BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 37769882)

  • 21. Spatial-temporal perfusion patterns of the human liver assessed by pseudo-continuous arterial spin labeling MRI.
    Martirosian P; Pohmann R; Schraml C; Schwartz M; Kuestner T; Schwenzer NF; Scheffler K; Nikolaou K; Schick F
    Z Med Phys; 2019 May; 29(2):173-183. PubMed ID: 30266458
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Test-retest reliability and reproducibility of long-label pseudo-continuous arterial spin labeling.
    Lin T; Qu J; Zuo Z; Fan X; You H; Feng F
    Magn Reson Imaging; 2020 Nov; 73():111-117. PubMed ID: 32717203
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of three-dimensional pseudo-continuous arterial spin labeling perfusion imaging with gradient-echo and spin-echo dynamic susceptibility contrast MRI.
    Wong AM; Yan FX; Liu HL
    J Magn Reson Imaging; 2014 Feb; 39(2):427-33. PubMed ID: 23677620
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Liver perfusion MRI in a rodent model of cirrhosis: Agreement with bulk-flow phase-contrast MRI and noninvasive evaluation of inflammation in chronic liver disease using flow-sensitive alternating inversion recovery arterial spin labelling and tissue T1.
    Chouhan MD; Ramasawmy R; Bainbridge A; Campbell-Washburn A; Halligan S; Davies N; Walker-Samuel S; Lythgoe MF; Mookerjee RP; Taylor SA
    NMR Biomed; 2021 Feb; 34(2):e4423. PubMed ID: 33029872
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Improved pseudo-continuous arterial spin labeling for mapping brain perfusion.
    Nezamzadeh M; Matson GB; Young K; Weiner MW; Schuff N
    J Magn Reson Imaging; 2010 Jun; 31(6):1419-27. PubMed ID: 20512895
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pancreatic perfusion and arterial-transit-time quantification using pseudocontinuous arterial spin labeling at 3T.
    Taso M; Guidon A; Zhao L; Mortele KJ; Alsop DC
    Magn Reson Med; 2019 Jan; 81(1):542-550. PubMed ID: 30229559
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Reproducibility of multiphase pseudo-continuous arterial spin labeling and the effect of post-processing analysis methods.
    Fazlollahi A; Bourgeat P; Liang X; Meriaudeau F; Connelly A; Salvado O; Calamante F
    Neuroimage; 2015 Aug; 117():191-201. PubMed ID: 26026814
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Measuring the labeling efficiency of pseudocontinuous arterial spin labeling.
    Chen Z; Zhang X; Yuan C; Zhao X; van Osch MJP
    Magn Reson Med; 2017 May; 77(5):1841-1852. PubMed ID: 27174204
    [TBL] [Abstract][Full Text] [Related]  

  • 29. High temporal resolution arterial spin labeling MRI with whole-brain coverage by combining time-encoding with Look-Locker and simultaneous multi-slice imaging.
    van der Plas MCE; Teeuwisse WM; Schmid S; Chappell M; van Osch MJP
    Magn Reson Med; 2019 Jun; 81(6):3734-3744. PubMed ID: 30828873
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Demonstration of pulmonary perfusion heterogeneity induced by gravity and lung inflation using arterial spin labeling.
    Fan L; Liu SY; Xiao XS; Sun F
    Eur J Radiol; 2010 Feb; 73(2):249-54. PubMed ID: 19121903
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Reliability of two-dimensional and three-dimensional pseudo-continuous arterial spin labeling perfusion MRI in elderly populations: comparison with 15O-water positron emission tomography.
    Kilroy E; Apostolova L; Liu C; Yan L; Ringman J; Wang DJ
    J Magn Reson Imaging; 2014 Apr; 39(4):931-9. PubMed ID: 24038544
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Acceleration of vessel-selective dynamic MR Angiography by pseudocontinuous arterial spin labeling in combination with Acquisition of ConTRol and labEled images in the Same Shot (ACTRESS).
    Suzuki Y; Okell TW; Fujima N; van Osch MJP
    Magn Reson Med; 2019 May; 81(5):2995-3006. PubMed ID: 30506957
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Evaluation of segmented 3D acquisition schemes for whole-brain high-resolution arterial spin labeling at 3 T.
    Vidorreta M; Balteau E; Wang Z; De Vita E; Pastor MA; Thomas DL; Detre JA; Fernández-Seara MA
    NMR Biomed; 2014 Nov; 27(11):1387-96. PubMed ID: 25263944
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Myocardial perfusion assessment in humans using steady-pulsed arterial spin labeling.
    Capron T; Troalen T; Robert B; Jacquier A; Bernard M; Kober F
    Magn Reson Med; 2015 Oct; 74(4):990-8. PubMed ID: 25263761
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Characterization of pseudo-continuous arterial spin labeling: Simulations and experimental validation.
    Lorenz K; Mildner T; Schlumm T; Möller HE
    Magn Reson Med; 2018 Mar; 79(3):1638-1649. PubMed ID: 28653470
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Combined angiography and perfusion using radial imaging and arterial spin labeling.
    Okell TW
    Magn Reson Med; 2019 Jan; 81(1):182-194. PubMed ID: 30024066
    [TBL] [Abstract][Full Text] [Related]  

  • 37. High-resolution mouse kidney perfusion imaging by pseudo-continuous arterial spin labeling at 11.75T.
    Duhamel G; Prevost V; Girard OM; Callot V; Cozzone PJ
    Magn Reson Med; 2014 Mar; 71(3):1186-96. PubMed ID: 23568817
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Volumetric abdominal perfusion measurement using a pseudo-randomly sampled 3D fast-spin-echo (FSE) arterial spin labeling (ASL) sequence and compressed sensing reconstruction.
    Taso M; Zhao L; Guidon A; Litwiller DV; Alsop DC
    Magn Reson Med; 2019 Aug; 82(2):680-692. PubMed ID: 30953396
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Quantification of cerebral perfusion and cerebrovascular reserve using Turbo-QUASAR arterial spin labeling MRI.
    Zhao MY; Václavů L; Petersen ET; Biemond BJ; Sokolska MJ; Suzuki Y; Thomas DL; Nederveen AJ; Chappell MA
    Magn Reson Med; 2020 Feb; 83(2):731-748. PubMed ID: 31513311
    [TBL] [Abstract][Full Text] [Related]  

  • 40. MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR.
    Mai VM; Berr SS
    J Magn Reson Imaging; 1999 Mar; 9(3):483-7. PubMed ID: 10194721
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.