These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 3777664)

  • 1. Inductive plethysmography--a facilitated postural calibration technique for rapid and accurate tidal volume determination in low birth weight premature newborns.
    Stefano JL; Spitzer AR; Baumgart S; Davis JM; Fox WW
    Am Rev Respir Dis; 1986 Nov; 134(5):1020-4. PubMed ID: 3777664
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of respiratory inductive plethysmography in infants weighing less than 1,500 grams.
    Wilkes DL; Revow M; Bryan MH; England SJ
    Am Rev Respir Dis; 1987 Aug; 136(2):416-9. PubMed ID: 3619201
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tidal volume measurements in newborns using respiratory inductive plethysmography.
    Adams JA; Zabaleta IA; Stroh D; Johnson P; Sackner MA
    Am Rev Respir Dis; 1993 Sep; 148(3):585-88. PubMed ID: 8368627
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of respiratory inductive plethysmograph over wide range of rib cage and abdominal compartmental contributions to tidal volume in normal subjects and in patients with chronic obstructive pulmonary disease.
    Gonzalez H; Haller B; Watson HL; Sackner MA
    Am Rev Respir Dis; 1984 Aug; 130(2):171-4. PubMed ID: 6465670
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of calibration methods for respiratory inductive plethysmography in infants.
    Revow MD; England SJ; Stogryn HA; Wilkes DL
    J Appl Physiol (1985); 1987 Nov; 63(5):1853-61. PubMed ID: 3693219
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Postural changes in rib cage and abdominal volume-motion coefficients and their effect on the calibration of a respiratory inductance plethysmograph.
    Zimmerman PV; Connellan SJ; Middleton HC; Tabona MV; Goldman MD; Pride N
    Am Rev Respir Dis; 1983 Feb; 127(2):209-14. PubMed ID: 6830037
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Calibration of respiratory inductive plethysmograph during natural breathing.
    Sackner MA; Watson H; Belsito AS; Feinerman D; Suarez M; Gonzalez G; Bizousky F; Krieger B
    J Appl Physiol (1985); 1989 Jan; 66(1):410-20. PubMed ID: 2917945
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Estimation of tidal ventilation in preterm and term newborn infants using electromagnetic inductance plethysmography.
    Williams EM; Pickerd N; Eriksen M; Øygarden K; Kotecha S
    Physiol Meas; 2011 Nov; 32(11):1833-45. PubMed ID: 22027661
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Respiratory induction plethysmography (Respitrace): an evaluation of its use in the infant.
    Duffty P; Spriet L; Bryan MH; Bryan AC
    Am Rev Respir Dis; 1981 May; 123(5):542-6. PubMed ID: 7235376
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Positioning effects on lung function and breathing pattern in premature newborns.
    Gouna G; Rakza T; Kuissi E; Pennaforte T; Mur S; Storme L
    J Pediatr; 2013 Jun; 162(6):1133-7, 1137.e1. PubMed ID: 23312684
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cross-sectional changes in lung volume measured by electrical impedance tomography are representative for the whole lung in ventilated preterm infants.
    van der Burg PS; Miedema M; de Jongh FH; Frerichs I; van Kaam AH
    Crit Care Med; 2014 Jun; 42(6):1524-30. PubMed ID: 24561568
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of breath size and posture on calibration of the respiratory inductive plethysmograph by multiple linear regression.
    Verschakelen JA; Deschepper K; Clarysse I; Demedts M
    Eur Respir J; 1989 Jan; 2(1):71-7. PubMed ID: 2707404
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Importance of breath size in calibrating the respiratory inductive plethysmograph.
    Millman RP; Chung DC; Shore ET
    Chest; 1986 Jun; 89(6):840-5. PubMed ID: 3709249
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurement of ventilation in children using the respiratory inductive plethysmograph.
    Tabachnik E; Muller N; Toye B; Levison H
    J Pediatr; 1981 Dec; 99(6):895-9. PubMed ID: 7310582
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Validation of respiratory inductive plethysmography using different calibration procedures.
    Chadha TS; Watson H; Birch S; Jenouri GA; Schneider AW; Cohn MA; Sackner MA
    Am Rev Respir Dis; 1982 Jun; 125(6):644-9. PubMed ID: 7091869
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Calibration of the respiratory inductive plethysmograph with the single position graphic technique. Accuracy in different behavior states in lambs.
    Warren RH; Fewell JE; Alderson SH
    Chest; 1988 Aug; 94(2):325-8. PubMed ID: 3396411
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reliability of respiratory inductive plethysmography for measuring tidal volume during exercise.
    Caretti DM; Pullen PV; Premo LA; Kuhlmann WD
    Am Ind Hyg Assoc J; 1994 Oct; 55(10):918-23. PubMed ID: 7977031
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Calibration of computer-assisted (Respicomp) respiratory inductive plethysmography in newborns.
    Warren RH; Alderson SH
    Am Rev Respir Dis; 1985 Apr; 131(4):564-7. PubMed ID: 3838868
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessment of tidal volume over time in preterm infants using respiratory inductance plethysmography, The CHIME Study Group. Collaborative Home Infant Monitoring Evaluation.
    Brooks LJ; DiFiore JM; Martin RJ
    Pediatr Pulmonol; 1997 Jun; 23(6):429-33. PubMed ID: 9220525
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of various models for respiratory inductance plethysmography calibration.
    Strömberg NO; Dahlbäck GO; Gustafsson PM
    J Appl Physiol (1985); 1993 Mar; 74(3):1206-11. PubMed ID: 8482659
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.