These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 37742087)

  • 1. Assessing the venous system: Correlation of mean systemic filling pressure with the venous excess ultrasound grading system in cardiac surgery.
    Utrilla-Alvarez JD; Gopar-Nieto R; García-Cruz E; Lazcano-Díaz E; Jiménez-Rodrìguez GM; Rojas-Velasco G; Manzur-Sandoval D
    Echocardiography; 2023 Nov; 40(11):1216-1226. PubMed ID: 37742087
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Prevalence of systemic venous congestion assessed by Venous Excess Ultrasound Grading System (VExUS) and association with acute kidney injury in a general ICU cohort: a prospective multicentric study.
    Andrei S; Bahr PA; Nguyen M; Bouhemad B; Guinot PG
    Crit Care; 2023 Jun; 27(1):224. PubMed ID: 37291662
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Venous Excess Ultrasound (VExUS Grading to Assess Perioperative Fluid Status for Noncardiac Surgeries: a Prospective Observational Pilot Study.
    Magin JC; Wrobel JR; An X; Acton J; Doyal A; Jia S; Krakowski JC; Schoenherr J; Serrano R; Flynn D; McLean D; Grant SA
    POCUS J; 2023; 8(2):223-229. PubMed ID: 38099161
    [No Abstract]   [Full Text] [Related]  

  • 4. Venous Congestion Assessed by Venous Excess Ultrasound (VExUS) and Acute Kidney Injury in Children with Right Ventricular Dysfunction.
    Natraj R; Bhaskaran AK; Rola P; Haycock K; Siuba MT; Ranjit S
    Indian J Crit Care Med; 2024 May; 28(5):447-452. PubMed ID: 38738193
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Correlation between the VExUS score and right atrial pressure: a pilot prospective observational study.
    Longino A; Martin K; Leyba K; Siegel G; Gill E; Douglas IS; Burke J
    Crit Care; 2023 May; 27(1):205. PubMed ID: 37237315
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Prospective Evaluation of Venous Excess Ultrasound for Estimation of Venous Congestion.
    Longino A; Martin K; Leyba K; Siegel G; Thai TN; Riscinti M; Douglas IS; Gill E; Burke J
    Chest; 2024 Mar; 165(3):590-600. PubMed ID: 37813180
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Combination of Inferior Vena Cava Diameter, Hepatic Venous Flow, and Portal Vein Pulsatility Index: Venous Excess Ultrasound Score (VEXUS Score) in Predicting Acute Kidney Injury in Patients with Cardiorenal Syndrome: A Prospective Cohort Study.
    Bhardwaj V; Vikneswaran G; Rola P; Raju S; Bhat RS; Jayakumar A; Alva A
    Indian J Crit Care Med; 2020 Sep; 24(9):783-789. PubMed ID: 33132560
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Unlocking the Potential of VExUS in Assessing Venous Congestion: The Art of Doing It Right.
    Koratala A; Romero-González G; Soliman-Aboumarie H; Kazory A
    Cardiorenal Med; 2024; 14(1):350-374. PubMed ID: 38815571
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of various surrogate markers for venous congestion in predicting acute kidney injury following cardiac surgery: A cohort study.
    Li ZT; Huang DB; Zhao JF; Li H; Fu SQ; Wang W
    J Crit Care; 2024 Feb; 79():154441. PubMed ID: 37812993
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Venous Excess Ultrasound for Fluid Assessment in Complex Cardiac Patients With Acute Kidney Injury.
    Kanitkar S; Soni K; Vaishnav B
    Cureus; 2024 Aug; 16(8):e66003. PubMed ID: 39221348
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Venous excess ultrasound score and acute kidney injury in patients with acute coronary syndrome.
    Viana-Rojas JA; Argaiz E; Robles-Ledesma M; Arias-Mendoza A; Nájera-Rojas NA; Alonso-Bringas AP; De Los Ríos-Arce LF; Armenta-Rodriguez J; Gopar-Nieto R; Briseño-De la Cruz JL; González-Pacheco H; Sierra-Lara Martinez D; Gonzalez-Salido J; Lopez-Gil S; Araiza-Garaygordobil D
    Eur Heart J Acute Cardiovasc Care; 2023 Jul; 12(7):413-419. PubMed ID: 37154067
    [TBL] [Abstract][Full Text] [Related]  

  • 12. EARLY TRAJECTORY OF VENOUS EXCESS ULTRASOUND SCORE IS ASSOCIATED WITH CLINICAL OUTCOMES OF GENERAL ICU PATIENTS.
    Trigkidis KK; Siempos II; Kotanidou A; Zakynthinos S; Routsi C; Kokkoris S
    Shock; 2024 Mar; 61(3):400-405. PubMed ID: 38517247
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quantifying systemic congestion with Point-Of-Care ultrasound: development of the venous excess ultrasound grading system.
    Beaubien-Souligny W; Rola P; Haycock K; Bouchard J; Lamarche Y; Spiegel R; Denault AY
    Ultrasound J; 2020 Apr; 12(1):16. PubMed ID: 32270297
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Venous excess ultrasonography (VExUS) captures dynamic changes in volume status surrounding hemodialysis: A multicenter prospective observational study.
    Leyba K; Longino A; Ormesher R; Krienke M; Van Ochten N; Zimmerman K; McCormack L; Martin K; Thai T; Furgeson S; Teitelbaum I; Burke J; Douglas I; Gill E
    Res Sq; 2024 Apr; ():. PubMed ID: 38659788
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Feasibility and Utility of the Venous Excess Ultrasound Score to Detect and Grade Central Venous Pressure Elevation in Critically Ill Children.
    Menéndez-Suso JJ; Rodríguez-Álvarez D; Sánchez-Martín M
    J Ultrasound Med; 2023 Jan; 42(1):211-220. PubMed ID: 35811405
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Femoral vein pulsatility: a simple tool for venous congestion assessment.
    Bhardwaj V; Rola P; Denault A; Vikneswaran G; Spiegel R
    Ultrasound J; 2023 May; 15(1):24. PubMed ID: 37165284
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of venous congestion with venous excess ultrasound score in the prognosis of acute heart failure in the emergency department: a prospective study.
    Landi I; Guerritore L; Iannaccone A; Ricotti A; Rola P; Garrone M
    Eur Heart J Open; 2024 Sep; 4(5):oeae050. PubMed ID: 39234262
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Utility of bedside ultrasound derived hepatic and renal parenchymal flow patterns to guide management of acute kidney injury.
    Jury D; Shaw AD
    Curr Opin Crit Care; 2021 Dec; 27(6):587-592. PubMed ID: 34636777
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transesophageal echocardiographic acquisition of the venous excess ultrasound exam-a case series and technical description.
    Waldron NH; Pandompatam G; Sareyyupoglu B; Kalagara H
    Can J Anaesth; 2024 Mar; 71(3):422-430. PubMed ID: 38286981
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Utility of the Venous Excess Ultrasound (VEXUS) score to track dynamic change in volume status in patients undergoing fluid removal during haemodialysis - the ACUVEX study.
    Wong A; Olusanya O; Watchorn J; Bramham K; Hutchings S
    Ultrasound J; 2024 Mar; 16(1):23. PubMed ID: 38538806
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.