These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 37736092)

  • 1. An unpredictable complication of femoral reaming: When the reamer gets stuck.
    Jlidi M; Bouaicha W; Daas S
    Trauma Case Rep; 2023 Dec; 48():100909. PubMed ID: 37736092
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Unusual Occurrence of Incarceration and Breakage of the Coiled Shaft of the Intramedullary Reamer during Closed Intramedullary Nailing of Tibia.
    Londhe S; Antao NA; Toor R
    J Orthop Case Rep; 2021 Dec; 11(12):88-91. PubMed ID: 35415145
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Uncoiling of reamer during intramedullary nailing for fracture shaft of femur.
    Meena S; Trikha V; Singh V; Mittal S; Kishanpuria TS
    J Nat Sci Biol Med; 2013 Jul; 4(2):481-4. PubMed ID: 24082759
    [TBL] [Abstract][Full Text] [Related]  

  • 4. "Push-past" reaming as a reduction aid with intramedullary nailing of metadiaphyseal and diaphyseal femoral shaft fractures.
    Gary JL; Munz JW; Burgess AR
    Orthopedics; 2014 Jun; 37(6):393-6. PubMed ID: 24972428
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Protective effects of new femoral reaming techniques (Reamer irrigator aspirator, RIA I and II) on pulmonary function and posttraumatic contusion (CT morphology) - results from a standardized large animal model.
    Halvachizadeh S; Teuben M; Lempert M; Kalbas Y; Cesarovic N; Lipiski M; Benninger E; Cinelli P; Pfeifer R; Pape HC
    Injury; 2021 Jan; 52(1):26-31. PubMed ID: 33046248
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of the reamer shape on intraosseus pressure during closed intramedullary nailing of the unbroken femur: a preliminary report.
    Peter RE; Selz T; Koestli A
    Injury; 1993; 24 Suppl 3():S48-55. PubMed ID: 8168876
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Femoral neck fracture complicating intramedullary nailing of femoral shaft.
    Deep K; Sharp I; Hay SM
    Injury; 1999 Aug; 30(6):445-7. PubMed ID: 10645360
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Incarcerated Cortical Fragments in Intramedullary Nailing.
    Eastman JG; Firoozabadi R; Cook LE; Barei DP
    Orthopedics; 2016 May; 39(3):e582-6. PubMed ID: 27088352
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Aseptic femoral nonunion treated with exchange locked nailing with intramedullary augmentation cancellous bone graft.
    Wu CC
    J Orthop Surg Res; 2022 Jul; 17(1):339. PubMed ID: 35794570
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cardiopulmonary response to reamed intramedullary nailing of the femur comparing traditional reaming with a one-step reamer-irrigator-aspirator reaming system: an experimental study in pigs.
    Husebye EE; Lyberg T; Opdahl H; Laurvik H; Røise O
    J Trauma; 2010 Oct; 69(4):E6-14. PubMed ID: 20489666
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reverse wedge effect following intramedullary nailing of a basicervical trochanteric fracture variant combined with a mechanically compromised greater trochanter.
    Zhang Y; Hu J; Li X; Qin X
    BMC Musculoskelet Disord; 2020 Mar; 21(1):195. PubMed ID: 32222146
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The influence of a one-step reamer-irrigator-aspirator technique on the intramedullary pressure in the pig femur.
    Husebye EE; Lyberg T; Madsen JE; Eriksen M; Røise O
    Injury; 2006 Oct; 37(10):935-40. PubMed ID: 16934266
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reaming does not add significant time to intramedullary nailing of diaphyseal fractures of the tibia and femur.
    Crist BD; Wolinsky PR
    J Trauma; 2009 Oct; 67(4):727-34. PubMed ID: 19820578
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Technical innovations in medullary reaming: reamer design and intramedullary pressure increase.
    Müller CA; Baumgart F; Wahl D; Perren SM; Pfister U
    J Trauma; 2000 Sep; 49(3):440-5. PubMed ID: 11003320
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Systemic complications in intramedullary nailing].
    Wenda K; Runkel M
    Orthopade; 1996 Jun; 25(3):292-9. PubMed ID: 8766666
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Nonunion following intramedullary nailing of the femur with and without reaming. Results of a multicenter randomized clinical trial.
    Canadian Orthopaedic Trauma Society
    J Bone Joint Surg Am; 2003 Nov; 85(11):2093-6. PubMed ID: 14630836
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effects of femoral intramedullary reaming on pulmonary function in a sheep lung model.
    Duwelius PJ; Huckfeldt R; Mullins RJ; Shiota T; Woll TS; Lindsey KH; Wheeler D
    J Bone Joint Surg Am; 1997 Feb; 79(2):194-202. PubMed ID: 9052539
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Risks and results after simultaneous intramedullary nailing in bilateral femoral fractures: a retrospective study of 40 cases].
    Bonnevialle P; Cauhepe C; Alqoh F; Bellumore Y; Rongières M; Mansat M
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):598-607. PubMed ID: 11060434
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intramedullary nailing of femoral shaft fractures: current concepts.
    Ricci WM; Gallagher B; Haidukewych GJ
    J Am Acad Orthop Surg; 2009 May; 17(5):296-305. PubMed ID: 19411641
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [The effect of bone marrow embolization on the choice of procedure in the stabilization of femoral fractures].
    Wenda K; Runkel M; Rudig L; Degreif J
    Orthopade; 1995 Apr; 24(2):151-63. PubMed ID: 7753540
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.