134 related articles for article (PubMed ID: 37681304)
1. A Biomechanical Evaluation of Casting Technique and Cast Core Size Effect.
Sprenkle TP; Chong ACM; Shearer JD; Fisher BT; Sauer BR
J Pediatr Orthop; 2023 Nov-Dec 01; 43(10):e816-e822. PubMed ID: 37681304
[TBL] [Abstract][Full Text] [Related]
2. Cast-saw burns: evaluation of skin, cast, and blade temperatures generated during cast removal.
Shuler FD; Grisafi FN
J Bone Joint Surg Am; 2008 Dec; 90(12):2626-30. PubMed ID: 19047707
[TBL] [Abstract][Full Text] [Related]
3. What is the best material for molding casts in children?
Daines SB; Aronsson DD; Beynnon BD; Sturnick DR; Lisle JW; Naud S
J Pediatr Orthop; 2014; 34(7):743-8. PubMed ID: 24590347
[TBL] [Abstract][Full Text] [Related]
4. Skin surface pressure beneath an above-the-knee cast: plaster casts compared with fiberglass casts.
Davids JR; Frick SL; Skewes E; Blackhurst DW
J Bone Joint Surg Am; 1997 Apr; 79(4):565-9. PubMed ID: 9111402
[TBL] [Abstract][Full Text] [Related]
5. Effect of pressure applied during casting on temperatures beneath casts.
Deignan BJ; Iaquinto JM; Eskildsen SM; Woodcock CA; Owen JR; Wayne JS; Kuester VG
J Pediatr Orthop; 2011; 31(7):791-7. PubMed ID: 21926879
[TBL] [Abstract][Full Text] [Related]
6. The Effects of Splitting an Above Elbow Cast: A biomechanical study.
Vokes J; Obudzinski S; Knapp E; O'Malley S; Awad H; O'Malley N
Injury; 2020 Aug; 51(8):1759-1762. PubMed ID: 32536528
[TBL] [Abstract][Full Text] [Related]
7. Do split paediatric forearm POP casts need to be completed? A biomechanical study.
Patel N; Wilson L; Wansbrough G
Injury; 2015 Jul; 46(7):1231-7. PubMed ID: 25910820
[TBL] [Abstract][Full Text] [Related]
8. Commonly used adjuvants (liquid soap, foam sanitizer, or ultrasound gel) do not improve strength or curing time of fiberglass cast material.
Meng MRI; Elphingstone JW; Sinkler MA; Byrd BM; McGee-Lawrence ME
J Orthop Surg Res; 2019 May; 14(1):166. PubMed ID: 31146763
[TBL] [Abstract][Full Text] [Related]
9. Mechanical properties and material characteristics of orthopaedic casting material.
Mihalko WM; Beaudoin AJ; Krause WR
J Orthop Trauma; 1989; 3(1):57-63. PubMed ID: 2709205
[TBL] [Abstract][Full Text] [Related]
10. Hybrid casts: a comparison of different casting materials.
Philbin TM; Gittins ME
J Am Osteopath Assoc; 1999 Jun; 99(6):311-2. PubMed ID: 10405517
[TBL] [Abstract][Full Text] [Related]
11. Test of Strength: Figure-of-Eight versus Spiral Wrapping Technique for Fiberglass Casts.
Montgomery BK; Storaci HW; Segovia NA; Young J
Cureus; 2020 Apr; 12(4):e7843. PubMed ID: 32483494
[TBL] [Abstract][Full Text] [Related]
12. A Biomechanical Comparison of Fiberglass Casts and 3-Dimensional-Printed, Open-Latticed, Ventilated Casts.
Hoogervorst P; Knox R; Tanaka K; Working ZM; El Naga AN; Herfat S; Lee N
Hand (N Y); 2020 Nov; 15(6):842-849. PubMed ID: 30813805
[No Abstract] [Full Text] [Related]
13. Skin surface pressures under short leg casts.
Marson BM; Keenan MA
J Orthop Trauma; 1993; 7(3):275-8. PubMed ID: 8326434
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of fiberglass versus plaster of Paris for immobilization of fractures of the arm and leg.
Kowalski KL; Pitcher JD; Bickley B
Mil Med; 2002 Aug; 167(8):657-61. PubMed ID: 12188237
[TBL] [Abstract][Full Text] [Related]
15. Mechanical evaluation of a soft cast material.
Zmurko MG; Belkoff SM; Herzenberg JE
Orthopedics; 1997 Aug; 20(8):693-8. PubMed ID: 9263288
[TBL] [Abstract][Full Text] [Related]
16. Three-dimensional analysis of the gap space under forearm casts.
Wirtz R; Pianigiani S; Innocenti B; Schuind F
Chin J Traumatol; 2022 Mar; 25(2):77-82. PubMed ID: 34154866
[TBL] [Abstract][Full Text] [Related]
17. A comparison of the mechanical properties of fiberglass cast materials and their clinical relevance.
Berman AT; Parks BG
J Orthop Trauma; 1990; 4(1):85-92. PubMed ID: 2313436
[TBL] [Abstract][Full Text] [Related]
18. Treatment of clubfoot with the Ponseti method: a comparison of casting materials.
Pittner DE; Klingele KE; Beebe AC
J Pediatr Orthop; 2008 Mar; 28(2):250-3. PubMed ID: 18388724
[TBL] [Abstract][Full Text] [Related]
19. Conventional vs 3-Dimensional Printed Cast Wear Comfort.
Graham J; Wang M; Frizzell K; Watkins C; Beredjiklian P; Rivlin M
Hand (N Y); 2020 May; 15(3):388-392. PubMed ID: 30146902
[No Abstract] [Full Text] [Related]
20. Cast changes: synthetic versus plaster.
Adkins LM
Pediatr Nurs; 1997; 23(4):422, 425-7. PubMed ID: 9282058
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]