BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 37657068)

  • 1. Artificial Intelligence Iterative Reconstruction in Computed Tomography Angiography: An Evaluation on Pulmonary Arteries and Aorta With Routine Dose Settings.
    Gong H; Peng L; Du X; An J; Peng R; Guo R; Ma X; Xiong S; Ma Q; Zhang G; Ma J
    J Comput Assist Tomogr; 2024 Mar-Apr 01; 48(2):244-250. PubMed ID: 37657068
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Image quality assessment of artificial intelligence iterative reconstruction for low dose aortic CTA: A feasibility study of 70 kVp and reduced contrast medium volume.
    Li W; You Y; Zhong S; Shuai T; Liao K; Yu J; Zhao J; Li Z; Lu C
    Eur J Radiol; 2022 Apr; 149():110221. PubMed ID: 35196615
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Diagnostic CT of colorectal cancer with artificial intelligence iterative reconstruction: A clinical evaluation.
    Li J; Zhu J; Zou Y; Zhang G; Zhu P; Wang N; Xie P
    Eur J Radiol; 2024 Feb; 171():111301. PubMed ID: 38237522
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ultra-low-dose CT lung screening with artificial intelligence iterative reconstruction: evaluation via automatic nodule-detection software.
    Yang L; Liu H; Han J; Xu S; Zhang G; Wang Q; Du Y; Yang F; Zhao X; Shi G
    Clin Radiol; 2023 Jul; 78(7):525-531. PubMed ID: 36948944
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Clinical Application of "Three-Low" Technique Combined with Artificial Intelligence Iterative Reconstruction Algorithm in Aortic CT Angiography].
    You YC; Li WJ; Liu HC; Zhong SH; Li ZL
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2022 Jul; 53(4):676-681. PubMed ID: 35871740
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Image quality comparison of lower extremity CTA between CT routine reconstruction algorithms and deep learning reconstruction.
    Zhang D; Mu C; Zhang X; Yan J; Xu M; Wang Y; Wang Y; Xue H; Chen Y; Jin Z
    BMC Med Imaging; 2023 Feb; 23(1):33. PubMed ID: 36800947
    [TBL] [Abstract][Full Text] [Related]  

  • 7. CT pulmonary angiography: dose reduction via a next generation iterative reconstruction algorithm.
    Sauter A; Koehler T; Brendel B; Aichele J; Neumann J; Noël PB; Rummeny EJ; Muenzel D
    Acta Radiol; 2019 Apr; 60(4):478-487. PubMed ID: 29933714
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Improvement in Image Quality and Visibility of Coronary Arteries, Stents, and Valve Structures on CT Angiography by Deep Learning Reconstruction.
    Otgonbaatar C; Ryu JK; Shin J; Woo JY; Seo JW; Shim H; Hwang DH
    Korean J Radiol; 2022 Nov; 23(11):1044-1054. PubMed ID: 36196766
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Knowledge-based iterative model reconstruction in coronary computed tomography angiography: comparison with hybrid iterative reconstruction and filtered back projection.
    Cha MJ; Seo JS; Yoo DS; Chong S
    Acta Radiol; 2018 Mar; 59(3):280-286. PubMed ID: 28648124
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improved image quality and low radiation dose with hybrid iterative reconstruction with 80 kV CT pulmonary angiography.
    Laqmani A; Regier M; Veldhoen S; Backhaus A; Wassenberg F; Sehner S; Groth M; Nagel HD; Adam G; Henes FO
    Eur J Radiol; 2014 Oct; 83(10):1962-9. PubMed ID: 25084687
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of pulmonary embolism on computed tomography: improvement using a model-based iterative reconstruction algorithm compared with filtered back projection and iterative reconstruction algorithms.
    Kligerman S; Lahiji K; Weihe E; Lin CT; Terpenning S; Jeudy J; Frazier A; Pugatch R; Galvin JR; Mittal D; Kothari K; White CS
    J Thorac Imaging; 2015 Jan; 30(1):60-8. PubMed ID: 25423129
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Image Quality of CT Angiography of Supra-Aortic Arteries : Comparison Between Advanced Modelled Iterative Reconstruction (ADMIRE), Sinogram Affirmed Iterative Reconstruction (SAFIRE) and Filtered Back Projection (FBP) in One Patients' Group.
    Örgel A; Bier G; Hennersdorf F; Richter H; Ernemann U; Hauser TK
    Clin Neuroradiol; 2020 Mar; 30(1):101-107. PubMed ID: 30397728
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential.
    Winklehner A; Karlo C; Puippe G; Schmidt B; Flohr T; Goetti R; Pfammatter T; Frauenfelder T; Alkadhi H
    Eur Radiol; 2011 Dec; 21(12):2521-6. PubMed ID: 21822785
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Image quality of ct angiography using model-based iterative reconstruction in infants with congenital heart disease: Comparison with filtered back projection and hybrid iterative reconstruction.
    Jia Q; Zhuang J; Jiang J; Li J; Huang M; Liang C
    Eur J Radiol; 2017 Jan; 86():190-197. PubMed ID: 28027746
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of contrast enhancement boost postprocessing technique in combination with different reconstruction algorithms on the image quality of abdominal CT angiography.
    Xu J; Wang S; Wang X; Wang Y; Xue H; Yan J; Xu M; Jin Z
    Eur J Radiol; 2022 Sep; 154():110388. PubMed ID: 35714492
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultra-low-dose CT reconstructed with the artificial intelligence iterative reconstruction algorithm (AIIR) in
    Hu Y; Zheng Z; Yu H; Wang J; Yang X; Shi H
    EJNMMI Phys; 2023 Jan; 10(1):1. PubMed ID: 36592256
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Raw-data-based iterative reconstruction versus filtered back projection: image quality of low-dose chest computed tomography examinations in 87 patients.
    Wang H; Tan B; Zhao B; Liang C; Xu Z
    Clin Imaging; 2013; 37(6):1024-32. PubMed ID: 23916244
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A hybrid iterative reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography.
    Oda S; Utsunomiya D; Funama Y; Yonenaga K; Namimoto T; Nakaura T; Yamashita Y
    AJR Am J Roentgenol; 2012 May; 198(5):1126-31. PubMed ID: 22528903
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Chest CT with iterative reconstruction algorithms for airway stent evaluation in patients with malignant obstructive tracheobronchial diseases.
    Li T; Zhang Y; Wang Y; Gao J; Jiang Y
    Medicine (Baltimore); 2016 Sep; 95(39):e4873. PubMed ID: 27684818
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved accuracy of pulmonary embolism computer-aided detection using iterative reconstruction compared with filtered back projection.
    Lahiji K; Kligerman S; Jeudy J; White C
    AJR Am J Roentgenol; 2014 Oct; 203(4):763-71. PubMed ID: 25247942
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.