These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 3771601)

  • 21. [A spinal cord injury caused by a migrating Kirschner wire following osteosynthesis of the clavicle: a case review].
    Pribán V; Toufar P
    Rozhl Chir; 2005 Jul; 84(7):373-5. PubMed ID: 16164089
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparing Mersilene* tape and stainless steel wire as sublaminar spinal fixation in the Chagma baboon (Papio ursinus).
    Grobler LJ; Gaines RW; Kempff PG
    Iowa Orthop J; 1997; 17():20-31. PubMed ID: 9234971
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Fracture analysis of retrieved orthopedic wires.
    Baswell IL; Sander T; Allen B; Bechtol CO
    J Biomed Mater Res; 1986 Sep; 20(7):887-94. PubMed ID: 3760005
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [What is the value of Goetze's wire cerclage in treating torsion fractures of the lower leg?].
    Rütt J; Beck E
    Unfallchirurg; 1985 Jul; 88(7):308-14. PubMed ID: 4048958
    [No Abstract]   [Full Text] [Related]  

  • 25. Aspiration of an intermaxillary fixation wire fragment.
    Nishioka GJ; Timmis DP; Triplett RG
    Anesth Prog; 1987; 34(1):14-6. PubMed ID: 3472473
    [No Abstract]   [Full Text] [Related]  

  • 26. Inability to extubate because of Kirshner wire transfixation of the endotracheal tube.
    Fukayama H; Nishibori M; Ito H; Kubota Y
    Anesth Prog; 1987; 34(2):61-2. PubMed ID: 3474912
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Complications of tension-band wiring of olecranon fractures.
    Macko D; Szabo RM
    J Bone Joint Surg Am; 1985 Dec; 67(9):1396-401. PubMed ID: 3908460
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Segmental spinal instrumentation with sublaminar wires. A critical appraisal.
    Herndon WA; Sullivan JA; Yngve DA; Gross RH; Dreher G
    J Bone Joint Surg Am; 1987 Jul; 69(6):851-9. PubMed ID: 3597498
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Cervical transdural intramedullary migration of a sublaminar wire. A complication of cervical fixation.
    Fraser AB; Sen C; Casden AM; Catalano PJ; Post KD
    Spine (Phila Pa 1976); 1994 Feb; 19(4):456-9. PubMed ID: 8178236
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Does sublaminar wiring produce spinal stenosis?
    Nixon JE
    J Bone Joint Surg Br; 1989 Jan; 71(1):92-3. PubMed ID: 2915015
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Toe fusion using Kirschner wire. A study of the postoperative infection rate and related problems.
    Reece AT; Stone MH; Young AB
    J R Coll Surg Edinb; 1987 Jun; 32(3):158-9. PubMed ID: 3656240
    [No Abstract]   [Full Text] [Related]  

  • 32. [Wire instead of cable!].
    Simon S
    Z Orthop Unfall; 2013 Aug; 151(4):332. PubMed ID: 24137693
    [No Abstract]   [Full Text] [Related]  

  • 33. Cardiac perforation after Kirschner wire migration.
    Tubbax H; Hendzel P; Sergeant P
    Acta Chir Belg; 1989; 89(6):309-11. PubMed ID: 2692365
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Biomechanical study of KMC transspinous process wiring technique with Luque segmental spinal instrumentation.
    Lin SY; Wu HJ; Law CL; Tyan IJ
    Gaoxiong Yi Xue Ke Xue Za Zhi; 1989 Aug; 5(8):459-64. PubMed ID: 2593213
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Studies of an L-rod sublaminar wire spinal fusion.
    Renshaw TS; Solga PM; Drennan JC; Donskoy E
    J Pediatr Orthop; 1991; 11(2):226-9. PubMed ID: 2010526
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Segmental rod wiring of the spinous process].
    Winkelmann W
    Z Orthop Ihre Grenzgeb; 1987; 125(2):143-8. PubMed ID: 3617886
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Preoperative sonographic localization of a migrated transosseous stabilizing wire in the hand.
    Fornage BD
    J Ultrasound Med; 1987 Aug; 6(8):471-3. PubMed ID: 3305984
    [No Abstract]   [Full Text] [Related]  

  • 38. Cobalt chromium sublaminar wires for spinal deformity surgery.
    Cluck MW; Skaggs DL
    Spine (Phila Pa 1976); 2006 Sep; 31(19):2209-12. PubMed ID: 16946655
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Stability of different wiring techniques in segmental spinal instrumentation. An experimental study.
    Heller KD; Prescher A; Schneider T; Block FR; Forst R
    Arch Orthop Trauma Surg; 1998; 117(1-2):96-9. PubMed ID: 9457349
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Complications of stable flexible wiring in the treatment of femoral fractures in children].
    Lascombes P; Prevot J; Poncelet T; Ligier JN; Blanquart D
    Rev Chir Orthop Reparatrice Appar Mot; 1988; 74 Suppl 2():293-6. PubMed ID: 3148170
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.