These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 37710827)

  • 21. Tunable-diode-laser spectroscopy of C(2)H(2) using a 3.03 microm GaInAsSb/AlGaInAsSb distributed-feedback laser.
    Kluczynski P; Lundqvist S; Belahsene S; Rouillard Y
    Opt Lett; 2009 Dec; 34(24):3767-9. PubMed ID: 20016607
    [TBL] [Abstract][Full Text] [Related]  

  • 22. THz QCL-based cryogen-free spectrometer for in situ trace gas sensing.
    Consolino L; Bartalini S; Beere HE; Ritchie DA; Vitiello MS; De Natale P
    Sensors (Basel); 2013 Mar; 13(3):3331-40. PubMed ID: 23478601
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Mid-Infrared Trace CH4 Detector Based on TDLAS-WMS].
    Qu SM; Wang M; Li N
    Guang Pu Xue Yu Guang Pu Fen Xi; 2016 Oct; 36(10):3174-8. PubMed ID: 30222265
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Breath analysis with broadly tunable quantum cascade lasers.
    Wörle K; Seichter F; Wilk A; Armacost C; Day T; Godejohann M; Wachter U; Vogt J; Radermacher P; Mizaikoff B
    Anal Chem; 2013 Mar; 85(5):2697-702. PubMed ID: 23320383
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Broadband spectroscopy with external cavity quantum cascade lasers beyond conventional absorption measurements.
    Lambrecht A; Pfeifer M; Konz W; Herbst J; Axtmann F
    Analyst; 2014 May; 139(9):2070-8. PubMed ID: 24367797
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [A trace gas sensor using mid-infrared quantum cascaded laser at 4.8 microm to detect carbon monoxide].
    Chen C; Wang B; Li CG; Li J; Wang YD
    Guang Pu Xue Yu Guang Pu Fen Xi; 2014 Mar; 34(3):838-42. PubMed ID: 25208424
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Quantum cascade lasers: from tool to product.
    Razeghi M; Lu QY; Bandyopadhyay N; Zhou W; Heydari D; Bai Y; Slivken S
    Opt Express; 2015 Apr; 23(7):8462-75. PubMed ID: 25968685
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [A trace methane gas sensor using mid-infrared quantum cascaded laser at 7.5 microm].
    Chen C; Dang JM; Huang JQ; Yang Y; Wang YD
    Guang Pu Xue Yu Guang Pu Fen Xi; 2012 Nov; 32(11):3146-50. PubMed ID: 23387197
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Frequency tuning behaviour of terahertz quantum cascade lasers revealed by a laser beating scheme.
    Guan W; Liao X; Li Z; Wan W; Zhou K; Zhao Y; Wang C; Ma X; Wang S; Cao JC; Xu D; Zhang J; Chi N; Li H
    Opt Express; 2021 Jul; 29(14):21269-21279. PubMed ID: 34265917
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Ppb-level detection of nitric oxide using an external cavity quantum cascade laser based QEPAS sensor.
    Dong L; Spagnolo V; Lewicki R; Tittel FK
    Opt Express; 2011 Nov; 19(24):24037-45. PubMed ID: 22109428
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Simultaneous atmospheric nitrous oxide, methane and water vapor detection with a single continuous wave quantum cascade laser.
    Cao Y; Sanchez NP; Jiang W; Griffin RJ; Xie F; Hughes LC; Zah CE; Tittel FK
    Opt Express; 2015 Feb; 23(3):2121-32. PubMed ID: 25836083
    [TBL] [Abstract][Full Text] [Related]  

  • 32. High frequency modulation and (quasi) single-sideband emission of mid-infrared ring and ridge quantum cascade lasers.
    Hinkov B; Hayden J; Szedlak R; Martin-Mateos P; Jerez B; Acedo P; Strasser G; Lendl B
    Opt Express; 2019 May; 27(10):14716-14724. PubMed ID: 31163916
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Ultra-highly sensitive dual gases detection based on photoacoustic spectroscopy by exploiting a long-wave, high-power, wide-tunable, single-longitudinal-mode solid-state laser.
    Qiao S; He Y; Sun H; Patimisco P; Sampaolo A; Spagnolo V; Ma Y
    Light Sci Appl; 2024 May; 13(1):100. PubMed ID: 38693126
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Sub-ppb detection of benzene using cantilever-enhanced photoacoustic spectroscopy with a long-wavelength infrared quantum cascade laser.
    Karhu J; Philip H; Baranov A; Teissier R; Hieta T
    Opt Lett; 2020 Nov; 45(21):5962-5965. PubMed ID: 33137041
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Ppt level carbon monoxide detection based on light-induced thermoelastic spectroscopy exploring custom quartz tuning forks and a mid-infrared QCL.
    Qiao S; Ma Y; He Y; Patimisco P; Sampaolo A; Spagnolo V
    Opt Express; 2021 Aug; 29(16):25100-25108. PubMed ID: 34614848
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Resonant absorption induced fast melting studied with mid-IR QCLs.
    Lu J; Lv Y; Ji Y; Tang X; Qi Z; Li L
    Rev Sci Instrum; 2017 Feb; 88(2):023108. PubMed ID: 28249478
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Theoretical and Experimental Study of Heterodyne Phase-Sensitive Dispersion Spectroscopy with an Injection-Current-Modulated Quantum Cascade Laser.
    Wang Z; Cheong KP; Li M; Wang Q; Ren W
    Sensors (Basel); 2020 Oct; 20(21):. PubMed ID: 33138309
    [TBL] [Abstract][Full Text] [Related]  

  • 38. External cavity tunable quantum cascade lasers and their applications to trace gas monitoring.
    Rao GN; Karpf A
    Appl Opt; 2011 Feb; 50(4):A100-15. PubMed ID: 21283214
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Real-time trace gas sensing of fluorocarbons using a swept-wavelength external cavity quantum cascade laser.
    Phillips MC; Taubman MS; Bernacki BE; Cannon BD; Stahl RD; Schiffern JT; Myers TL
    Analyst; 2014 May; 139(9):2047-56. PubMed ID: 24384671
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Sensitive Spectroscopy of Acetone Using a Widely Tunable External-Cavity Quantum Cascade Laser.
    Nadeem F; Mandon J; Khodabakhsh A; Cristescu SM; Harren FJM
    Sensors (Basel); 2018 Jun; 18(7):. PubMed ID: 29954082
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.