1. Inductive plethysmography--a facilitated postural calibration technique for rapid and accurate tidal volume determination in low birth weight premature newborns. Stefano JL; Spitzer AR; Baumgart S; Davis JM; Fox WW Am Rev Respir Dis; 1986 Nov; 134(5):1020-4. PubMed ID: 3777664 [TBL] [Abstract][Full Text] [Related]
2. Evaluation of respiratory inductive plethysmography in infants weighing less than 1,500 grams. Wilkes DL; Revow M; Bryan MH; England SJ Am Rev Respir Dis; 1987 Aug; 136(2):416-9. PubMed ID: 3619201 [TBL] [Abstract][Full Text] [Related]
3. Tidal volume measurements in newborns using respiratory inductive plethysmography. Adams JA; Zabaleta IA; Stroh D; Johnson P; Sackner MA Am Rev Respir Dis; 1993 Sep; 148(3):585-88. PubMed ID: 8368627 [TBL] [Abstract][Full Text] [Related]
4. Accuracy of respiratory inductive plethysmograph over wide range of rib cage and abdominal compartmental contributions to tidal volume in normal subjects and in patients with chronic obstructive pulmonary disease. Gonzalez H; Haller B; Watson HL; Sackner MA Am Rev Respir Dis; 1984 Aug; 130(2):171-4. PubMed ID: 6465670 [TBL] [Abstract][Full Text] [Related]
5. Comparison of calibration methods for respiratory inductive plethysmography in infants. Revow MD; England SJ; Stogryn HA; Wilkes DL J Appl Physiol (1985); 1987 Nov; 63(5):1853-61. PubMed ID: 3693219 [TBL] [Abstract][Full Text] [Related]
6. Postural changes in rib cage and abdominal volume-motion coefficients and their effect on the calibration of a respiratory inductance plethysmograph. Zimmerman PV; Connellan SJ; Middleton HC; Tabona MV; Goldman MD; Pride N Am Rev Respir Dis; 1983 Feb; 127(2):209-14. PubMed ID: 6830037 [TBL] [Abstract][Full Text] [Related]
7. Calibration of respiratory inductive plethysmograph during natural breathing. Sackner MA; Watson H; Belsito AS; Feinerman D; Suarez M; Gonzalez G; Bizousky F; Krieger B J Appl Physiol (1985); 1989 Jan; 66(1):410-20. PubMed ID: 2917945 [TBL] [Abstract][Full Text] [Related]
8. Estimation of tidal ventilation in preterm and term newborn infants using electromagnetic inductance plethysmography. Williams EM; Pickerd N; Eriksen M; Øygarden K; Kotecha S Physiol Meas; 2011 Nov; 32(11):1833-45. PubMed ID: 22027661 [TBL] [Abstract][Full Text] [Related]
9. Respiratory induction plethysmography (Respitrace): an evaluation of its use in the infant. Duffty P; Spriet L; Bryan MH; Bryan AC Am Rev Respir Dis; 1981 May; 123(5):542-6. PubMed ID: 7235376 [TBL] [Abstract][Full Text] [Related]
10. Positioning effects on lung function and breathing pattern in premature newborns. Gouna G; Rakza T; Kuissi E; Pennaforte T; Mur S; Storme L J Pediatr; 2013 Jun; 162(6):1133-7, 1137.e1. PubMed ID: 23312684 [TBL] [Abstract][Full Text] [Related]
11. Cross-sectional changes in lung volume measured by electrical impedance tomography are representative for the whole lung in ventilated preterm infants. van der Burg PS; Miedema M; de Jongh FH; Frerichs I; van Kaam AH Crit Care Med; 2014 Jun; 42(6):1524-30. PubMed ID: 24561568 [TBL] [Abstract][Full Text] [Related]
12. The effect of breath size and posture on calibration of the respiratory inductive plethysmograph by multiple linear regression. Verschakelen JA; Deschepper K; Clarysse I; Demedts M Eur Respir J; 1989 Jan; 2(1):71-7. PubMed ID: 2707404 [TBL] [Abstract][Full Text] [Related]
13. Importance of breath size in calibrating the respiratory inductive plethysmograph. Millman RP; Chung DC; Shore ET Chest; 1986 Jun; 89(6):840-5. PubMed ID: 3709249 [TBL] [Abstract][Full Text] [Related]
14. Measurement of ventilation in children using the respiratory inductive plethysmograph. Tabachnik E; Muller N; Toye B; Levison H J Pediatr; 1981 Dec; 99(6):895-9. PubMed ID: 7310582 [TBL] [Abstract][Full Text] [Related]
15. Validation of respiratory inductive plethysmography using different calibration procedures. Chadha TS; Watson H; Birch S; Jenouri GA; Schneider AW; Cohn MA; Sackner MA Am Rev Respir Dis; 1982 Jun; 125(6):644-9. PubMed ID: 7091869 [TBL] [Abstract][Full Text] [Related]
16. Calibration of the respiratory inductive plethysmograph with the single position graphic technique. Accuracy in different behavior states in lambs. Warren RH; Fewell JE; Alderson SH Chest; 1988 Aug; 94(2):325-8. PubMed ID: 3396411 [TBL] [Abstract][Full Text] [Related]
17. Reliability of respiratory inductive plethysmography for measuring tidal volume during exercise. Caretti DM; Pullen PV; Premo LA; Kuhlmann WD Am Ind Hyg Assoc J; 1994 Oct; 55(10):918-23. PubMed ID: 7977031 [TBL] [Abstract][Full Text] [Related]
18. Calibration of computer-assisted (Respicomp) respiratory inductive plethysmography in newborns. Warren RH; Alderson SH Am Rev Respir Dis; 1985 Apr; 131(4):564-7. PubMed ID: 3838868 [TBL] [Abstract][Full Text] [Related]
19. Assessment of tidal volume over time in preterm infants using respiratory inductance plethysmography, The CHIME Study Group. Collaborative Home Infant Monitoring Evaluation. Brooks LJ; DiFiore JM; Martin RJ Pediatr Pulmonol; 1997 Jun; 23(6):429-33. PubMed ID: 9220525 [TBL] [Abstract][Full Text] [Related]