138 related articles for article (PubMed ID: 37774710)
1. Dense speed-of-sound shift imaging for ultrasonic thermometry.
Grutman T; Ilovitsh T
Phys Med Biol; 2023 Oct; 68(21):. PubMed ID: 37774710
[No Abstract] [Full Text] [Related]
2. Spatial and Temporal Control of Hyperthermia Using Real Time Ultrasonic Thermal Strain Imaging with Motion Compensation, Phantom Study.
Foiret J; Ferrara KW
PLoS One; 2015; 10(8):e0134938. PubMed ID: 26244783
[TBL] [Abstract][Full Text] [Related]
3. Creation and characterization of an ultrasound and CT phantom for noninvasive ultrasound thermometry calibration.
Chun-Yen Lai ; Kruse DE; Ferrara KW; Caskey CF
IEEE Trans Biomed Eng; 2014 Feb; 61(2):502-12. PubMed ID: 24107918
[TBL] [Abstract][Full Text] [Related]
4. Feasibility of ultrasound tomography-guided localized mild hyperthermia using a ring transducer: Ex vivo and in silico studies.
Pattyn A; Kratkiewicz K; Alijabbari N; Carson PL; Littrup P; Fowlkes JB; Duric N; Mehrmohammadi M
Med Phys; 2022 Sep; 49(9):6120-6136. PubMed ID: 35759729
[TBL] [Abstract][Full Text] [Related]
5. Interleaved Mapping of Temperature and Longitudinal Relaxation Rate to Monitor Drug Delivery During Magnetic Resonance-Guided High-Intensity Focused Ultrasound-Induced Hyperthermia.
Kneepkens E; Heijman E; Keupp J; Weiss S; Nicolay K; Grüll H
Invest Radiol; 2017 Oct; 52(10):620-630. PubMed ID: 28598900
[TBL] [Abstract][Full Text] [Related]
6. MRI monitoring of temperature and displacement for transcranial focus ultrasound applications.
Ozenne V; Constans C; Bour P; Santin MD; Valabrègue R; Ahnine H; Pouget P; Lehéricy S; Aubry JF; Quesson B
Neuroimage; 2020 Jan; 204():116236. PubMed ID: 31597085
[TBL] [Abstract][Full Text] [Related]
7. Magnetic resonance thermometry and its biological applications - Physical principles and practical considerations.
Odéen H; Parker DL
Prog Nucl Magn Reson Spectrosc; 2019 Feb; 110():34-61. PubMed ID: 30803693
[TBL] [Abstract][Full Text] [Related]
8. Quantitative MR thermometry based on phase-drift correction PRF shift method at 0.35 T.
Chen Y; Ge M; Ali R; Jiang H; Huang X; Qiu B
Biomed Eng Online; 2018 Apr; 17(1):39. PubMed ID: 29631576
[TBL] [Abstract][Full Text] [Related]
9. Ultrasound monitoring of temperature change in liver tissue during laser thermotherapy: 10 degrees C intervals.
Mokhtari-Dizaji M; Gorji-Ara T; Ghanaeati H; Kalbasi M
Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():2130-3. PubMed ID: 18002409
[TBL] [Abstract][Full Text] [Related]
10. Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging.
Viallon M; Terraz S; Roland J; Dumont E; Becker CD; Salomir R
Med Phys; 2010 Apr; 37(4):1491-506. PubMed ID: 20443470
[TBL] [Abstract][Full Text] [Related]
11. Ultrasound thermal monitoring with an external ultrasound source for customized bipolar RF ablation shapes.
Kim Y; Audigier C; Ziegle J; Friebe M; Boctor EM
Int J Comput Assist Radiol Surg; 2018 Jun; 13(6):815-826. PubMed ID: 29619610
[TBL] [Abstract][Full Text] [Related]
12. Monitoring MR-guided high intensity focused ultrasound therapy using transient supersonic shear wave MR-elastography.
Ishak O; Breton E; Choquet K; Josset A; Cabras P; Vappou J
Phys Med Biol; 2023 Jan; 68(3):. PubMed ID: 36595333
[No Abstract] [Full Text] [Related]
13. Determining temperature distribution in tissue in the focal plane of the high (>100 W/cm(2)) intensity focused ultrasound beam using phase shift of ultrasound echoes.
Karwat P; Kujawska T; Lewin PA; Secomski W; Gambin B; Litniewski J
Ultrasonics; 2016 Feb; 65():211-9. PubMed ID: 26498063
[TBL] [Abstract][Full Text] [Related]
14. Noninvasive calibrated tissue temperature estimation using backscattered energy of acoustic harmonics.
Shaswary E; Assi H; Yang C; Kumaradas JC; Kolios MC; Peyman G; Tavakkoli J
Ultrasonics; 2021 Jul; 114():106406. PubMed ID: 33691235
[TBL] [Abstract][Full Text] [Related]
15. Combined passive acoustic mapping and magnetic resonance thermometry for monitoring phase-shift nanoemulsion enhanced focused ultrasound therapy.
Crake C; Meral FC; Burgess MT; Papademetriou IT; McDannold NJ; Porter TM
Phys Med Biol; 2017 Jul; 62(15):6144-6163. PubMed ID: 28590938
[TBL] [Abstract][Full Text] [Related]
16. An adaptive targeting algorithm for magnetic resonance-guided high-intensity focused ultrasound controlled hyperthermia.
Wong SM; Luo P; Keunen B; Pichardo S; Drake JM; Waspe AC
Med Phys; 2023 Jun; 50(6):3347-3358. PubMed ID: 37058533
[TBL] [Abstract][Full Text] [Related]
17. Monitoring of thermal therapy based on shear modulus changes: I. shear wave thermometry.
Arnal B; Pernot M; Tanter M
IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Feb; 58(2):369-78. PubMed ID: 21342822
[TBL] [Abstract][Full Text] [Related]
18. Magnetic resonance temperature imaging of laser-induced thermotherapy using proton resonance frequency shift: evaluation of different sequences in phantom and porcine brain at 7 T.
Xu G; Zhao Z; Xu K; Zhu J; Roe AW; Xu B; Zhang X; Li J; Xu D
Jpn J Radiol; 2022 Aug; 40(8):768-780. PubMed ID: 35430679
[TBL] [Abstract][Full Text] [Related]
19. Three-dimensional spatial and temporal temperature imaging in gel phantoms using backscattered ultrasound.
Anand A; Savéry D; Hall C
IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Jan; 54(1):23-31. PubMed ID: 17225797
[TBL] [Abstract][Full Text] [Related]
20. Hybrid referenceless and multibaseline subtraction MR thermometry for monitoring thermal therapies in moving organs.
Grissom WA; Rieke V; Holbrook AB; Medan Y; Lustig M; Santos J; McConnell MV; Pauly KB
Med Phys; 2010 Sep; 37(9):5014-26. PubMed ID: 20964221
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]