These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
109 related articles for article (PubMed ID: 37677022)
21. Multicenter evaluation of light transmission platelet aggregation reagents: communication from the ISTH SSC Subcommittee on Platelet Physiology. Alessi MC; Coxon C; Ibrahim-Kosta M; Bacci M; Voisin S; Rivera J; Greinacher A; Raster J; Pulcinelli F; Devreese KMJ; Mullier F; McCormick AN; Frontroth JP; Pouplard C; Sachs UJ; Diaz I; Bermejo N; Camera M; Fontana P; Bauters A; Stepanian A; Cozzi MR; Sveshnikova AN; Faille D; Hollon W; Chitlur M; Casonato A; Lasne D; Lavenu-Bombled C; Fiore M; Hamidou B; Hurtaud-Roux MF; Saultier P; Goumidi L; Gresele P; Lordkipanidzé M J Thromb Haemost; 2023 Sep; 21(9):2596-2610. PubMed ID: 37331519 [TBL] [Abstract][Full Text] [Related]
22. Implementation of buffy-coat-derived pooled platelet concentrates for internal quality control of light transmission aggregometry: a proof of concept study. Prüller F; Rosskopf K; Mangge H; Mahla E; von Lewinski D; Weiss EC; Riegler A; Enko D J Thromb Haemost; 2017 Dec; 15(12):2443-2450. PubMed ID: 29028283 [TBL] [Abstract][Full Text] [Related]
23. Light transmission aggregometry using pre-coated microtiter plates and a Victor X5 plate reader. Vinholt PJ; Nybo M; Nielsen CB; Hvas AM PLoS One; 2017; 12(10):e0185675. PubMed ID: 29023589 [TBL] [Abstract][Full Text] [Related]
24. Mapping the platelet profile for functional genomic studies and demonstration of the effect size of the GP6 locus. Jones CI; Garner SF; Angenent W; Bernard A; Berzuini C; Burns P; Farndale RW; Hogwood J; Rankin A; Stephens JC; Tom BD; Walton J; Dudbridge F; Ouwehand WH; Goodall AH; J Thromb Haemost; 2007 Aug; 5(8):1756-65. PubMed ID: 17663743 [TBL] [Abstract][Full Text] [Related]
25. Agonist-Evoked Increases in Intra-Platelet Zinc Couple to Functional Responses. Ahmed NS; Lopes Pires ME; Taylor KA; Pugh N Thromb Haemost; 2019 Jan; 119(1):128-139. PubMed ID: 30597507 [TBL] [Abstract][Full Text] [Related]
26. Monomeric (glycine-proline-hydroxyproline)10 repeat sequence is a partial agonist of the platelet collagen receptor glycoprotein VI. Asselin J; Knight CG; Farndale RW; Barnes MJ; Watson SP Biochem J; 1999 Apr; 339 ( Pt 2)(Pt 2):413-8. PubMed ID: 10191274 [TBL] [Abstract][Full Text] [Related]
27. Collagen-platelet interaction: Gly-Pro-Hyp is uniquely specific for platelet Gp VI and mediates platelet activation by collagen. Knight CG; Morton LF; Onley DJ; Peachey AR; Ichinohe T; Okuma M; Farndale RW; Barnes MJ Cardiovasc Res; 1999 Feb; 41(2):450-7. PubMed ID: 10341844 [TBL] [Abstract][Full Text] [Related]
28. Inhibition of Src but not Syk causes weak reversal of GPVI-mediated platelet aggregation measured by light transmission aggregometry. Cheung HYF; Moran LA; Sickmann A; Heemskerk JWM; Garcia Á; Watson SP Platelets; 2022 Nov; 33(8):1293-1300. PubMed ID: 35535424 [TBL] [Abstract][Full Text] [Related]
29. Validation of flow cytometric analysis of platelet function in patients with a suspected platelet function defect. van Asten I; Schutgens REG; Baaij M; Zandstra J; Roest M; Pasterkamp G; Huisman A; Korporaal SJA; Urbanus RT J Thromb Haemost; 2018 Apr; 16(4):689-698. PubMed ID: 29337406 [TBL] [Abstract][Full Text] [Related]
31. Evaluation of the platelet count drop method for assessment of platelet function in comparison with "gold standard" light transmission aggregometry. Lordkipanidzé M; Pharand C; Schampaert E; Palisaitis DA; Diodati JG Thromb Res; 2009 Sep; 124(4):418-22. PubMed ID: 19250657 [TBL] [Abstract][Full Text] [Related]
32. The use of the point of care Helena ICHOR/Plateletworks and the Accumetrics Ultegra RPFA for assessment of platelet function with GPIIB-IIIa antagonists. White MM; Krishnan R; Kueter TJ; Jacoski MV; Jennings LK J Thromb Thrombolysis; 2004 Dec; 18(3):163-9. PubMed ID: 15815877 [TBL] [Abstract][Full Text] [Related]
33. Platelet activation induces metalloproteinase-dependent GP VI cleavage to down-regulate platelet reactivity to collagen. Stephens G; Yan Y; Jandrot-Perrus M; Villeval JL; Clemetson KJ; Phillips DR Blood; 2005 Jan; 105(1):186-91. PubMed ID: 15339851 [TBL] [Abstract][Full Text] [Related]
34. High on-treatment platelet reactivity by more than one agonist predicts 12-month follow-up cardiovascular death and non-fatal myocardial infarction in acute coronary syndrome patients receiving coronary stenting. Marcucci R; Gori AM; Paniccia R; Giusti B; Valente S; Giglioli C; Buonamici P; Antoniucci D; Abbate R; Gensini GF Thromb Haemost; 2010 Aug; 104(2):279-86. PubMed ID: 20508896 [TBL] [Abstract][Full Text] [Related]
35. Comparison of VASP-phosphorylation assay to light-transmission aggregometry in assessing inhibition of the platelet ADP P2Y12 receptor. Pampuch A; Cerletti C; de Gaetano G Thromb Haemost; 2006 Dec; 96(6):767-73. PubMed ID: 17139371 [TBL] [Abstract][Full Text] [Related]
36. Structural basis for the platelet-collagen interaction: the smallest motif within collagen that recognizes and activates platelet Glycoprotein VI contains two glycine-proline-hydroxyproline triplets. Smethurst PA; Onley DJ; Jarvis GE; O'Connor MN; Knight CG; Herr AB; Ouwehand WH; Farndale RW J Biol Chem; 2007 Jan; 282(2):1296-304. PubMed ID: 17085439 [TBL] [Abstract][Full Text] [Related]
37. Comparison of conventional aggregometry with VASP for monitoring P2Y12-specific platelet inhibition. Aradi D; Magyarlaki T; Tokés-Füzesi M; Rideg O; Vorobcsuk A; Komócsi A Platelets; 2010; 21(7):563-70. PubMed ID: 20642320 [TBL] [Abstract][Full Text] [Related]