BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 37651766)

  • 1. An unsupervised dual contrastive learning framework for scatter correction in cone-beam CT image.
    Wang T; Liu X; Dai J; Zhang C; He W; Liu L; Chan Y; He Y; Zhao H; Xie Y; Liang X
    Comput Biol Med; 2023 Oct; 165():107377. PubMed ID: 37651766
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images.
    Niu T; Sun M; Star-Lack J; Gao H; Fan Q; Zhu L
    Med Phys; 2010 Oct; 37(10):5395-406. PubMed ID: 21089775
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Planning CT-guided robust and fast cone-beam CT scatter correction using a local filtration technique.
    Cui H; Jiang X; Fang C; Zhu L; Yang Y
    Med Phys; 2021 Nov; 48(11):6832-6843. PubMed ID: 34662433
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multi-energy blended CBCT spectral imaging and scatter-decoupled material decomposition using a spectral modulator with flying focal spot (SMFFS).
    Deng Y; Zhou H; Wang Z; Wang AS; Gao H
    Med Phys; 2024 Apr; 51(4):2398-2412. PubMed ID: 38477717
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Empirical scatter correction: CBCT scatter artifact reduction without prior information.
    Trapp P; Maier J; Susenburger M; Sawall S; Kachelrieß M
    Med Phys; 2022 Jul; 49(7):4566-4584. PubMed ID: 35390181
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT).
    Jin JY; Ren L; Liu Q; Kim J; Wen N; Guan H; Movsas B; Chetty IJ
    Med Phys; 2010 Nov; 37(11):5634-44. PubMed ID: 21158275
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Image-domain shading correction for cone-beam CT without prior patient information.
    Fan Q; Lu B; Park JC; Niu T; Li JG; Liu C; Zhu L
    J Appl Clin Med Phys; 2015 Nov; 16(6):65-75. PubMed ID: 26699555
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Binary moving-blocker-based scatter correction in cone-beam computed tomography with width-truncated projections: proof of concept.
    Lee H; Fahimian BP; Xing L
    Phys Med Biol; 2017 Mar; 62(6):2176-2193. PubMed ID: 28079527
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Projection-domain scatter correction for cone beam computed tomography using a residual convolutional neural network.
    Nomura Y; Xu Q; Shirato H; Shimizu S; Xing L
    Med Phys; 2019 Jul; 46(7):3142-3155. PubMed ID: 31077390
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Paired cycle-GAN-based image correction for quantitative cone-beam computed tomography.
    Harms J; Lei Y; Wang T; Zhang R; Zhou J; Tang X; Curran WJ; Liu T; Yang X
    Med Phys; 2019 Sep; 46(9):3998-4009. PubMed ID: 31206709
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dual-energy head cone-beam CT using a dual-layer flat-panel detector: Hybrid material decomposition and a feasibility study.
    Wang Z; Zhou H; Gu S; Xia Y; Liao H; Deng Y; Gao H
    Med Phys; 2023 Nov; 50(11):6762-6778. PubMed ID: 37675888
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A model-based scatter artifacts correction for cone beam CT.
    Zhao W; Vernekohl D; Zhu J; Wang L; Xing L
    Med Phys; 2016 Apr; 43(4):1736. PubMed ID: 27036571
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A correlated sampling-based Monte Carlo simulation for fast CBCT iterative scatter correction.
    Qin P; Lin G; Li X; Piao Z; Huang S; Wu W; Qi M; Ma J; Zhou L; Xu Y
    Med Phys; 2023 Mar; 50(3):1466-1480. PubMed ID: 36323626
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A generalized image quality improvement strategy of cone-beam CT using multiple spectral CT labels in Pix2pix GAN.
    Jiang Y; Zhang Y; Luo C; Yang P; Wang J; Liang X; Zhao W; Li R; Niu T
    Phys Med Biol; 2022 May; 67(11):. PubMed ID: 35487206
    [No Abstract]   [Full Text] [Related]  

  • 15. Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.
    Niu T; Zhu L
    Med Phys; 2011 Nov; 38(11):6027-38. PubMed ID: 22047367
    [TBL] [Abstract][Full Text] [Related]  

  • 16. 3D-printed large-area focused grid for scatter reduction in cone-beam CT.
    Cobos SF; Norley CJ; Nikolov HN; Holdsworth DW
    Med Phys; 2023 Jan; 50(1):240-258. PubMed ID: 36215176
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantitative cone-beam CT imaging in radiation therapy using planning CT as a prior: first patient studies.
    Niu T; Al-Basheer A; Zhu L
    Med Phys; 2012 Apr; 39(4):1991-2000. PubMed ID: 22482620
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Local filtration based scatter correction for cone-beam CT using primary modulation.
    Zhu L
    Med Phys; 2016 Nov; 43(11):6199. PubMed ID: 27806607
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Streaking artifact reduction for CBCT-based synthetic CT generation in adaptive radiotherapy.
    Gao L; Xie K; Sun J; Lin T; Sui J; Yang G; Ni X
    Med Phys; 2023 Feb; 50(2):879-893. PubMed ID: 36183234
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information.
    Lee H; Xing L; Lee R; Fahimian BP
    Med Phys; 2012 May; 39(5):2386-95. PubMed ID: 22559608
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.