156 related articles for article (PubMed ID: 37738807)
1. Impact of the confluence of cardiac motion and high spatial resolution on performance of ECG-gated imaging with an investigational photon-counting CT system: A phantom study.
Rajagopal JR; Farhadi F; Nikpanah M; Sahbaee P; Saboury B; Pritchard WF; Jones EC; Chen MY; Samei E
Phys Med; 2023 Oct; 114():102683. PubMed ID: 37738807
[TBL] [Abstract][Full Text] [Related]
2. Thin slice photon-counting CT coronary angiography compared to conventional CT: Objective image quality and clinical radiation dose assessment.
van der Bie J; Bos D; Dijkshoorn ML; Booij R; Budde RPJ; van Straten M
Med Phys; 2024 Apr; 51(4):2924-2932. PubMed ID: 38358113
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of Coronary Plaques and Stents with Conventional and Photon-counting CT: Benefits of High-Resolution Photon-counting CT.
Rajagopal JR; Farhadi F; Richards T; Nikpanah M; Sahbaee P; Shanbhag SM; Bandettini WP; Saboury B; Malayeri AA; Pritchard WF; Jones EC; Samei E; Chen MY
Radiol Cardiothorac Imaging; 2021 Oct; 3(5):e210102. PubMed ID: 34778782
[TBL] [Abstract][Full Text] [Related]
4. Quantifying lumen diameter in coronary artery stents with high-resolution photon counting detector CT and convolutional neural network denoising.
Koons EK; Thorne JE; Huber NR; Chang S; Rajendran K; McCollough CH; Leng S
Med Phys; 2023 Jul; 50(7):4173-4181. PubMed ID: 37069830
[TBL] [Abstract][Full Text] [Related]
5. Comprehensive evaluations of a prototype full field-of-view photon counting CT system through phantom studies.
Zhan X; Zhang R; Niu X; Hein I; Budden B; Wu S; Markov N; Clarke C; Qiang Y; Taguchi H; Nomura K; Muramatsu Y; Yu Z; Kobayashi T; Thompson R; Miyazaki H; Nakai H
Phys Med Biol; 2023 Aug; 68(17):. PubMed ID: 37506710
[No Abstract] [Full Text] [Related]
6. Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter.
Rajendran K; Voss BA; Zhou W; Tao S; DeLone DR; Lane JI; Weaver JM; Carlson ML; Fletcher JG; McCollough CH; Leng S
Invest Radiol; 2020 Feb; 55(2):91-100. PubMed ID: 31770297
[TBL] [Abstract][Full Text] [Related]
7. High-pitch, high temporal resolution, multi-energy cardiac imaging on a dual-source photon-counting-detector CT.
Ahmed Z; Campeau D; Gong H; Rajendran K; Rajiah P; McCollough C; Leng S
Med Phys; 2023 Mar; 50(3):1428-1435. PubMed ID: 36427356
[TBL] [Abstract][Full Text] [Related]
8. A methodology for incorporating a photon-counting CT system into routine clinical use.
Bache ST; Samei E
J Appl Clin Med Phys; 2023 Aug; 24(8):e14069. PubMed ID: 37389963
[TBL] [Abstract][Full Text] [Related]
9. Ultra-high-resolution spectral silicon-based photon-counting detector CT for coronary CT angiography: Initial results in a dynamic phantom.
Holmes TW; Yin Z; Stevens GM; Slavic S; Okerlund DR; Maltz JS; Pourmorteza A
J Cardiovasc Comput Tomogr; 2023; 17(5):341-344. PubMed ID: 37567802
[TBL] [Abstract][Full Text] [Related]
10. Stent appearance in a novel silicon-based photon-counting CT prototype: ex vivo phantom study in head-to-head comparison with conventional energy-integrating CT.
Verelst E; Buls N; De Mey J; Nieboer KH; Vandenbergh F; Crotty D; Deak P; Sundvall A; Holmin S; De Smet A; Provyn S; Van Gompel G
Eur Radiol Exp; 2023 Apr; 7(1):23. PubMed ID: 37097376
[TBL] [Abstract][Full Text] [Related]
11. High Spatial-Resolution Skull Base Imaging With Photon-Counting Computed Tomography and Energy-Integrating Computed Tomography: A Comparative Phantom Study.
Rajagopal JR; Schwartz FR; Solomon JB; Enterline DS; Samei E
J Comput Assist Tomogr; 2023 Jul-Aug 01; 47(4):613-620. PubMed ID: 37380149
[TBL] [Abstract][Full Text] [Related]
12. Photon-Counting Detector CT-Based Vascular Calcium Removal Algorithm: Assessment Using a Cardiac Motion Phantom.
Allmendinger T; Nowak T; Flohr T; Klotz E; Hagenauer J; Alkadhi H; Schmidt B
Invest Radiol; 2022 Jun; 57(6):399-405. PubMed ID: 35025834
[TBL] [Abstract][Full Text] [Related]
13. Virtual monochromatic images for coronary artery imaging with a spectral photon-counting CT in comparison to dual-layer CT systems: a phantom and a preliminary human study.
Greffier J; Si-Mohamed SA; Lacombe H; Labour J; Djabli D; Boccalini S; Varasteh M; Villien M; Yagil Y; Erhard K; Boussel L; Beregi JP; Douek PC
Eur Radiol; 2023 Aug; 33(8):5476-5488. PubMed ID: 36920517
[TBL] [Abstract][Full Text] [Related]
14. Effective Spatial Resolution of Photon Counting CT for Imaging of Trabecular Structures is Superior to Conventional Clinical CT and Similar to High Resolution Peripheral CT.
Thomsen FSL; Horstmeier S; Niehoff JH; Peña JA; Borggrefe J
Invest Radiol; 2022 Sep; 57(9):620-626. PubMed ID: 35318968
[TBL] [Abstract][Full Text] [Related]
15. Constrained one-step material decomposition reconstruction of head CT data from a silicon photon-counting prototype.
Schmidt TG; Sidky EY; Pan X; Barber RF; Grönberg F; Sjölin M; Danielsson M
Med Phys; 2023 Oct; 50(10):6008-6021. PubMed ID: 37523258
[TBL] [Abstract][Full Text] [Related]
16. Ultra-high-resolution photon-counting detector computed tomography of the lungs: Phantom and clinical assessment of radiation dose and image quality.
Chamberlin JH; Smith CD; Maisuria D; Parrish J; van Swol E; Mah E; Emrich T; Schoepf UJ; Varga-Szemes A; O'Doherty J; Munden RF; Tipnis SV; Baruah D; Kabakus IM
Clin Imaging; 2023 Dec; 104():110008. PubMed ID: 37862910
[TBL] [Abstract][Full Text] [Related]
17. A systematic task-based image quality assessment of photon-counting and energy integrating CT as a function of reconstruction kernel and phantom size.
Bhattarai M; Bache S; Abadi E; Samei E
Med Phys; 2024 Feb; 51(2):1047-1060. PubMed ID: 37469179
[TBL] [Abstract][Full Text] [Related]
18. Exploration of the pulse pileup effects in a clinical CdTe-based photon-counting computed tomography.
Bhattarai M; Bache S; Abadi E; Samei E
Med Phys; 2023 Nov; 50(11):6693-6703. PubMed ID: 37602816
[TBL] [Abstract][Full Text] [Related]
19. Deep silicon photon-counting CT: A first simulation-based study for assessing perceptual benefits across diverse anatomies.
Sharma S; Pal D; Abadi E; Segars P; Hsieh J; Samei E
Eur J Radiol; 2024 Feb; 171():111279. PubMed ID: 38194843
[TBL] [Abstract][Full Text] [Related]
20. Quarter-millimeter spectral coronary stent imaging with photon-counting CT: Initial experience.
Symons R; De Bruecker Y; Roosen J; Van Camp L; Cork TE; Kappler S; Ulzheimer S; Sandfort V; Bluemke DA; Pourmorteza A
J Cardiovasc Comput Tomogr; 2018; 12(6):509-515. PubMed ID: 30509378
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]