WD; Schmidt TG Med Phys; 2019 Jan; 46(1):140-151. PubMed ID: 30417403 [TBL] [Abstract][Full Text] [Related]
22. Effect of x-ray tube parameters and iodine concentration on image quality and radiation dose in cerebral pediatric and adult CT angiography: a phantom study. Papadakis AE; Perisinakis K; Raissaki M; Damilakis J Invest Radiol; 2013 Apr; 48(4):192-9. PubMed ID: 23344518 [TBL] [Abstract][Full Text] [Related]
23. Quantification and homogenization of image noise between two CT scanner models. Einstein SA; Rong XJ; Jensen CT; Liu X J Appl Clin Med Phys; 2020 Jan; 21(1):174-178. PubMed ID: 31859454 [TBL] [Abstract][Full Text] [Related]
24. Three-dimensional printing of patient-specific lung phantoms for CT imaging: Emulating lung tissue with accurate attenuation profiles and textures. Mei K; Geagan M; Roshkovan L; Litt HI; Gang GJ; Shapira N; Stayman JW; Noël PB Med Phys; 2022 Feb; 49(2):825-835. PubMed ID: 34910309 [TBL] [Abstract][Full Text] [Related]
25. Algorithm development for automatic laser alignment assessment on an ACR CT phantom and its evaluation on sixteen CT scanners. Anam C; Amilia R; Naufal A; Dougherty G Biomed Phys Eng Express; 2023 Oct; 9(6):. PubMed ID: 37788647 [No Abstract] [Full Text] [Related]
26. Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective. Brady SL; Yee BS; Kaufman RA Med Phys; 2012 Sep; 39(9):5520-31. PubMed ID: 22957619 [TBL] [Abstract][Full Text] [Related]
27. The influence of focal spot blooming on high-contrast spatial resolution in CT imaging. Grimes J; Duan X; Yu L; Halaweish AF; Haag N; Leng S; McCollough C Med Phys; 2015 Oct; 42(10):6011-20. PubMed ID: 26429276 [TBL] [Abstract][Full Text] [Related]
28. Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner. Goodsitt MM; Christodoulou EG; Larson SC Med Phys; 2011 Apr; 38(4):2222-32. PubMed ID: 21626956 [TBL] [Abstract][Full Text] [Related]
29. Volumetry of low-contrast liver lesions with CT: Investigation of estimation uncertainties in a phantom study. Li Q; Liang Y; Huang Q; Zong M; Berman B; Gavrielides MA; Schwartz LH; Zhao B; Petrick N Med Phys; 2016 Dec; 43(12):6608. PubMed ID: 27908157 [TBL] [Abstract][Full Text] [Related]
30. Cone-beam CT dose and imaging performance evaluation with a modular, multipurpose phantom. Siewerdsen JH; Uneri A; Hernandez AM; Burkett GW; Boone JM Med Phys; 2020 Feb; 47(2):467-479. PubMed ID: 31808950 [TBL] [Abstract][Full Text] [Related]
31. Deep learning image reconstruction for quality assessment of iodine concentration in computed tomography: A phantom study. Jeon PH; Lee CL J Xray Sci Technol; 2023; 31(2):409-422. PubMed ID: 36744361 [TBL] [Abstract][Full Text] [Related]
32. A methodology for image quality evaluation of advanced CT systems. Wilson JM; Christianson OI; Richard S; Samei E Med Phys; 2013 Mar; 40(3):031908. PubMed ID: 23464323 [TBL] [Abstract][Full Text] [Related]
33. Performance evaluation of a micro-CT system for laboratory animal imaging with iterative reconstruction capabilities. Muller FM; Vanhove C; Vandeghinste B; Vandenberghe S Med Phys; 2022 May; 49(5):3121-3133. PubMed ID: 35170057 [TBL] [Abstract][Full Text] [Related]
34. Stenosis quantification in coronary CT angiography: impact of an integrated circuit detector with iterative reconstruction. Morsbach F; Desbiolles L; Plass A; Leschka S; Schmidt B; Falk V; Alkadhi H; Stolzmann P Invest Radiol; 2013 Jan; 48(1):32-40. PubMed ID: 23192163 [TBL] [Abstract][Full Text] [Related]
35. Thermoplastic 3D printing technology using a single filament for producing realistic patient-derived breast models. Dukov N; Bliznakova K; Okkalidis N; Teneva T; Encheva E; Bliznakov Z Phys Med Biol; 2022 Feb; 67(4):. PubMed ID: 35038693 [No Abstract] [Full Text] [Related]
36. Evaluating the effects of variation in CT scanning parameters on the image quality and Hounsfield units for optimization of dose in radiotherapy treatment planning: A semi-anthropomorphic thorax phantom study. Sorooshfard E; Tahmasbi M; Chegeni N; Tahmasebi Birgani MJ J Cancer Res Ther; 2023; 19(2):426-434. PubMed ID: 37006077 [TBL] [Abstract][Full Text] [Related]
37. Adaptive nonlocal means filtering based on local noise level for CT denoising. Li Z; Yu L; Trzasko JD; Lake DS; Blezek DJ; Fletcher JG; McCollough CH; Manduca A Med Phys; 2014 Jan; 41(1):011908. PubMed ID: 24387516 [TBL] [Abstract][Full Text] [Related]
38. Reliability of Skeletal Muscle Area Measurement on CT with Different Parameters: A Phantom Study. Kim DW; Ha J; Ko Y; Kim KW; Park T; Lee J; You MW; Yoon KH; Park JY; Kee YJ; Kim HK Korean J Radiol; 2021 Apr; 22(4):624-633. PubMed ID: 33569929 [TBL] [Abstract][Full Text] [Related]
39. How does c-view image quality compare with conventional 2D FFDM? Nelson JS; Wells JR; Baker JA; Samei E Med Phys; 2016 May; 43(5):2538. PubMed ID: 27147364 [TBL] [Abstract][Full Text] [Related]
40. Radiation dose reduction to the breast in thoracic CT: comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current. Wang J; Duan X; Christner JA; Leng S; Yu L; McCollough CH Med Phys; 2011 Nov; 38(11):6084-92. PubMed ID: 22047373 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]