These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
184 related articles for article (PubMed ID: 37696040)
1. Evaluation of intensity-modulated electron FLASH radiotherapy in a clinical setting using veterinary cases. Konradsson E; Szecsenyi RE; Adrian G; Coskun M; Børresen B; Arendt ML; Erhart K; Bäck SÅ; Petersson K; Ceberg C Med Phys; 2023 Oct; 50(10):6569-6579. PubMed ID: 37696040 [TBL] [Abstract][Full Text] [Related]
2. Simultaneous beam geometry and intensity map optimization in intensity-modulated radiation therapy. Lee EK; Fox T; Crocker I Int J Radiat Oncol Biol Phys; 2006 Jan; 64(1):301-20. PubMed ID: 16289912 [TBL] [Abstract][Full Text] [Related]
3. 3D-conformal very-high energy electron therapy as candidate modality for FLASH-RT: A treatment planning study for glioblastoma and lung cancer. Böhlen TT; Germond JF; Traneus E; Vallet V; Desorgher L; Ozsahin EM; Bochud F; Bourhis J; Moeckli R Med Phys; 2023 Sep; 50(9):5745-5756. PubMed ID: 37427669 [TBL] [Abstract][Full Text] [Related]
4. Dosimetric validation of intensity-modulated bolus electron conformal therapy planning and delivery using an anthropomorphic cylindrical head phantom. McGuffey AS; Pitcher GM; Erhart KJ; Hogstrom KR J Appl Clin Med Phys; 2024 Jul; 25(7):e14347. PubMed ID: 38576174 [TBL] [Abstract][Full Text] [Related]
5. Forward treatment planning for modulated electron radiotherapy (MERT) employing Monte Carlo methods. Henzen D; Manser P; Frei D; Volken W; Neuenschwander H; Born EJ; Lössl K; Aebersold DM; Stampanoni MF; Fix MK Med Phys; 2014 Mar; 41(3):031712. PubMed ID: 24593716 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of a mixed beam therapy for postmastectomy breast cancer patients: Bolus electron conformal therapy combined with intensity modulated photon radiotherapy and volumetric modulated photon arc therapy. Zhang R; Heins D; Sanders M; Guo B; Hogstrom K Med Phys; 2018 Jul; 45(7):2912-2924. PubMed ID: 29749075 [TBL] [Abstract][Full Text] [Related]
7. Optimal selection of optimization bolus thickness in planning of VMAT breast radiotherapy treatments. Rossi M; Boman E; Kapanen M Med Dosim; 2019 Autumn; 44(3):266-273. PubMed ID: 30389413 [TBL] [Abstract][Full Text] [Related]
8. Delivery confirmation of bolus electron conformal therapy combined with intensity modulated x-ray therapy. Kavanaugh JA; Hogstrom KR; Chu C; Carver RA; Fontenot JP; Henkelmann G Med Phys; 2013 Feb; 40(2):021724. PubMed ID: 23387747 [TBL] [Abstract][Full Text] [Related]
9. Treatment planning consideration for very high-energy electron FLASH radiotherapy. Zhang G; Zhang Z; Gao W; Quan H Phys Med; 2023 Mar; 107():102539. PubMed ID: 36804694 [TBL] [Abstract][Full Text] [Related]
10. Use of single-energy proton pencil beam scanning Bragg peak for intensity-modulated proton therapy FLASH treatment planning in liver-hypofractionated radiation therapy. Wei S; Lin H; Shi C; Xiong W; Chen CC; Huang S; Press RH; Hasan S; Chhabra AM; Choi JI; Simone CB; Kang M Med Phys; 2022 Oct; 49(10):6560-6574. PubMed ID: 35929404 [TBL] [Abstract][Full Text] [Related]
11. Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy. Pokhrel D; Sood S; McClinton C; Shen X; Lominska C; Saleh H; Badkul R; Jiang H; Mitchell M; Wang F Med Dosim; 2016 Winter; 41(4):315-322. PubMed ID: 27692518 [TBL] [Abstract][Full Text] [Related]
12. Preliminary comparison of helical tomotherapy and mixed beams of unmodulated electrons and intensity modulated radiation therapy for treating superficial cancers of the parotid gland and nasal cavity. Blasi O; Fontenot JD; Fields RS; Gibbons JP; Hogstrom KR Radiat Oncol; 2011 Dec; 6():178. PubMed ID: 22204477 [TBL] [Abstract][Full Text] [Related]
13. Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans. Bazalova-Carter M; Qu B; Palma B; Hårdemark B; Hynning E; Jensen C; Maxim PG; Loo BW Med Phys; 2015 May; 42(5):2615-25. PubMed ID: 25979053 [TBL] [Abstract][Full Text] [Related]
14. Design and production of 3D printed bolus for electron radiation therapy. Su S; Moran K; Robar JL J Appl Clin Med Phys; 2014 Jul; 15(4):4831. PubMed ID: 25207410 [TBL] [Abstract][Full Text] [Related]
15. Planning and delivery of intensity modulated bolus electron conformal therapy. Hilliard EN; Carver RL; Chambers EL; Kavanaugh JA; Erhart KJ; McGuffey AS; Hogstrom KR J Appl Clin Med Phys; 2021 Oct; 22(10):8-21. PubMed ID: 34558774 [TBL] [Abstract][Full Text] [Related]
16. Dosimetric benefits of 3D-printed modulated electron bolus following lumpectomy and whole-breast radiotherapy for left breast cancer. Lee VWY; Liu ACH; Cheng KW; Chiang CL; Lee VH Med Dosim; 2023 Spring; 48(1):37-43. PubMed ID: 36336582 [TBL] [Abstract][Full Text] [Related]
17. A hybrid electron and photon IMRT planning technique that lowers normal tissue integral patient dose using standard hardware. Rosca F Med Phys; 2012 Jun; 39(6):2964-71. PubMed ID: 22755681 [TBL] [Abstract][Full Text] [Related]
18. Development and evaluation of multiple isocentric volumetric modulated arc therapy technique for craniospinal axis radiotherapy planning. Lee YK; Brooks CJ; Bedford JL; Warrington AP; Saran FH Int J Radiat Oncol Biol Phys; 2012 Feb; 82(2):1006-12. PubMed ID: 21345612 [TBL] [Abstract][Full Text] [Related]
19. Inverse planning of energy-modulated electron beams in radiotherapy. Gentry JR; Steeves R; Paliwal BA Med Dosim; 2006; 31(4):259-68. PubMed ID: 17134665 [TBL] [Abstract][Full Text] [Related]
20. Dosimetric verification of surface and superficial doses for head and neck IMRT with different PTV shrinkage margins. Shiau AC; Lai PL; Liang JA; Shueng PW; Chen WL; Kuan WP Med Phys; 2011 Mar; 38(3):1435-43. PubMed ID: 21520855 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]