BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 37684357)

  • 1. Nonvascularized fibular graft with locking screw fixation for metaphyseal bone loss of distal femur: biomechanical assessment validated by a clinical case series.
    Jitprapaikulsarn S; Chantarapanich N; Gromprasit A; Mahaisavariya C; Sukha K; Rungsakaolert P
    Eur J Orthop Surg Traumatol; 2024 Jan; 34(1):659-671. PubMed ID: 37684357
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dual plating for fixation failure of the distal femur: Finite element analysis and a clinical series.
    Jitprapaikulsarn S; Chantarapanich N; Gromprasit A; Mahaisavariya C; Sukha K; Chiawchan S
    Med Eng Phys; 2023 Jan; 111():103926. PubMed ID: 36792233
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Single lag screw and reverse distal femur locking compression plate for concurrent cervicotrochanteric and shaft fractures of the femur: biomechanical study validated with a clinical series.
    Jitprapaikulsarn S; Chantarapanich N; Gromprasit A; Mahaisavariya C; Patamamongkonchai C
    Eur J Orthop Surg Traumatol; 2021 Aug; 31(6):1179-1192. PubMed ID: 33417049
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Filling Open Screw Holes in the Area of Metaphyseal Comminution Does Not Affect Fatigue Life of the Synthes Variable Angle Distal Femoral Locking Plate in the AO/OTA 33-A3 Fracture Model.
    Grau L; Collon K; Alhandi A; Kaimrajh D; Varon M; Latta L; Vilella F
    Surg Technol Int; 2018 Jun; 32():293-297. PubMed ID: 29791694
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biphasic plating improves the mechanical performance of locked plating for distal femur fractures.
    Epari DR; Gurung R; Hofmann-Fliri L; Schwyn R; Schuetz M; Windolf M
    J Biomech; 2021 Jan; 115():110192. PubMed ID: 33385868
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reverse distal femoral locking compression plate (DF-LCP), does it fit and how to fit on Asian's proximal femurs? A cadaveric study.
    Apivatthakakul V; Apivatthakakul T
    Eur J Orthop Surg Traumatol; 2022 Jul; 32(5):991-1000. PubMed ID: 34236513
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Semi-rigid screws provide an auxiliary option to plate working length to control interfragmentary movement in locking plate fixation at the distal femur.
    Heyland M; Duda GN; Haas NP; Trepczynski A; Döbele S; Höntzsch D; Schaser KD; Märdian S
    Injury; 2015 Oct; 46 Suppl 4():S24-32. PubMed ID: 26542863
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mismatch of anatomically pre-shaped locking plate on Asian femurs could lead to malalignment in the minimally invasive plating of distal femoral fractures: a cadaveric study.
    Hwang JH; Oh JK; Oh CW; Yoon YC; Choi HW
    Arch Orthop Trauma Surg; 2012 Jan; 132(1):51-6. PubMed ID: 21833785
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Modified pin and plate fixation for low intercondylar fractures of the humerus: biomechanical study corroborated with a case series.
    Jitprapaikulsarn S; Chantarapanich N; Gromprasit A; Mahaisavariya C; Patamamongkonchai C
    Musculoskelet Surg; 2023 Jun; 107(2):207-221. PubMed ID: 35362865
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Working length and proximal screw constructs in plate osteosynthesis of distal femur fractures.
    Harvin WH; Oladeji LO; Della Rocca GJ; Murtha YM; Volgas DA; Stannard JP; Crist BD
    Injury; 2017 Nov; 48(11):2597-2601. PubMed ID: 28889934
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur Plate.
    Tank JC; Schneider PS; Davis E; Galpin M; Prasarn ML; Choo AM; Munz JW; Achor TS; Kellam JF; Gary JL
    J Orthop Trauma; 2016 Jan; 30(1):e7-e11. PubMed ID: 26849390
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simulation-based particle swarm optimization and mechanical validation of screw position and number for the fixation stability of a femoral locking compression plate.
    Lee CH; Shih KS; Hsu CC; Cho T
    Med Eng Phys; 2014 Jan; 36(1):57-64. PubMed ID: 24090880
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.
    Kandemir U; Augat P; Konowalczyk S; Wipf F; von Oldenburg G; Schmidt U
    J Orthop Trauma; 2017 Aug; 31(8):e241-e246. PubMed ID: 28394844
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reversed distal femoral locking plate for failed proximal femoral nail with non-union of proximal femoral fractures.
    Vaishya R; Agarwal AK; Gupta N; Vijay V
    Int Orthop; 2016 Aug; 40(8):1709-1715. PubMed ID: 26450842
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant: the effect of cable-screw position.
    Dubov A; Kim SY; Shah S; Schemitsch EH; Zdero R; Bougherara H
    Proc Inst Mech Eng H; 2011 Sep; 225(9):857-65. PubMed ID: 22070023
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Do Transcortical Screws in a Locking Plate Construct Improve the Stiffness in the Fixation of Vancouver B1 Periprosthetic Femur Fractures? A Biomechanical Analysis of 2 Different Plating Constructs.
    Lochab J; Carrothers A; Wong E; McLachlin S; Aldebeyan W; Jenkinson R; Whyne C; Nousiainen MT
    J Orthop Trauma; 2017 Jan; 31(1):15-20. PubMed ID: 28002219
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [A new exploration and consideration of Type A fracture of distal femur based on finite element biomechanical analysis].
    Xu D; Sun RJ; Wang TY; Zhao XQ; Bi ZG; Geng S
    Zhonghua Wai Ke Za Zhi; 2019 Nov; 57(11):812-817. PubMed ID: 31694128
    [No Abstract]   [Full Text] [Related]  

  • 18. What Is the Likelihood of Union After Coronal Limb Realignment Using Revision Osteosynthesis and Concurrent TKA in Patients with Advanced Arthritis and Loss of Fixation After Distal Metaphyseal Femur Fractures?
    Gavaskar AS; Srinivasan P; Raj RV; Jayakumar B; Pattabiraman K
    Clin Orthop Relat Res; 2021 Jun; 479(6):1252-1261. PubMed ID: 33512959
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?
    Stoffel K; Dieter U; Stachowiak G; Gächter A; Kuster MS
    Injury; 2003 Nov; 34 Suppl 2():B11-9. PubMed ID: 14580982
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Osteosynthesis for periprosthetic supracondylar fracture above a total knee arthroplasty using a locking compression plate].
    Krbec M; Motycka J; Lunácek L; Dousa P
    Acta Chir Orthop Traumatol Cech; 2009 Dec; 76(6):473-8. PubMed ID: 20067694
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.