These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 37753473)

  • 1. Quantitative Analysis of Clot Deposition on Extracorporeal Life Support Membrane Oxygenators Using Digital and Scanning Electron Microscopy Imaging Techniques.
    Zang Y; Roberts TR; Harea GT; Beely BM; Perez LOJ; Ande S; Batchinsky M; Lee JH; Thrailkill MA; Reynolds MM; Batchinsky AI
    Bio Protoc; 2023 Sep; 13(18):e4814. PubMed ID: 37753473
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Electron Microscopy as a Tool for Assessment of Anticoagulation Strategies During Extracorporeal Life Support: The Proof Is on the Membrane.
    Beely BM; Campbell JE; Meyer A; Langer T; Negaard K; Chung KK; Cap AP; Cancio LC; Batchinsky AI
    ASAIO J; 2016; 62(5):525-32. PubMed ID: 27258220
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Combination of polycarboxybetaine coating and factor XII inhibitor reduces clot formation while preserving normal tissue coagulation during extracorporeal life support.
    Naito N; Ukita R; Wilbs J; Wu K; Lin X; Carleton NM; Roberts K; Jiang S; Heinis C; Cook KE
    Biomaterials; 2021 May; 272():120778. PubMed ID: 33812214
    [TBL] [Abstract][Full Text] [Related]  

  • 4. 72-Hour in vivo evaluation of nitric oxide generating artificial lung gas exchange fibers in sheep.
    Lai A; Demarest CT; Do-Nguyen CC; Ukita R; Skoog DJ; Carleton NM; Amoako KA; Montoya PJ; Cook KE
    Acta Biomater; 2019 May; 90():122-131. PubMed ID: 30953800
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vitro drug adsorption and plasma free hemoglobin levels associated with hollow fiber oxygenators in the extracorporeal life support (ECLS) circuit.
    Preston TJ; Hodge AB; Riley JB; Leib-Sargel C; Nicol KK
    J Extra Corpor Technol; 2007 Dec; 39(4):234-7. PubMed ID: 18293808
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Heparin-Free Extracorporeal Life Support Using Tethered Liquid Perfluorocarbon: A Feasibility and Efficacy Study.
    Roberts TR; Harea GT; Singha P; Sieck KN; Beely BM; Wendorff DS; Choi JH; Ande S; Handa H; Batchinsky AI
    ASAIO J; 2020 Jul; 66(7):809-817. PubMed ID: 31453831
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Technical Indicators to Evaluate the Degree of Large Clot Formation Inside the Membrane Fiber Bundle of an Oxygenator in an In Vitro Setup.
    Kaesler A; Hesselmann F; Zander MO; Schlanstein PC; Wagner G; Bruners P; Schmitz-Rode T; Steinseifer U; Arens J
    Artif Organs; 2019 Feb; 43(2):159-166. PubMed ID: 30084492
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of Thrombotic Deposits in Extracorporeal Membrane Oxygenators by High-resolution Microcomputed Tomography: A Feasibility Study.
    Birkenmaier C; Dornia C; Lehle K; Müller T; Gruber M; Philipp A; Krenkel L
    ASAIO J; 2020 Aug; 66(8):922-928. PubMed ID: 32740353
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Computed tomography angiography as an adjunct to computational fluid dynamics for prediction of oxygenator thrombus formation.
    Conway RG; Zhang J; Jeudy J; Evans C; Li T; Wu ZJ; Griffith BP
    Perfusion; 2021 Apr; 36(3):285-292. PubMed ID: 32723149
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pediatric and neonatal extracorporeal life support technology component utilization: are US clinicians implementing new technology?
    Reed-Thurston D; Qiu F; Ündar A; Haidet KK; Shenberger J
    Artif Organs; 2012 Jul; 36(7):607-15. PubMed ID: 22626005
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analysis of thrombotic deposits in extracorporeal membrane oxygenators by multidetector computed tomography.
    Dornia C; Philipp A; Bauer S; Lubnow M; Müller T; Lehle K; Schmid C; Müller-Wille R; Wiggermann P; Stroszczynski C; Schreyer AG
    ASAIO J; 2014; 60(6):652-6. PubMed ID: 25158889
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hollow Fiber Oxygenator Composition Has a Significant Impact on Failure Rates in Neonates on Extracorporeal Membrane Oxygenation: A Retrospective Analysis.
    Daniel JM; Bernard PA; Skinner SC; Bhandary P; Ruzic A; Bacon MK; Ballard HO
    J Pediatr Intensive Care; 2018 Mar; 7(1):7-13. PubMed ID: 31073461
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro hemodynamic evaluation of a novel pulsatile extracorporeal life support system: impact of perfusion modes and circuit components on energy loss.
    Wang S; Kunselman AR; Clark JB; Ündar A
    Artif Organs; 2015 Jan; 39(1):59-66. PubMed ID: 25586773
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tethered Liquid Perfluorocarbon Coating for 72 Hour Heparin-Free Extracorporeal Life Support.
    Roberts TR; Choi JH; Wendorff DS; Harea GT; Beely BM; Sieck KN; Douglass ME; Singha P; Dean JB; Handa H; Batchinsky AI
    ASAIO J; 2021 Jul; 67(7):798-808. PubMed ID: 33534236
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of conventional nonpulsatile and novel pulsatile extracorporeal life support systems in a simulated pediatric extracorporeal life support model.
    Wang S; Evenson A; Chin BJ; Kunselman AR; Ündar A
    Artif Organs; 2015 Jan; 39(1):E1-9. PubMed ID: 24660832
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Advances in extracorporeal membrane oxygenator design for artificial placenta technology.
    Blauvelt DG; Abada EN; Oishi P; Roy S
    Artif Organs; 2021 Mar; 45(3):205-221. PubMed ID: 32979857
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Trends and emerging technologies in extracorporeal life support: results of the 2006 ECLS survey.
    Sievert AN; Shackelford AG; McCall MM
    J Extra Corpor Technol; 2009 Jun; 41(2):73-8. PubMed ID: 19681303
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Visualization of thrombotic deposits in extracorporeal membrane oxygenation devices using multidetector computed tomography: a feasibility study.
    Dornia C; Philipp A; Bauer S; Hoffstetter P; Lehle K; Schmid C; Lubnow M; Stroszczynski C; Schreyer AG
    ASAIO J; 2013; 59(4):439-41. PubMed ID: 23820285
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Extended Cellular Deposits on Gas Exchange Capillaries Are Not an Indicator of Clot Formation: Analysis of Different Membrane Oxygenators.
    Dropco I; Philipp A; Foltan M; Lunz D; Lubnow M; Lehle K
    ASAIO J; 2023 Apr; 69(4):e134-e141. PubMed ID: 36780695
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of oxygenator selection on hemodynamic energy indicators under pulsatile and nonpulsatile flow in a neonatal extracorporeal life support model.
    Vasavada R; Khan S; Qiu F; Kunselman A; Undar A
    Artif Organs; 2011 Jun; 35(6):E101-7. PubMed ID: 21623841
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.