BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

267 related articles for article (PubMed ID: 37771127)

  • 1. Comparison between Three-Dimensional Printed Titanium and PEEK Cages for Cervical and Lumbar Interbody Fusion: A Prospective Controlled Trial.
    Deng Z; Zou Q; Wang L; Wang L; Xiu P; Feng G; Song Y; Yang X
    Orthop Surg; 2023 Nov; 15(11):2889-2900. PubMed ID: 37771127
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of Long-Term Outcomes between the n-HA/PA66 Cage and the PEEK Cage Used in Transforaminal Lumbar Interbody Fusion for Lumbar Degenerative Disease: A Matched-Pair Case Control Study.
    Zhang Z; Hu BW; Wang L; Yang HL; Li T; Liu LM; Yang X; Song YM
    Orthop Surg; 2023 Jan; 15(1):152-161. PubMed ID: 36398388
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative Analysis of Radiologic Outcomes Between Polyetheretherketone and Three-Dimensional-Printed Titanium Cages After Transforaminal Lumbar Interbody Fusion.
    Sultana T; Hossain M; Jeong JH; Im S
    World Neurosurg; 2023 Nov; 179():e241-e255. PubMed ID: 37611804
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Promotion of higher rates of early fusion using activated titanium versus polyetheretherketone cages in adults undergoing 1- and 2-level transforaminal lumbar interbody fusion procedures: a randomized controlled trial.
    Toop N; Dhaliwal J; Gifford CS; Gibbs D; Keister A; Miracle S; Forghani R; Grossbach AJ; Farhadi HF
    J Neurosurg Spine; 2023 Nov; 39(5):709-718. PubMed ID: 37542447
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of Long-term Follow-Up of n-HA PA66 Cage and PEEK Cage of Lumbar Interbody Fusion in Multi-level Degenerative Lumbar Diseases: A Stepwise Propensity Score Matching Analysis.
    Li Q; Gao Q; Wang L; Liu L; Yang H; Song Y
    Orthop Surg; 2024 Jan; 16(1):17-28. PubMed ID: 37953456
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Comparison of Polyetheretherketone and Titanium-Coated Polyetheretherketone in Minimally Invasive Transforaminal Lumbar Interbody Fusion: A Randomized Clinical Trial.
    Singhatanadgige W; Tangchitcharoen N; Kerr SJ; Tanasansomboon T; Yingsakmongkol W; Kotheeranurak V; Limthongkul W
    World Neurosurg; 2022 Dec; 168():e471-e479. PubMed ID: 36216250
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Efficacy analysis of autologous facet joint bone block in lumbar interbody fusion of osteoporosis patients].
    Wang DW; Wang HD; Li L; Yin X; Huang W; Guo JD; Yang YF; Liu YH; Zheng Y
    Beijing Da Xue Xue Bao Yi Xue Ban; 2023 Oct; 55(5):899-909. PubMed ID: 37807746
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of anterior cervical discectomy and fusion (ACDF) using self-locking stand-alone polyetheretherketone (PEEK) cage with ACDF using cage and plate in the treatment of three-level cervical degenerative spondylopathy: a retrospective study with 2-year follow-up.
    Chen Y; Lü G; Wang B; Li L; Kuang L
    Eur Spine J; 2016 Jul; 25(7):2255-62. PubMed ID: 26906171
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Outcomes of interbody fusion cages used in 1 and 2-levels anterior cervical discectomy and fusion: titanium cages versus polyetheretherketone (PEEK) cages.
    Niu CC; Liao JC; Chen WJ; Chen LH
    J Spinal Disord Tech; 2010 Jul; 23(5):310-6. PubMed ID: 20124907
    [TBL] [Abstract][Full Text] [Related]  

  • 10. PEEK versus titanium cages in lateral lumbar interbody fusion: a comparative analysis of subsidence.
    Campbell PG; Cavanaugh DA; Nunley P; Utter PA; Kerr E; Wadhwa R; Stone M
    Neurosurg Focus; 2020 Sep; 49(3):E10. PubMed ID: 32871573
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of fusion rates following transforaminal lumbar interbody fusion using polyetheretherketone cages or titanium cages with transpedicular instrumentation.
    Nemoto O; Asazuma T; Yato Y; Imabayashi H; Yasuoka H; Fujikawa A
    Eur Spine J; 2014 Oct; 23(10):2150-5. PubMed ID: 25015180
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Titanium interlayer-mediated hydroxyapatite-coated polyetheretherketone cage in transforaminal lumbar interbody fusion surgery.
    Zhu C; He M; Mao L; Yang H; Hu B; Zhang L; Feng G; Liu L; Song Y
    BMC Musculoskelet Disord; 2021 Nov; 22(1):918. PubMed ID: 34724952
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of polyetheretherketone cages with femoral cortical bone allograft as a single-piece interbody spacer in transforaminal lumbar interbody fusion.
    Cutler AR; Siddiqui S; Mohan AL; Hillard VH; Cerabona F; Das K
    J Neurosurg Spine; 2006 Dec; 5(6):534-9. PubMed ID: 17176018
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Anterior cervical discectomy and fusion: comparison of titanium and polyetheretherketone cages.
    Cabraja M; Oezdemir S; Koeppen D; Kroppenstedt S
    BMC Musculoskelet Disord; 2012 Sep; 13():172. PubMed ID: 22978810
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison Between Acrylic Cage and Polyetheretherketone (PEEK) Cage in Single-level Anterior Cervical Discectomy and Fusion: A Randomized Clinical Trial.
    Farrokhi MR; Nikoo Z; Gholami M; Hosseini K
    Clin Spine Surg; 2017 Feb; 30(1):38-46. PubMed ID: 28107234
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Titanium vs. polyetheretherketone (PEEK) interbody fusion: Meta-analysis and review of the literature.
    Seaman S; Kerezoudis P; Bydon M; Torner JC; Hitchon PW
    J Clin Neurosci; 2017 Oct; 44():23-29. PubMed ID: 28736113
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Early Outcomes of Three-Dimensional-Printed Porous Titanium versus Polyetheretherketone Cage Implantation for Stand-Alone Lateral Lumbar Interbody Fusion in the Treatment of Symptomatic Adjacent Segment Degeneration.
    Adl Amini D; Moser M; Oezel L; Zhu J; Okano I; Shue J; Sama AA; Cammisa FP; Girardi FP; Hughes AP
    World Neurosurg; 2022 Jun; 162():e14-e20. PubMed ID: 34863938
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Graft subsidence and reoperation after lateral lumbar interbody fusion: a propensity score-matched and cost analysis of polyetheretherketone versus 3D-printed porous titanium interbodies.
    Alan N; Deng H; Muthiah N; Vodovotz L; Dembinski R; Guha D; Agarwal N; Ozpinar A; Hamilton DK; Kanter AS; Okonkwo DO
    J Neurosurg Spine; 2023 Aug; 39(2):187-195. PubMed ID: 37178027
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of cage subsidence in standalone lateral lumbar interbody fusion: novel 3D-printed titanium versus polyetheretherketone (PEEK) cage.
    Adl Amini D; Okano I; Oezel L; Zhu J; Chiapparelli E; Shue J; Sama AA; Cammisa FP; Girardi FP; Hughes AP
    Eur Spine J; 2021 Aug; 30(8):2377-2384. PubMed ID: 34215921
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The postoperative clinical effects of utilizing 3D printed (Ti6Al4V) interbody fusion cages in posterior lumbar fusion: A retrospective cohort study.
    Wang Z; Zhang D; Zhang Z; Miao J
    Medicine (Baltimore); 2024 Jun; 103(25):e38431. PubMed ID: 38905365
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.