These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

57 related articles for article (PubMed ID: 3763017)

  • 1. Boiled and unboiled detached autogenous bone fragments--an experimental study.
    Stroosma OC; Klopper PJ; van den Hooff A
    Neth J Surg; 1986 Aug; 38(4):112-7. PubMed ID: 3763017
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bacterially contaminated detached autogenous bone fragments--an experimental study.
    Stroosma OC; Klopper PJ; van den Hooff A
    Neth J Surg; 1986 Aug; 38(4):118-20. PubMed ID: 3763018
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Open reduction and internal fixation of distal femoral nonunions: long-term functional outcomes following a treatment protocol.
    Gardner MJ; Toro-Arbelaez JB; Harrison M; Hierholzer C; Lorich DG; Helfet DL
    J Trauma; 2008 Feb; 64(2):434-8. PubMed ID: 18301211
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of stable fixation on trabecular bone healing: a morphologic assessment in dogs.
    Uhthoff HK; Goto S; Cerckel PH
    J Orthop Res; 1987; 5(1):14-22. PubMed ID: 3819907
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Resorption of bone tissue when titanium fixators are used].
    Sherepo KM
    Med Tekh; 1998; (4):10-5. PubMed ID: 9791848
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Treatment of traumatic bone defect with graft material of allogenic cancellous combined with autologous red marrow].
    Kong Z; Tian D; Yu H; Feng W; Liu C
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Oct; 22(10):1251-4. PubMed ID: 18979889
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Early results with the new internal fixator systems LCP and LISS: a prospective study.
    Hernanz González Y; Díaz Martín A; Jara Sánchez F; Resines Erasun C
    Acta Orthop Belg; 2007 Feb; 73(1):60-9. PubMed ID: 17441660
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of delayed internal fixation on healing of the osteotomized dog radius.
    Coutts RD; Woo SL; Boyer J; Doty D; Gonsalves M; Amiel D; Akeson WH
    Clin Orthop Relat Res; 1982 Mar; (163):254-60. PubMed ID: 7067260
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Osteosynthesis in dislocated femoral neck fracture (Garden 3 and 4). Long-term results and treatment concept].
    Fehr HR; Steiner W; Noesberger B
    Helv Chir Acta; 1993 Mar; 59(4):539-42. PubMed ID: 8473165
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Locking compression plate with minimally invasive plate osteosynthesis in diaphyseal and distal tibial fracture: a retrospective study of 32 patients.
    Hasenboehler E; Rikli D; Babst R
    Injury; 2007 Mar; 38(3):365-70. PubMed ID: 17241634
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [The effect of hydroxylapatite coating of AO/ASIF screws on bonding strength in bones].
    Dávid A; Pommer A; Eitenmüller J; Muhr G
    Unfallchirurg; 1993 Jan; 96(1):12-7. PubMed ID: 8382378
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Volar fixation for dorsally angulated extra-articular fractures of the distal radius: a biomechanical study.
    Koh S; Morris RP; Patterson RM; Kearney JP; Buford WL; Viegas SF
    J Hand Surg Am; 2006; 31(5):771-9. PubMed ID: 16713841
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Primary and secondary healing of bone fractures].
    Willenegger H; Perren SM; Schenk R
    Chirurg; 1971 Jun; 42(6):241-52. PubMed ID: 4104342
    [No Abstract]   [Full Text] [Related]  

  • 14. Experimental studies on the effect of osteotomy technique on the bone regeneration in distraction osteogenesis.
    Krawczyk A; Kuropka P; Kuryszko J; Wall A; Dragan S; Kulej M
    Bone; 2007 Mar; 40(3):781-91. PubMed ID: 17140872
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate.
    Arora R; Lutz M; Hennerbichler A; Krappinger D; Espen D; Gabl M
    J Orthop Trauma; 2007 May; 21(5):316-22. PubMed ID: 17485996
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [An experimental study of the effects of stress-relaxation plate on bone remodeling].
    Dai M; Dai K; Qui S
    Zhonghua Wai Ke Za Zhi; 1995 Nov; 33(11):698-700. PubMed ID: 8731919
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison analysis of the operative treatment results of the femoral neck fractures using side-plate and compression screw and cannulated AO screws.
    Stiasny J; Dragan S; Kulej M; Martynkiewicz J; Płochowski J; Dragan SŁ
    Ortop Traumatol Rehabil; 2008; 10(4):350-61. PubMed ID: 18779768
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of drill cooling and bone structure on IMZ implant fixation.
    Haider R; Watzek G; Plenk H
    Int J Oral Maxillofac Implants; 1993; 8(1):83-91. PubMed ID: 8468088
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An experimental study of devices for internal fixation of distal femoral fractures.
    Kolmert L; Persson BM; Romanus B
    Clin Orthop Relat Res; 1982; (171):290-9. PubMed ID: 7140081
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Secondary internal osteosynthesis after external fixation for recent or old open fracture of the lower limb].
    Bernat M; Lecoq C; Lempidakis M; Martin G; Aswad R; Poitout DG
    Rev Chir Orthop Reparatrice Appar Mot; 1996; 82(2):137-44. PubMed ID: 8761099
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.