BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

205 related articles for article (PubMed ID: 37615718)

  • 61. Gait analysis of fixed bearing and mobile bearing total knee prostheses during walking: do mobile bearings offer functional advantages?
    Urwin SG; Kader DF; Caplan N; St Clair Gibson A; Stewart S
    Knee; 2014 Mar; 21(2):391-5. PubMed ID: 24238651
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Valgus position of the femoral component causes abnormal kinematics in the presence of medial looseness in total knee arthroplasty: a computer simulation model of TKA for valgus knee osteoarthritis.
    Nishitani K; Kuriyama S; Nakamura S; Morita Y; Ito H; Matsuda S
    Knee Surg Sports Traumatol Arthrosc; 2019 Jul; 27(7):2051-2060. PubMed ID: 30374567
    [TBL] [Abstract][Full Text] [Related]  

  • 63. The higher patient-reported outcome measure group had smaller external rotation of the femur in bicruciate-stabilized total knee arthroplasty.
    Kono K; Inui H; Tomita T; Yamazaki T; Taketomi S; Yamagami R; Kawaguchi K; Tanaka S
    Knee Surg Sports Traumatol Arthrosc; 2022 Apr; 30(4):1292-1299. PubMed ID: 33864115
    [TBL] [Abstract][Full Text] [Related]  

  • 64. No difference in patellar position between mobile-bearing and fixed-bearing total knee arthroplasty for medial osteoarthritis: a prospective randomized study.
    Sappey-Marinier E; de Abreu FGA; O'Loughlin P; Gaillard R; Neyret P; Lustig S; Servien E
    Knee Surg Sports Traumatol Arthrosc; 2020 May; 28(5):1542-1550. PubMed ID: 31218390
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Matched comparison of kinematics in knees with mild and severe varus deformity using fixed- and mobile-bearing total knee arthroplasty.
    Watanabe T; Ishizuki M; Muneta T; Banks SA
    Clin Biomech (Bristol, Avon); 2012 Nov; 27(9):924-8. PubMed ID: 22835859
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations.
    Harman MK; Banks SA; Kirschner S; Lützner J
    BMC Musculoskelet Disord; 2012 Oct; 13():206. PubMed ID: 23088451
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Ball-in-socket medial conformity with posterior cruciate ligament retention neither limits internal tibial rotation and knee flexion nor lowers clinical outcome scores after unrestricted kinematically aligned total knee arthroplasty.
    Elorza SP; O'Donnell E; Nedopil A; Howell SM; Hull ML
    Int Orthop; 2023 Jul; 47(7):1737-1746. PubMed ID: 37195465
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Kinematic alignment technique for medial OXFORD UKA: An in-silico study.
    Rivière C; Harman C; Leong A; Cobb J; Maillot C
    Orthop Traumatol Surg Res; 2019 Feb; 105(1):63-70. PubMed ID: 30595413
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Fixed-bearing unicompartmental knee arthroplasty tolerates higher variance in tibial implant rotation than mobile-bearing designs.
    Ozcan C; Simsek ME; Tahta M; Akkaya M; Gursoy S; Bozkurt M
    Arch Orthop Trauma Surg; 2018 Oct; 138(10):1463-1469. PubMed ID: 30027484
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Kinematic Performance of Medial Pivot Total Knee Arthroplasty.
    Hamilton LD; Shelburne KB; Rullkoetter PJ; Barnes CL; Mannen EM
    J Arthroplasty; 2024 Jun; 39(6):1595-1601.e7. PubMed ID: 38061399
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Limited effect of anatomical insert geometry on in vitro laxity in balanced anatomic posterior cruciate ligament retaining total knee arthroplasty.
    van Houten AH; Heesterbeek PJC; Hannink G; Labey L; Wymenga AB
    Knee Surg Sports Traumatol Arthrosc; 2022 Apr; 30(4):1273-1281. PubMed ID: 33860338
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Joint awareness after fixed and mobile-bearing total knee arthroplasty with minimum 12 years of follow-up: A propensity matched-pair analysis.
    Bakircioglu S; Aksoy T; Caglar O; Mazhar Tokgozoglu A; Atilla B
    Knee; 2023 Jun; 42():130-135. PubMed ID: 37001329
    [TBL] [Abstract][Full Text] [Related]  

  • 73. A constrained-condylar fixed-bearing total knee arthroplasty is stabilised by the medial soft tissues.
    Athwal KK; Willinger L; Manning W; Deehan D; Amis AA
    Knee Surg Sports Traumatol Arthrosc; 2021 Feb; 29(2):659-667. PubMed ID: 32322947
    [TBL] [Abstract][Full Text] [Related]  

  • 74. New mobile-bearing TKA with unique ball and socket post-cam mechanism offers similar function and stability with better prosthesis fit and gap balancing compared to an established fixed-bearing prosthesis.
    Tiwari V; Meshram P; Park CK; Bansal V; Kim TK
    Knee Surg Sports Traumatol Arthrosc; 2019 Jul; 27(7):2145-2154. PubMed ID: 30810785
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Characteristic kinematics of floor-sitting activities after posterior-stabilized total knee arthroplasty determined using model-based shape-matching techniques.
    Watanabe T; Gamada K; Koga H; Sekiya I; Muneta T; Jinno T
    Knee; 2021 Mar; 29():571-579. PubMed ID: 33602618
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Low tibial baseplate migration 1 year after unrestricted kinematically aligned total knee arthroplasty using a medial conforming implant design.
    Niesen AE; Garverick AL; Howell SM; Hull ML
    Knee Surg Sports Traumatol Arthrosc; 2023 Apr; 31(4):1433-1442. PubMed ID: 36201009
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Medial congruent polyethylene design show different tibiofemoral kinematics and enhanced congruency compared to a standard symmetrical cruciate retaining design for total knee arthroplasty-an in vivo randomized controlled study of gait using dynamic radiostereometry.
    Petersen ET; Rytter S; Koppens D; Dalsgaard J; Hansen TB; Andersen MS; Stilling M
    Knee Surg Sports Traumatol Arthrosc; 2023 Mar; 31(3):933-945. PubMed ID: 35809105
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Mobile-bearing total knee arthroplasty: More rotation is evident during more demanding tasks.
    Zürcher AW; van Hutten K; Harlaar J; Terwee CB; Rob Albers GH; Pöll RG
    Knee; 2014 Oct; 21(5):960-3. PubMed ID: 24950996
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Equal tibial component fixation of a mobile-bearing and fixed-bearing medial unicompartmental knee arthroplasty: a randomized controlled RSA study with 2-year follow-up.
    Koppens D; Rytter S; Munk S; Dalsgaard J; Sørensen OG; Hansen TB; Stilling M
    Acta Orthop; 2019 Dec; 90(6):575-581. PubMed ID: 31293193
    [TBL] [Abstract][Full Text] [Related]  

  • 80. No differences between fixed- and mobile-bearing total knee arthroplasty.
    Fransen BL; van Duijvenbode DC; Hoozemans MJM; Burger BJ
    Knee Surg Sports Traumatol Arthrosc; 2017 Jun; 25(6):1757-1777. PubMed ID: 27324479
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.