BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 37650968)

  • 21. Dental imaging in clinical photon-counting CT at a quarter of DVT dose.
    Sawall S; Maier J; Sen S; Gehrig H; Kim TS; Schlemmer HP; Schönberg SO; Kachelrieß M; Rütters M
    J Dent; 2024 Mar; 142():104859. PubMed ID: 38272436
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Dose-efficient assessment of trabecular microstructure using ultra-high-resolution photon-counting CT.
    Peña JA; Klein L; Maier J; Damm T; Schlemmer HP; Engelke K; Glüer CC; Kachelrieß M; Sawall S
    Z Med Phys; 2022 Nov; 32(4):403-416. PubMed ID: 35597742
    [TBL] [Abstract][Full Text] [Related]  

  • 23. 150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images.
    Leng S; Rajendran K; Gong H; Zhou W; Halaweish AF; Henning A; Kappler S; Baer M; Fletcher JG; McCollough CH
    Invest Radiol; 2018 Nov; 53(11):655-662. PubMed ID: 29847412
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Photon-counting CT allows better visualization of temporal bone structures in comparison with current generation multi-detector CT.
    Hermans R; Boomgaert L; Cockmartin L; Binst J; De Stefanis R; Bosmans H
    Insights Imaging; 2023 Jul; 14(1):112. PubMed ID: 37395919
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A systematic assessment of photon-counting CT for bone mineral density and microarchitecture quantifications.
    McCabe C; Sauer TJ; Zarei M; Segars WP; Samei E; Abadi E
    Proc SPIE Int Soc Opt Eng; 2023 Feb; 12463():. PubMed ID: 37125263
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Coronary CT Angiography with Photon-counting CT: First-In-Human Results.
    Si-Mohamed SA; Boccalini S; Lacombe H; Diaw A; Varasteh M; Rodesch PA; Dessouky R; Villien M; Tatard-Leitman V; Bochaton T; Coulon P; Yagil Y; Lahoud E; Erhard K; Riche B; Bonnefoy E; Rioufol G; Finet G; Bergerot C; Boussel L; Greffier J; Douek PC
    Radiology; 2022 May; 303(2):303-313. PubMed ID: 35166583
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Lung Cancer Screening Using Clinical Photon-Counting Detector Computed Tomography and Energy-Integrating-Detector Computed Tomography: A Prospective Patient Study.
    Inoue A; Johnson TF; Walkoff LA; Levin DL; Hartman TE; Burke KA; Rajendran K; Yu L; McCollough CH; Fletcher JG
    J Comput Assist Tomogr; 2023 Mar-Apr 01; 47(2):229-235. PubMed ID: 36573321
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Photon-Counting Computed Tomography for Coronary Stent Imaging: In Vitro Evaluation of 28 Coronary Stents.
    Petritsch B; Petri N; Weng AM; Petersilka M; Allmendinger T; Bley TA; Gassenmaier T
    Invest Radiol; 2021 Oct; 56(10):653-660. PubMed ID: 33867450
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Low-Dose High-Resolution Photon-Counting CT of the Lung: Radiation Dose and Image Quality in the Clinical Routine.
    Woeltjen MM; Niehoff JH; Michael AE; Horstmeier S; Moenninghoff C; Borggrefe J; Kroeger JR
    Diagnostics (Basel); 2022 Jun; 12(6):. PubMed ID: 35741251
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Prospective Multireader Evaluation of Photon-counting CT for Multiple Myeloma Screening.
    Schwartz FR; Vinson EN; Spritzer CE; Colglazier R; Samei E; French RJ; Said N; Waldman L; McCrum E
    Radiol Imaging Cancer; 2022 Nov; 4(6):e220073. PubMed ID: 36399038
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience.
    Rajendran K; Petersilka M; Henning A; Shanblatt E; Marsh J; Thorne J; Schmidt B; Flohr T; Fletcher J; McCollough C; Leng S
    Phys Med Biol; 2021 Oct; 66(20):. PubMed ID: 34271558
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Dental imaging using an ultra-high resolution photon-counting CT system.
    Ruetters M; Sen S; Gehrig H; Bruckner T; Kim TS; Lux CJ; Schlemmer HP; Heinze S; Maier J; Kachelrieß M; Sawall S
    Sci Rep; 2022 May; 12(1):7125. PubMed ID: 35504943
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Dual energy CT with photon counting and dual source systems: comparative evaluation.
    Atak H; Shikhaliev PM
    Phys Med Biol; 2015 Dec; 60(23):8949-75. PubMed ID: 26539971
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Photon-Counting Computed Tomography - Basic Principles, Potenzial Benefits, and Initial Clinical Experience.
    Stein T; Rau A; Russe MF; Arnold P; Faby S; Ulzheimer S; Weis M; Froelich MF; Overhoff D; Horger M; Hagen F; Bongers M; Nikolaou K; Schönberg SO; Bamberg F; Weiß J
    Rofo; 2023 Aug; 195(8):691-698. PubMed ID: 36863367
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Coronary stent imaging in photon counting computed Tomography: Optimization of reconstruction kernels in a phantom.
    Michael AE; Schoenbeck D; Becker-Assmann J; Niehoff JH; Flohr T; Schmidt B; Panknin C; Baer-Beck M; Hickethier T; Maintz D; Bunck AC; Borggrefe J; Wiemer M; Rudolph V; Kroeger JR
    Eur J Radiol; 2023 Sep; 166():110983. PubMed ID: 37480648
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Clinical Low Dose Photon Counting CT for the Detection of Urolithiasis: Evaluation of Image Quality and Radiation Dose.
    Niehoff JH; Carmichael AF; Woeltjen MM; Boriesosdick J; Lopez Schmidt I; Michael AE; Große Hokamp N; Piechota H; Borggrefe J; Kroeger JR
    Tomography; 2022 Jun; 8(4):1666-1675. PubMed ID: 35894003
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Influence of helical pitch and gantry rotation time on image quality and file size in ultrahigh-resolution photon-counting detector CT.
    Feldle P; Grunz JP; Huflage H; Kunz AS; Ergün S; Afat S; Gruschwitz P; Görtz L; Pennig L; Bley TA; Conrads N
    Sci Rep; 2024 Apr; 14(1):9358. PubMed ID: 38653758
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of ultrahigh and standard resolution photon-counting CT angiography of the femoral arteries in a continuously perfused in vitro model.
    Gruschwitz P; Hartung V; Ergün S; Peter D; Lichthardt S; Huflage H; Hendel R; Pannenbecker P; Augustin AM; Kunz AS; Feldle P; Bley TA; Grunz JP
    Eur Radiol Exp; 2023 Dec; 7(1):83. PubMed ID: 38110729
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [High-resolution volumetric computerized tomography of the lung: optimization of technique and image quality as a function of its clinical-diagnostic use and dose to the patient].
    Gavelli G; Giampalma E; Cenni M; Pierotti L; Cavina M; Bergamini C
    Radiol Med; 1998 Apr; 95(4):322-8. PubMed ID: 9676210
    [TBL] [Abstract][Full Text] [Related]  

  • 40. X-ray dark-field chest imaging for detection and quantification of emphysema in patients with chronic obstructive pulmonary disease: a diagnostic accuracy study.
    Willer K; Fingerle AA; Noichl W; De Marco F; Frank M; Urban T; Schick R; Gustschin A; Gleich B; Herzen J; Koehler T; Yaroshenko A; Pralow T; Zimmermann GS; Renger B; Sauter AP; Pfeiffer D; Makowski MR; Rummeny EJ; Grenier PA; Pfeiffer F
    Lancet Digit Health; 2021 Nov; 3(11):e733-e744. PubMed ID: 34711378
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.