These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Association of x-ray velocimetry (XV) ventilation analysis compared to spirometry. Kirkness JP; Dusting J; Eikelis N; Pirakalathanan P; DeMarco J; Shiao SL; Fouras A Front Med Technol; 2023; 5():1148310. PubMed ID: 37440838 [TBL] [Abstract][Full Text] [Related]
3. Noninvasive cardiac output measurement using partial carbon dioxide rebreathing is less accurate at settings of reduced minute ventilation and when spontaneous breathing is present. Tachibana K; Imanaka H; Takeuchi M; Takauchi Y; Miyano H; Nishimura M Anesthesiology; 2003 Apr; 98(4):830-7. PubMed ID: 12657842 [TBL] [Abstract][Full Text] [Related]
4. Pilot study of paediatric regional lung function assessment via X-ray velocimetry (XV) imaging in children with normal lungs and in children with cystic fibrosis. Bruorton M; Donnelley M; Goddard T; O'Connor A; Parsons D; Phillips J; Carson-Chahhoud K; Tai A BMJ Open; 2024 Feb; 14(2):e080034. PubMed ID: 38316593 [TBL] [Abstract][Full Text] [Related]
5. Assessment of regional ventilation and deformation using 4D-CT imaging for healthy human lungs during tidal breathing. Jahani N; Choi S; Choi J; Iyer K; Hoffman EA; Lin CL J Appl Physiol (1985); 2015 Nov; 119(10):1064-74. PubMed ID: 26316512 [TBL] [Abstract][Full Text] [Related]
6. Influence of end-expiratory level and tidal volume on gravitational ventilation distribution during tidal breathing in healthy adults. Schnidrig S; Casaulta C; Schibler A; Riedel T Eur J Appl Physiol; 2013 Mar; 113(3):591-8. PubMed ID: 22872368 [TBL] [Abstract][Full Text] [Related]
7. Abnormal dynamic ventilation function of COVID-19 survivors detected by pulmonary free-breathing proton MRI. Wang C; Li H; Xiao S; Li Z; Zhao X; Xie J; Ye C; Xia L; Lou X; Zhou X Eur Radiol; 2022 Aug; 32(8):5297-5307. PubMed ID: 35184219 [TBL] [Abstract][Full Text] [Related]
8. Pitot-tube flowmeter for quantification of airflow during sleep. Kirkness JP; Verma M; McGinley BM; Erlacher M; Schwartz AR; Smith PL; Wheatley JR; Patil SP; Amis TC; Schneider H Physiol Meas; 2011 Feb; 32(2):223-37. PubMed ID: 21178245 [TBL] [Abstract][Full Text] [Related]
9. Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements. Du K; Reinhardt JM; Christensen GE; Ding K; Bayouth JE Med Phys; 2013 Dec; 40(12):123504. PubMed ID: 24320544 [TBL] [Abstract][Full Text] [Related]
10. A non-invasive continuous and real-time volumetric monitoring in spontaneous breathing subjects based on bioimpedance-ExSpiron®Xi: a validation study in healthy volunteers. Gatti S; Rezoagli E; Madotto F; Foti G; Bellani G J Clin Monit Comput; 2024 Apr; 38(2):539-551. PubMed ID: 38238635 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of fractional regional ventilation using 4D-CT and effects of breathing maneuvers on ventilation. Mistry NN; Diwanji T; Shi X; Pokharel S; Feigenberg S; Scharf SM; D'Souza WD Int J Radiat Oncol Biol Phys; 2013 Nov; 87(4):825-31. PubMed ID: 24064319 [TBL] [Abstract][Full Text] [Related]
12. Unloadiing of the work of breathing by proportional assist ventilation in a lung model. Bigatello LM; Nishimura M; Imanaka H; Hess D; Kimball WR; Kacmarek RM Crit Care Med; 1997 Feb; 25(2):267-72. PubMed ID: 9034262 [TBL] [Abstract][Full Text] [Related]
13. Obesity, tidal volume, and pulmonary deposition of fine particulate matter in children with asthma. Afshar-Mohajer N; Wu TD; Shade R; Brigham E; Woo H; Wood M; Koehl R; Koehler K; Kirkness J; Hansel NN; Ramchandran G; McCormack MC Eur Respir J; 2022 Mar; 59(3):. PubMed ID: 34385268 [TBL] [Abstract][Full Text] [Related]
15. Four methods of measuring tidal volume during high-frequency oscillatory ventilation. Hager DN; Fuld M; Kaczka DW; Fessler HE; Brower RG; Simon BA Crit Care Med; 2006 Mar; 34(3):751-7. PubMed ID: 16505661 [TBL] [Abstract][Full Text] [Related]
16. Assessment of spontaneous breathing during pressure controlled ventilation with superimposed spontaneous breathing using respiratory flow signal analysis. Kreyer S; Baker WL; Scaravilli V; Linden K; Belenkiy SM; Necsoiu C; Muders T; Putensen C; Chung KK; Cancio LC; Batchinsky AI J Clin Monit Comput; 2021 Aug; 35(4):859-868. PubMed ID: 32535849 [TBL] [Abstract][Full Text] [Related]
17. Measurements of ventilation in freely ranging subjects. McCool FD; Paek D Res Rep Health Eff Inst; 1993 May; (59):1-17; discussion 57-69. PubMed ID: 8216969 [TBL] [Abstract][Full Text] [Related]
18. Intraoperative use of low volume ventilation to decrease postoperative mortality, mechanical ventilation, lengths of stay and lung injury in adults without acute lung injury. Guay J; Ochroch EA; Kopp S Cochrane Database Syst Rev; 2018 Jul; 7(7):CD011151. PubMed ID: 29985541 [TBL] [Abstract][Full Text] [Related]
19. [Standard technical specifications for methacholine chloride (Methacholine) bronchial challenge test (2023)]. ; ; Zhonghua Jie He He Hu Xi Za Zhi; 2024 Feb; 47(2):101-119. PubMed ID: 38309959 [TBL] [Abstract][Full Text] [Related]
20. A comparison of the effects of assist-control, SIMV, and SIMV with pressure support on ventilation, oxygen consumption, and ventilatory equivalent. Shelledy DC; Rau JL; Thomas-Goodfellow L Heart Lung; 1995; 24(1):67-75. PubMed ID: 7706102 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]