BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 37731203)

  • 1. A scintillation dosimeter with real-time positional tracking information for in vivo dosimetry error detection in HDR brachytherapy.
    Tho D; Lavallée MC; Beaulieu L
    J Appl Clin Med Phys; 2023 Dec; 24(12):e14150. PubMed ID: 37731203
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy.
    Linares Rosales HM; Duguay-Drouin P; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2019 May; 46(5):2412-2421. PubMed ID: 30891803
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dosimetric performance of a multipoint plastic scintillator dosimeter as a tool for real-time source tracking in high dose rate
    Linares Rosales HM; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2020 Sep; 47(9):4477-4490. PubMed ID: 32443175
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Technical Note: Identification of an optimal electromagnetic sensor for in vivo electromagnetic-tracked scintillation dosimeter for HDR brachytherapy.
    Tho D; Beaulieu L
    Med Phys; 2019 May; 46(5):2031-2036. PubMed ID: 30919450
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 3D source tracking and error detection in HDR using two independent scintillator dosimetry systems.
    Linares Rosales HM; Johansen JG; Kertzscher G; Tanderup K; Beaulieu L; Beddar S
    Med Phys; 2021 May; 48(5):2095-2107. PubMed ID: 33222208
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Six-probe scintillator dosimeter for treatment verification in HDR-brachytherapy.
    Gonod M; Suarez MA; Avila CC; Karakhanyan V; Eustache C; Laskri S; Crouzilles J; Vinchant JF; Aubignac L; Grosjean T
    Med Phys; 2023 Nov; 50(11):7192-7202. PubMed ID: 37738612
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A high-Z inorganic scintillator-based detector for time-resolved in vivo dosimetry during brachytherapy.
    Jørgensen EB; Johansen JG; Overgaard J; Piché-Meunier D; Tho D; Rosales HML; Tanderup K; Beaulieu L; Kertzscher G; Beddar S
    Med Phys; 2021 Nov; 48(11):7382-7398. PubMed ID: 34586641
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High resolution small-scale inorganic scintillator detector: HDR brachytherapy application.
    Debnath SBC; Ferre M; Tonneau D; Fauquet C; Tallet A; Goncalves A; Darreon J
    Med Phys; 2021 Apr; 48(4):1485-1496. PubMed ID: 33476399
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo characterization of high atomic number inorganic scintillators for in vivo dosimetry in
    Kaveckyte V; Jørgensen EB; Kertzscher G; Johansen JG; Carlsson Tedgren Å
    Med Phys; 2022 Jul; 49(7):4715-4730. PubMed ID: 35443079
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Use of water-equivalent plastic scintillator for intravascular brachytherapy dosimetry.
    Geso M; Robinson N; Schumer W; Williams K
    Australas Phys Eng Sci Med; 2004 Mar; 27(1):5-10. PubMed ID: 15156701
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of an enhanced afterloader with electromagnetic tracking capabilities for channel reconstruction and error detection.
    Tho D; Lavallée MC; Beaulieu L
    Med Phys; 2021 Aug; 48(8):4402-4410. PubMed ID: 33938002
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Inorganic scintillation detectors for
    Kertzscher G; Beddar S
    Phys Med Biol; 2019 Nov; 64(22):225018. PubMed ID: 31491777
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A plastic scintillation dosimeter for high dose rate brachytherapy.
    Lambert J; McKenzie DR; Law S; Elsey J; Suchowerska N
    Phys Med Biol; 2006 Nov; 51(21):5505-16. PubMed ID: 17047266
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Adaptive error detection for HDR/PDR brachytherapy: guidance for decision making during real-time in vivo point dosimetry.
    Kertzscher G; Andersen CE; Tanderup K
    Med Phys; 2014 May; 41(5):052102. PubMed ID: 24784391
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Positional and angular tracking of HDR
    Aldelaijan S; Devic S; Bekerat H; Papaconstadopoulos P; Schneider J; Seuntjens J; Cormack RA; Buzurovic IM
    Med Phys; 2020 Dec; 47(12):6122-6139. PubMed ID: 33064876
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy.
    Therriault-Proulx F; Briere TM; Mourtada F; Aubin S; Beddar S; Beaulieu L
    Med Phys; 2011 May; 38(5):2542-51. PubMed ID: 21776789
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Inorganic scintillation detectors based on Eu-activated phosphors for
    Kertzscher G; Beddar S
    Phys Med Biol; 2017 Jun; 62(12):5046-5075. PubMed ID: 28475494
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Monte Carlo dosimetric characterization of a new high dose rate
    Famulari G; Linares Rosales HM; Dupere J; Medich DC; Beaulieu L; Enger SA
    Med Phys; 2020 Sep; 47(9):4563-4573. PubMed ID: 32686145
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The angular dependence and effective point of measurement of a cylindrical scintillation dosimeter with and without a radio-opaque marker for brachytherapy.
    Cartwright LE; Lambert J; McKenzie DR; Suchowerska N
    Phys Med Biol; 2009 Apr; 54(7):2217-27. PubMed ID: 19293468
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Time-resolved in vivo dosimetry for source tracking in brachytherapy.
    Johansen JG; Rylander S; Buus S; Bentzen L; Hokland SB; Søndergaard CS; With AKM; Kertzscher G; Tanderup K
    Brachytherapy; 2018; 17(1):122-132. PubMed ID: 28943129
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.