These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. COMPLEMENTARY TECHNIQUES OF PERCUTANEOUS CLOSURE OF DUCTUS ARTERIOSUS USING DETACHABLE COOK COILS AND AMPLATZER DEVICES. Yuko-Jowi CA; Okello CA; Mutai L East Afr Med J; 2013 Jul; 90(7):214-21. PubMed ID: 26862619 [TBL] [Abstract][Full Text] [Related]
5. Contemporary outcomes of percutaneous closure of patent ductus arteriosus in adolescents and adults. P S; Jose J; George OK Indian Heart J; 2018; 70(2):308-315. PubMed ID: 29716712 [TBL] [Abstract][Full Text] [Related]
6. [Percutaneous closure of the patent ductus arteriosus in children with the Amplatzer Duct Occluder II]. Parra-Bravo JR; Osuna-Izaguirre MA; Beirana-Palencia L; Gálvez-Cancino F; Martínez-Monterrosas C; Lazo-Cárdenas C; Reyes-Vargas C Arch Cardiol Mex; 2014; 84(3):171-6. PubMed ID: 24998666 [TBL] [Abstract][Full Text] [Related]
7. Transcatheter Closure of Patent Ductus Arteriosus in Children with the Occlutech Duct Occluder. Bilici M; Demir F; Akın A; Türe M; Balık H; Kuyumcu M Pediatr Cardiol; 2017 Dec; 38(8):1598-1605. PubMed ID: 28828684 [TBL] [Abstract][Full Text] [Related]
8. Transcatheter retrieval of atrial septal defect and patent ductus arteriosus occluder: a guidance for device retrieval based on comprehensive bench tests. Fujii T; Sugiyama H; Kanazawa H; Hara H; Muneuchi J; Yazaki S Cardiol Young; 2023 Sep; 33(9):1597-1605. PubMed ID: 36093848 [TBL] [Abstract][Full Text] [Related]
9. Percutaneous closure of an aneurysmal patent ductus arteriosus in an adult. Schussler JM; Choi JW Catheter Cardiovasc Interv; 2010 Dec; 76(7):1041-3. PubMed ID: 20927782 [TBL] [Abstract][Full Text] [Related]
10. Outcomes of transcatheter closure of patent ductus arteriosus with the off-label use of large occluders (≥16 mm). Kanabar K; Bootla D; Kaur N; Pruthvi CR; Krishnappa D; Santosh K; Guleria V; Rohit MK Indian Heart J; 2020; 72(2):107-112. PubMed ID: 32534682 [TBL] [Abstract][Full Text] [Related]
11. Transcatheter closure of hemodynamic significant patent ductus arteriosus in 32 premature infants by amplatzer ductal occluder additional size-ADOIIAS. Morville P; Akhavi A Catheter Cardiovasc Interv; 2017 Oct; 90(4):612-617. PubMed ID: 28471089 [TBL] [Abstract][Full Text] [Related]
12. [Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children]. Parra-Bravo JR; Apolonio-Martínez A; Estrada-Loza Mde J; Beirana-Palencia LG; Ramírez-Portillo CI Arch Cardiol Mex; 2015; 85(3):188-94. PubMed ID: 25700578 [TBL] [Abstract][Full Text] [Related]
13. Transcatheter closure of elongated and pulmonary hypertensive patent arterial duct in infants using Amplatzer vascular plug II. Jain SM; Pradhan PM; Sen S; Dalvi BV Cardiol Young; 2020 Feb; 30(2):243-248. PubMed ID: 31996273 [TBL] [Abstract][Full Text] [Related]
14. Distensibility of the ductus arteriosus in neonates and young infants undergoing transcatheter closure. Nagasawa K; Muneuchi J; Sugitani Y; Ezaki H; Doi H; Furuta T; Kobayashi M; Watanabe M Heart Vessels; 2022 Mar; 37(3):513-516. PubMed ID: 34406441 [TBL] [Abstract][Full Text] [Related]
15. Transcatheter occlusion of the patent ductus arteriosus in premature infants weighing less than 1200 g. Morville P; Douchin S; Bouvaist H; Dauphin C Arch Dis Child Fetal Neonatal Ed; 2018 May; 103(3):F198-F201. PubMed ID: 29066474 [TBL] [Abstract][Full Text] [Related]
16. [Transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder in children: initial and one-year results]. Parra-Bravo JR; Cruz-Ramírez A; Toxqui-Terán A; Juan-Martínez E; Chávez-Fernández AA; Lazo-Cárdenas C; Beirana-Palencia L; Estrada-Flores J Arch Cardiol Mex; 2009; 79(2):114-20. PubMed ID: 19722381 [TBL] [Abstract][Full Text] [Related]
17. Comparison of the results of transcatheter closure of patent ductus arteriosus with newer Amplatzer devices. Liddy S; Oslizlok P; Walsh KP Catheter Cardiovasc Interv; 2013 Aug; 82(2):253-9. PubMed ID: 23427043 [TBL] [Abstract][Full Text] [Related]
18. Cardi-O-Fix duct occluder versus Amplatzer duct occluder for closure of patent ductus arteriosus. Celebi A; Demir IH; Saritaş T; Dedeoğlu R; Yucel IK; Demir F; Erdem A Catheter Cardiovasc Interv; 2013 Nov; 82(6):961-7. PubMed ID: 23592558 [TBL] [Abstract][Full Text] [Related]
19. Trans-catheter closure of large PDA in adult patients with Amplatzer device: case series. Khajali Z; Firouzi A; Ghaderian H; Aliramezany M Cardiol Young; 2022 Jan; 32(1):161-164. PubMed ID: 34233780 [TBL] [Abstract][Full Text] [Related]
20. Closure of large patent ductus arteriosus using the Amplatzer Septal Occluder. García-Montes JA; Camacho-Castro A; Sandoval-Jones JP; Buendía-Hernández A; Calderón-Colmenero J; Patiño-Bahena E; Zabal C Cardiol Young; 2015 Mar; 25(3):491-5. PubMed ID: 24555910 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]