These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
128 related articles for article (PubMed ID: 37749000)
21. Venous Flow Coupler in Head and Neck Free Flap Reconstruction. Troob SH; Self Q; Gerecci D; Hodgson M; González-Castro J; Petrisor D; Wax MK Otolaryngol Head Neck Surg; 2021 Mar; 164(3):574-579. PubMed ID: 32895011 [TBL] [Abstract][Full Text] [Related]
22. [Application of microvascular coupling device for arterial anastomosis in head and neck reconstruction]. Yu M; Chen ZW; Huang SY; Zhang DS Shanghai Kou Qiang Yi Xue; 2019 Aug; 28(4):435-438. PubMed ID: 31792489 [TBL] [Abstract][Full Text] [Related]
23. [Mechanical venous microanastomosis using a double ring eversion system in reconstructive surgery]. Prade V; Parrau G; Seguin P; Champin J; Alix T Rev Stomatol Chir Maxillofac Chir Orale; 2013 Nov; 114(5):299-303. PubMed ID: 23856034 [TBL] [Abstract][Full Text] [Related]
24. Protocol for a systematic review of venous coupler devices versus hand-sewn anastomosis for microsurgical free flap reconstruction. Rodi T; Geierlehner A; Mosahebi A; Tanos G; Wormald JCR Syst Rev; 2018 Nov; 7(1):186. PubMed ID: 30424802 [TBL] [Abstract][Full Text] [Related]
25. Microsurgical anastomosis using anterior versus posterior tibial artery in lower limb free tissue transfer. Theile H; Wiper J; Noblet T; Watson L; Wagels M ANZ J Surg; 2022 May; 92(5):1190-1195. PubMed ID: 35180330 [TBL] [Abstract][Full Text] [Related]
26. Differences in free flaps' reconstructions with and without coupling device for venous anastomosis. Rysz M; Kissin F Otolaryngol Pol; 2021 Sep; 76(1):6-12. PubMed ID: 35380117 [TBL] [Abstract][Full Text] [Related]
27. Should 1 or 2 Venous Anastomoses Be Done in Microsurgical Flap Transfer? Khan S; Khan Z; Ali M; Shaikh SA; Rahman MF Ann Plast Surg; 2020 Nov; 85(5):522-526. PubMed ID: 32118636 [TBL] [Abstract][Full Text] [Related]
28. Outcomes and reliability of the flow coupler in postoperative monitoring of head and neck free flaps. Fujiwara RJT; Dibble JM; Larson SV; Pierce ML; Mehra S Laryngoscope; 2018 Apr; 128(4):812-817. PubMed ID: 28988465 [TBL] [Abstract][Full Text] [Related]
30. Microvascular anastomotic coupler for venous end-to-side anastomoses in head and neck reconstructive surgery. Kisser U; Koepernik S Eur Arch Otorhinolaryngol; 2023 Oct; 280(10):4709-4712. PubMed ID: 37528315 [TBL] [Abstract][Full Text] [Related]
31. [Thrombosis of sewn vs. coupled anastomoses in microvascular head and neck reconstructions]. Sievert M; Koch M; Goncalves M; Richter D; Tamse R; Mueller SK; Gostian AO; Traxdorf M; Harréus U; Iro H Laryngorhinootologie; 2021 Jun; 100(6):453-459. PubMed ID: 32927485 [TBL] [Abstract][Full Text] [Related]
32. Less Is More? Impact of Single Venous Anastomosis on the Intrinsic Transit Time of Free Flaps. Dornseifer U; Kleeberger C; Kimelman M; Kargl L; Holm C; Moog P; Ninkovic M J Reconstr Microsurg; 2017 Feb; 33(2):137-142. PubMed ID: 27855467 [No Abstract] [Full Text] [Related]
33. One versus two venous anastomoses in microsurgical head and neck reconstruction: a cumulative meta-analysis. Christianto S; Lau A; Li KY; Yang WF; Su YX Int J Oral Maxillofac Surg; 2018 May; 47(5):585-594. PubMed ID: 29395670 [TBL] [Abstract][Full Text] [Related]
34. Microvascular coupler device versus hand-sewn venous anastomosis: A systematic review of the literature and data meta-analysis. Maruccia M; Fatigato G; Elia R; Ragusa LA; Vestita MG; Nacchiero E; Robusto F; Nicoli F; Pedro Ciudad ; Giudice G Microsurgery; 2020 Jul; 40(5):608-617. PubMed ID: 32246807 [TBL] [Abstract][Full Text] [Related]
35. Use of couplers for vascular anastomoses in 601 free flaps for reconstruction of defects of the head and neck: technique and two-year retrospective clinical study. Assoumane A; Wang L; Liu K; Shang ZJ Br J Oral Maxillofac Surg; 2017 Jun; 55(5):461-464. PubMed ID: 28465039 [TBL] [Abstract][Full Text] [Related]
36. Salvage arterial anastomosis using a microvascular coupler in head and neck free flap reconstruction. Genther DJ; Day AT; Rana K; Richmon JD Laryngoscope; 2017 Mar; 127(3):642-644. PubMed ID: 27753100 [TBL] [Abstract][Full Text] [Related]
37. Matched Comparison of Microsurgical Anastomoses Performed with Loupe Magnification versus Operating Microscope in Traumatic Lower Extremity Reconstruction. Stranix JT; Azoury SC; Lee ZH; Kozak G; Plana N; Thanik VD; Saadeh PB; Levine JP; Levin LS; Kovach SJ Plast Reconstr Surg; 2020 Jan; 145(1):235-240. PubMed ID: 31609285 [TBL] [Abstract][Full Text] [Related]
38. Reliability of venous couplers for microanastomosis of the venae comitantes in free radial forearm flaps for head and neck reconstruction. Patel SA; Pang JH; Natoli N; Gallagher S; Topham N J Reconstr Microsurg; 2013 Sep; 29(7):433-6. PubMed ID: 23588548 [TBL] [Abstract][Full Text] [Related]
39. Microvascular anastomotic coupler assessment in head and neck reconstruction. Frederick JW; Sweeny L; Carroll WR; Rosenthal EL Otolaryngol Head Neck Surg; 2013 Jul; 149(1):67-70. PubMed ID: 23585150 [TBL] [Abstract][Full Text] [Related]
40. Bedside Neck Exploration for Venous Flow Coupler Signal Loss in Postoperative Free Tissue Transfer Monitoring. Davis KP; Gardner JR; Dunlap QA; Vural EA; Sunde J; Moreno MA Otolaryngol Head Neck Surg; 2022 Aug; 167(2):242-247. PubMed ID: 34699280 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]