These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 37741986)

  • 21. Postprandial lipemia causes oxidative stress in dogs.
    Bonatto NCM; de Oliveira PL; Mancebo AM; Costa LR; Bosculo MRM; Bosco AM; Ciarlini PC; Floriano BP; de Barros LD; Almeida BFM
    Res Vet Sci; 2021 May; 136():277-286. PubMed ID: 33725655
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Managing hemolyzed samples in clinical laboratories.
    Simundic AM; Baird G; Cadamuro J; Costelloe SJ; Lippi G
    Crit Rev Clin Lab Sci; 2020 Jan; 57(1):1-21. PubMed ID: 31603708
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Resolving icteric interference by a novel photoisomerization device: Bilibox.
    Vera MA; Koch CD; El-Khoury JM
    Clin Biochem; 2023 May; 115():112-115. PubMed ID: 35882276
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Multicenter evaluation of the interference of hemoglobin, bilirubin and lipids on Synchron LX-20 assays.
    Steen G; Vermeer HJ; Naus AJ; Goevaerts B; Agricola PT; Schoenmakers CH
    Clin Chem Lab Med; 2006; 44(4):413-9. PubMed ID: 16599834
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of the interference of hemoglobin, bilirubin, and lipids on Roche Cobas 6000 assays.
    Ji JZ; Meng QH
    Clin Chim Acta; 2011 Aug; 412(17-18):1550-3. PubMed ID: 21575617
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Unreliable visual estimation of the incidence and amount of turbidity, hemolysis, and icterus in serum from hospitalized patients.
    Glick MR; Ryder KW; Glick SJ; Woods JR
    Clin Chem; 1989 May; 35(5):837-9. PubMed ID: 2720981
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Croatian laboratories have a good knowledge of the proper detection and management of hemolyzed, icteric and lipemic samples.
    Nikolac N; Celap I; Filipi P; Hemar M; Kocijancic M; Miler M; Simundic AM; Smolcic VS; Vrtaric A
    Clin Chem Lab Med; 2016 Mar; 54(3):419-25. PubMed ID: 26426892
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Interference in coagulation testing: focus on spurious hemolysis, icterus, and lipemia.
    Lippi G; Plebani M; Favaloro EJ
    Semin Thromb Hemost; 2013 Apr; 39(3):258-66. PubMed ID: 23229354
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A deep learning-based system for assessment of serum quality using sample images.
    Yang C; Li D; Sun D; Zhang S; Zhang P; Xiong Y; Zhao M; Qi T; Situ B; Zheng L
    Clin Chim Acta; 2022 Jun; 531():254-260. PubMed ID: 35421398
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effects of hemolysis, lipemia, hyperbilirrubinemia, and anticoagulants in canine C-reactive protein, serum amyloid A, and ceruloplasmin assays.
    Martínez-Subiela S; Cerón JJ
    Can Vet J; 2005 Jul; 46(7):625-9. PubMed ID: 16152718
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Icteric human samples: Icterus index and method of estimating an interference-free value for 16 biochemical analyses.
    Nicolay A; Lorec AM; Gomez G; Portugal H
    J Clin Lab Anal; 2018 Feb; 32(2):. PubMed ID: 28397988
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Ultracentrifugation for Coagulation Testing.
    Gosselin RC
    Methods Mol Biol; 2023; 2663():63-70. PubMed ID: 37204704
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Handling of lipemic samples in the clinical laboratory.
    Fernández Prendes C; Castro Castro MJ; Sánchez Navarro L; Rapún Mas L; Morales Indiano C; Arrobas Velilla T
    Adv Lab Med; 2023 Apr; 4(1):5-27. PubMed ID: 37359904
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Optimization of the Preanalytical Phase by Estimating Serum Indices Using an Automated Classifier.
    Herráez O; Velasco A; Escobar A; Asencio MA
    Clin Lab; 2020 Jan; 66(1):. PubMed ID: 32013367
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of visual vs. automated detection of lipemic, icteric and hemolyzed specimens: can we rely on a human eye?
    Simundic AM; Nikolac N; Ivankovic V; Ferenec-Ruzic D; Magdic B; Kvaternik M; Topic E
    Clin Chem Lab Med; 2009; 47(11):1361-5. PubMed ID: 19778291
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Establishing hemolysis, icterus, and lipemia interference limits for body fluid chemistry analytes measured on the Roche cobas instrument.
    Block DR; Lasho MA; Donato LJ; Meeusen JW
    Am J Clin Pathol; 2024 May; ():. PubMed ID: 38709595
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Correction of patient results for Beckman Coulter LX-20 assays affected by interference due to hemoglobin, bilirubin or lipids: a practical approach.
    Vermeer HJ; Steen G; Naus AJ; Goevaerts B; Agricola PT; Schoenmakers CH
    Clin Chem Lab Med; 2007; 45(1):114-9. PubMed ID: 17243928
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Markers of lipid peroxidation and α-tocopherol levels in the blood and neoplastic tissue of dogs with malignant mammary gland tumors.
    Karayannopoulou M; Fytianou A; Assaloumidis N; Psalla D; Constantinidis TC; Kaldrymidou E; Koutinas AF
    Vet Clin Pathol; 2013 Sep; 42(3):323-8. PubMed ID: 23906434
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of 8-hydroxydeoxyguanosine, thiobarbituric acid-reactive substances and total antioxidant status as possible disease markers in oesophageal malignancies.
    Diakowska D; Krzystek-Korpacka M; Lewandowski A; Grabowski K; Diakowski W
    Clin Biochem; 2008 Jul; 41(10-11):796-803. PubMed ID: 18433723
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Developing optimized automated rule sets for reporting hemolysis, icterus and lipemia based on a priori outcomes analysis.
    Boyd JM; Krause R; Waite G; Hui W; Yazdi E; Wilmink D; Seiden-Long I
    Clin Chim Acta; 2015 Oct; 450():31-8. PubMed ID: 26164383
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.