BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 37734763)

  • 1. Evaluation of the Humidification Performances of New Generation of Heated Wire Humidifiers.
    Lellouche F; Rousseau E; Bouchard PA
    Respir Care; 2024 Mar; 69(4):430-437. PubMed ID: 37734763
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monitoring of Heated Wire Humidifier Hygrometric Performances With Heater Plate Temperature.
    Lellouche F; Simard S; Bouchard PA
    Respir Care; 2022 Sep; 67(9):1147-1153. PubMed ID: 35672136
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of ambient and ventilator output temperatures on performance of heated-wire humidifiers.
    Lellouche F; Taillé S; Maggiore SM; Qader S; L'her E; Deye N; Brochard L
    Am J Respir Crit Care Med; 2004 Nov; 170(10):1073-9. PubMed ID: 15271695
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers.
    Lellouche F; Qader S; Taillé S; Lyazidi A; Brochard L
    Respir Care; 2014 May; 59(5):637-43. PubMed ID: 24106325
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance of heated wire humidifiers: an in vitro study.
    Pelosi P; Chiumello D; Severgnini P; De Grandis CE; Landi L; Chierichetti LM; Frigerio A; Munaro M; Park G; Chiaranda M
    J Crit Care; 2007 Sep; 22(3):258-64. PubMed ID: 17869979
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of Airway Humidification Strategy in Mechanically Ventilated COVID-19 Patients.
    Lavoie-Bérard CA; Lefebvre JC; Bouchard PA; Simon M; Lellouche F
    Respir Care; 2022 Feb; 67(2):157-166. PubMed ID: 34670857
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Humidification in Very-High-Flow Nasal-Cannula Therapy in an Adult Lung Model.
    Chikata Y; Morinishi K; Nishimura M
    Respir Care; 2019 Jul; 64(7):809-817. PubMed ID: 30837330
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Y-piece temperature and humidification during mechanical ventilation.
    Solomita M; Daroowalla F; Leblanc DS; Smaldone GC
    Respir Care; 2009 Apr; 54(4):480-6. PubMed ID: 19327183
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance of heated humidifiers with a heated wire according to ventilatory settings.
    Nishida T; Nishimura M; Fujino Y; Mashimo T
    J Aerosol Med; 2001; 14(1):43-51. PubMed ID: 11495484
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Inspired gas humidity during mechanical ventilation: effects of humidification chamber, airway temperature probe position and environmental conditions.
    Todd DA; Boyd J; Lloyd J; John E
    J Paediatr Child Health; 2001 Oct; 37(5):489-94. PubMed ID: 11885715
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of leaks and ventilation parameters on the efficacy of humidifiers during home ventilation for tracheostomized patients: a bench study.
    Haziot N; Ibrahim M; Zhu K; Thevenin CP; Hardy S; Gonzalez-Bermejo J
    BMC Pulm Med; 2019 Feb; 19(1):43. PubMed ID: 30777036
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vivo efficacy of heated and non-heated humidifiers during nasal continuous positive airway pressure (nCPAP)-therapy for obstructive sleep apnoea.
    Wiest GH; Fuchs FS; Brueckl WM; Nusko G; Harsch IA; Hahn EG; Ficker JH
    Respir Med; 2000 Apr; 94(4):364-8. PubMed ID: 10845435
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance of Invasive Mode in Different Heated Humidification Systems With High-Flow Nasal Cannula.
    Plotnikow GA; Villalba DS; Calvo EP; Quiroga C; Navarro E
    Respir Care; 2022 Jul; ():. PubMed ID: 35882470
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Humidification Performance of Passive and Active Humidification Devices Within a Spontaneously Breathing Tracheostomized Cohort.
    Nakanishi N; Oto J; Itagaki T; Nakataki E; Onodera M; Nishimura M
    Respir Care; 2019 Feb; 64(2):130-135. PubMed ID: 30254040
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Compensating for the effect of inlet gas temperature on heated humidifier performance.
    Carter BG; Kemp T; Mynard J; Hochmann M; Osborne A
    Anaesth Intensive Care; 2003 Feb; 31(1):54-7. PubMed ID: 12635396
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Heated Humidifiers for Noninvasive Respiratory Support and the Risk of Burns in Neonates: A Bench Evaluation.
    Fau S; Baud O; Rimensberger P
    Respir Care; 2021 Sep; 66(9):1398-1405. PubMed ID: 34074742
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A novel control strategy to improve the performances of heated wire humidifiers in artificial neonatal ventilation.
    Schena E; Saccomandi P; Ramandi C; Silvestri S
    Physiol Meas; 2012 Jul; 33(7):1199-211. PubMed ID: 22735267
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill.
    Ricard JD; Markowicz P; Djedaini K; Mier L; Coste F; Dreyfuss D
    Chest; 1999 Jun; 115(6):1646-52. PubMed ID: 10378563
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Active humidification with Boussignac CPAP: in vitro study of a new method.
    Alonso-Iñigo JM; Almela A; Albert A; Carratalá JM; Fas MJ
    Respir Care; 2013 Apr; 58(4):647-54. PubMed ID: 22906896
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of Normothermic Default Humidifier Settings Causes Excessive Humidification of Respiratory Gases During Therapeutic Hypothermia.
    Tanaka S; Iwata S; Kinoshita M; Tsuda K; Sakai S; Saikusa M; Shindo R; Harada E; Okada J; Hisano T; Kanda H; Maeno Y; Araki Y; Ushijima K; Sakamoto T; Yamashita Y; Iwata O
    Ther Hypothermia Temp Manag; 2016 Dec; 6(4):180-188. PubMed ID: 27167667
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.