These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 37746855)

  • 1. Comment to: Extensive analytical evaluation of the performances of the new DiaSys PCT assay and comparison with Elecsys B·R·A·H·M·S PCT test on Roche Cobas and B·R·A·H·M·S PCT-sensitive Kryptor.
    Masetto T; Grimmler M
    Clin Chem Lab Med; 2024 Jan; 62(2):e48-e50. PubMed ID: 37746855
    [No Abstract]   [Full Text] [Related]  

  • 2. Extensive analytical evaluation of the performances of the new DiaSys PCT assay and comparison with Elecsys B·R·A·H·M·S PCT test on Roche Cobas and B·R·A·H·M·S PCT-sensitive Kryptor.
    Di Deo P; Vantaggiato C; Di Modugno A; Licari D; Savina PF; Zagliani A; Viganò C; Grimaldi G; Frassanito A; Lettera T; De Corato P; Ammirabile M; Ferraris Fusarini C; De Liso F; Maregnani A; Silvani I; Taverriti TPS; Ceriotti F; Vidali M
    Clin Chem Lab Med; 2024 Jan; 62(2):e44-e47. PubMed ID: 37531078
    [No Abstract]   [Full Text] [Related]  

  • 3. Reply to: Analytical evaluation of the performances of Diazyme and BRAHMS procalcitonin applied to Roche Cobas in comparison with BRAHMS PCT-sensitive Kryptor.
    Yuan C
    Clin Chem Lab Med; 2017 Nov; 56(1):e5-e6. PubMed ID: 29031019
    [No Abstract]   [Full Text] [Related]  

  • 4. Analytical evaluation of the performances of Diazyme and BRAHMS procalcitonin applied to Roche Cobas in comparison with BRAHMS PCT-sensitive Kryptor.
    Ceriotti F; Marino I; Motta A; Carobene A
    Clin Chem Lab Med; 2017 Nov; 56(1):162-169. PubMed ID: 28809746
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of procalcitonin immunoassay concordance near clinical decision points.
    Chambliss AB; Hayden J; Colby JM
    Clin Chem Lab Med; 2019 Aug; 57(9):1414-1421. PubMed ID: 30763263
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Bioanalytical Performance of a New Particle-Enhanced Method for Measuring Procalcitonin.
    Dupuy AM; Bargnoux AS; Larcher R; Merindol A; Masetto T; Badiou S; Cristol JP
    Diagnostics (Basel); 2020 Jul; 10(7):. PubMed ID: 32646054
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of a new procalcitonin assay for the Siemens ADVIA Centaur with the established method on the B.R.A.H.M.S Kryptor.
    Sanders RJ; Schoorl M; Dekker E; Snijders D; Boersma WG; Ten Boekel E
    Clin Lab; 2011; 57(5-6):415-20. PubMed ID: 21755834
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of a novel automated DiaSys procalcitonin immunoassay with four different BRAHMS-partnered immunoassays.
    Eidizadeh A; Wiederhold M; Schnelle M; Binder L
    Pract Lab Med; 2022 May; 30():e00274. PubMed ID: 35465623
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of the novel ARCHITECT procalcitonin assay with established procalcitonin assay systems.
    Soh A; Binder L; Clough M; Hernandez MH; Lefèvre G; Mostert K; Nguyen TB; Otte KM; Portakal O; Sandri MS; Yen JL; Huang J; Beshiri A
    Pract Lab Med; 2018 Nov; 12():e00110. PubMed ID: 30519621
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Method Verification Shows a Negative Bias between 2 Procalcitonin Methods at Medical Decision Concentrations.
    Gruzdys V; Cahoon K; Pearson L; Lehman CM
    J Appl Lab Med; 2019 Jul; 4(1):69-77. PubMed ID: 31639709
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validation of the procalcitonin (PCT) assay: Experience in a pediatric hospital.
    Agarwal S; Akbas N; Soundar EP; Gonzalez G; Devaraj S
    Clin Biochem; 2015 Sep; 48(13-14):886-90. PubMed ID: 25895483
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical performance of calcitonin and procalcitonin Elecsys
    Giovanella L; Fontana M; Keller F; Verburg FA; Ceriani L
    Clin Chem Lab Med; 2021 Mar; 59(4):743-747. PubMed ID: 33085633
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multicenter evaluation of a new immunoassay for procalcitonin measurement on the Kryptor System.
    Steinbach G; Rau B; Debard AL; Javourez JF; Bienvenu J; Ponzio A; Bonfà A; Hubl W; Demant T; Külpmann WR; Buchholz J; Schumann G
    Clin Chem Lab Med; 2004 Apr; 42(4):440-9. PubMed ID: 15147156
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analytical and clinical performance of the Advansure i3 procalcitonin assay.
    Heo W; Park HD
    Scand J Clin Lab Invest; 2021 Nov; 81(7):546-551. PubMed ID: 34601986
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rapid and Sensitive Lateral Flow Immunoassay Method for Procalcitonin (PCT) Based on Time-Resolved Immunochromatography.
    Shao XY; Wang CR; Xie CM; Wang XG; Liang RL; Xu WW
    Sensors (Basel); 2017 Feb; 17(3):. PubMed ID: 28264502
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analytical evaluation of Diazyme procalcitonin (PCT) latex-enhanced immunoturbidimetric assay on Beckman Coulter AU5800.
    Dipalo M; Buonocore R; Gnocchi C; Picanza A; Aloe R; Lippi G
    Clin Chem Lab Med; 2015 Mar; 53(4):593-7. PubMed ID: 25536668
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analytical evaluation of Lumipulse® BRAHMS PCT CLEIA assay and clinical performances in an unselected population as compared with central lab PCT assay.
    Dupuy AM; Né M; Bargnoux AS; Badiou S; Cristol JP
    Clin Biochem; 2017 Mar; 50(4-5):248-250. PubMed ID: 27838408
    [TBL] [Abstract][Full Text] [Related]  

  • 18. National external quality assessment and direct method comparison reflect crucial deviations of Procalcitonin measurements in Germany.
    Masetto T; Eidizadeh A; Peter C; Grimmler M
    Clin Chim Acta; 2022 Apr; 529():67-75. PubMed ID: 35167843
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Evaluation of measurement method of a bacterial sepsis marker, procalcitonin].
    Adachi S; Nakao K
    Rinsho Biseibutshu Jinsoku Shindan Kenkyukai Shi; 2010; 21(2):107-9. PubMed ID: 22096868
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Multicenter comparison of automated procalcitonin immunoassays.
    Dipalo M; Guido L; Micca G; Pittalis S; Locatelli M; Motta A; Bianchi V; Callegari T; Aloe R; Da Rin G; Lippi G
    Pract Lab Med; 2015 Aug; 2():22-28. PubMed ID: 28932801
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.