185 related articles for article (PubMed ID: 37632483)
21. Transcatheter Valve-in-Valve Implantation With a Novel Balloon-Expandable Device in Patients With Bioprosthetic Heart Valve Failure: A Case Series.
Ielasi A; Buono A; Medda M; Casilli F; Bande M; Pellicano M; Glauber M; Donatelli F; Tespili M
Cardiovasc Revasc Med; 2021 Jul; 28S():98-101. PubMed ID: 33250405
[TBL] [Abstract][Full Text] [Related]
22. Intentional bioprosthetic tricuspid valve fracture to facilitate transcatheter valve-in-valve deployment.
Karahalios B; Breinholt JP; Little SH; Huie Lin C
Catheter Cardiovasc Interv; 2021 Feb; 97(2):361-364. PubMed ID: 32141679
[TBL] [Abstract][Full Text] [Related]
23. Bioprosthetic valve fracture: Technical insights from a multicenter study.
Allen KB; Chhatriwalla AK; Saxon JT; Cohen DJ; Nguyen TC; Webb J; Loyalka P; Bavry AA; Rovin JD; Whisenant B; Dvir D; Kennedy KF; Thourani V; Lee R;
J Thorac Cardiovasc Surg; 2019 Nov; 158(5):1317-1328.e1. PubMed ID: 30857820
[TBL] [Abstract][Full Text] [Related]
24. Mitral regurgitation in patients undergoing transcatheter aortic valve implantation for degenerated surgical aortic bioprosthesis: Insights from PARTNER 2 Valve-in-Valve Registry.
Murdoch DJ; Sathananthan J; Hensey M; Alu MC; Liu Y; Crowley A; Wood D; Cheung A; Ye J; Feldman T; Hahn RT; Jaber WA; Mack MJ; Malaisrie SC; Leon MB; Webb JG
Catheter Cardiovasc Interv; 2020 Oct; 96(4):981-986. PubMed ID: 32118351
[TBL] [Abstract][Full Text] [Related]
25. Practical Approach to Transcatheter Aortic Valve Implantation and Bioprosthetic Valve Fracture in a Failed Bioprosthetic Surgical Valve.
Vanhaverbeke M; De Backer O; Dubois C
J Interv Cardiol; 2022; 2022():9899235. PubMed ID: 35250395
[TBL] [Abstract][Full Text] [Related]
26. Transcatheter Aortic Valve-in-Valve Replacement for Degenerated Stentless Bioprosthetic Aortic Valves: Results of a Multicenter Retrospective Analysis.
Miller M; Snyder M; Horne BD; Harkness JR; Doty JR; Miner EC; Jones KW; O'Neal KR; Reid BB; Caine WT; Clayson SE; Lindley E; Gardner B; Connors RC; Bowles BJ; Whisenant BK
JACC Cardiovasc Interv; 2019 Jul; 12(13):1217-1226. PubMed ID: 31272667
[TBL] [Abstract][Full Text] [Related]
27. TAVR to Solve Perceval Sutureless Valve Migration.
López-Tejero S; Núñez-García JC; Antúnez-Muiños P; González-Calle D; Martín-Moreiras J; Diego-Nieto A; Rodríguez-Collado J; Herrero-Garibi J; Sánchez-Fernández PL; Cruz-González I
JACC Cardiovasc Interv; 2022 Mar; 15(6):e65-e67. PubMed ID: 35219616
[No Abstract] [Full Text] [Related]
28. Long-term outcomes of transcatheter valve-in-valve replacement for failed aortic bioprosthesis: A meta-analysis.
Abushouk AI; Saad AM; Isogai T; Shekhar S; Krishnaswamy A; Yun J; Kapadia SR
Catheter Cardiovasc Interv; 2022 Mar; 99(4):1370-1372. PubMed ID: 33555123
[No Abstract] [Full Text] [Related]
29. Transcatheter aortic valve-in-valve implantation for failed surgical bioprosthetic valves. A minimalist approach without contrast aortography or echocardiographic guidance.
Attinger-Toller A; Htun NM; Murdoch D; Perlman GY; Alenezi A; Sathananthan J; Blanke P; Leipsic J; Thompson C; Ye J; Cheung A; Wood D; Webb JG
Catheter Cardiovasc Interv; 2020 Jan; 95(1):45-53. PubMed ID: 31038290
[TBL] [Abstract][Full Text] [Related]
30. Emergency valve-in-valve transcatheter aortic valve replacement in a patient with degenerated bioprosthetic aortic stenosis and cardiogenic shock on veno-arterial extracorporeal membrane oxygenation.
Summers MR; Mick S; Kapadia SR; Krishnaswamy A
Catheter Cardiovasc Interv; 2018 Sep; 92(3):592-596. PubMed ID: 28296034
[TBL] [Abstract][Full Text] [Related]
31. Transcatheter Aortic Valve Replacement for Bioprosthetic Aortic Stenosis in Pregnancy.
Berry N; Sawlani N; Economy K; Shook D; Nyman C; Singh MN; Pelletier M; Sobieszczyk P; Kaneko T; Shah P
JACC Cardiovasc Interv; 2018 Oct; 11(19):e161-e162. PubMed ID: 30286865
[No Abstract] [Full Text] [Related]
32. Commentary: Should valve-in-valve transcatheter aortic valve replacement be first-line treatment for failed aortic bioprostheses?
Kang JJH; Tam DY; Fremes SE
J Thorac Cardiovasc Surg; 2022 May; 163(5):1800-1802. PubMed ID: 33610354
[No Abstract] [Full Text] [Related]
33. Valve-in-valve transcatheter aortic valve implantation: The issues behind crossing a bioprosthesis.
Vella C; Romano V; Di Maio S; Ancona MB; Castriota F; Vassileva A; Ferri L; Bellini B; Moroni F; Russo F; Ghizzoni G; Gentile D; Palmisano A; Agricola E; Esposito A; Chieffo A; Montorfano M
Cardiovasc Revasc Med; 2024 May; 62():85-94. PubMed ID: 38160130
[TBL] [Abstract][Full Text] [Related]
34. Fracture of small Mitroflow® aortic bioprosthesis following valve-in-valve transcatheter aortic valve replacement with ACURATE neo valve-From bench testing to clinical practice.
Amat-Santos IJ; Gutiérrez H; Sathananthan J; Webb JG
Catheter Cardiovasc Interv; 2020 Mar; 95(4):E120-E122. PubMed ID: 31140682
[TBL] [Abstract][Full Text] [Related]
35. Balloon Fracturing Valve-in-Valve: How to Do It and a Case Report of TAVR in a Rapid Deployment Prosthesis.
Saadi RP; Tagliari AP; Polanczyck CA; Ferreira Leal JC; Saadi EK
J Interv Cardiol; 2022; 2022():4368887. PubMed ID: 35600211
[TBL] [Abstract][Full Text] [Related]
36. Transcatheter valve-in-valve versus redo surgical aortic valve replacement for the treatment of degenerated bioprosthetic aortic valve: A systematic review and meta-analysis.
Tam DY; Vo TX; Wijeysundera HC; Dvir D; Friedrich JO; Fremes SE
Catheter Cardiovasc Interv; 2018 Dec; 92(7):1404-1411. PubMed ID: 30024102
[TBL] [Abstract][Full Text] [Related]
37. Meta-analysis comparing valve-in-valve TAVR and redo-SAVR in patients with degenerated bioprosthetic aortic valve.
Saleem S; Ullah W; Syed MA; Megaly M; Thalambedu N; Younas S; Zahid S; Alam M; Virani SS; Verma DR; Abdul-Waheed M; Fischman DL
Catheter Cardiovasc Interv; 2021 Nov; 98(5):940-947. PubMed ID: 34110684
[TBL] [Abstract][Full Text] [Related]
38. 3 Ways to Mitigate the Risk of Transcatheter Heart Valve Underexpansion and Dysfunction in Valve-in-Valve TAVR.
Beaupré F; Garot P
JACC Cardiovasc Interv; 2023 Mar; 16(5):527-529. PubMed ID: 36922037
[No Abstract] [Full Text] [Related]
39. Transcatheter aortic valve implantation in degenerated surgical aortic valves.
Tarantini G; Dvir D; Tang GHL
EuroIntervention; 2021 Oct; 17(9):709-719. PubMed ID: 34665140
[TBL] [Abstract][Full Text] [Related]
40. Assessment of Long-Term Structural Deterioration of Transcatheter Aortic Bioprosthetic Valves Using the New European Definition.
Durand E; Sokoloff A; Urena-Alcazar M; Chevalier B; Chassaing S; Didier R; Tron C; Litzler PY; Bouleti C; Himbert D; Hovasse T; Bar O; Avinée G; Iung B; Blanchard D; Gilard M; Cribier A; Lefevre T; Eltchaninoff H
Circ Cardiovasc Interv; 2019 Apr; 12(4):e007597. PubMed ID: 30998397
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]