These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

85 related articles for article (PubMed ID: 3778721)

  • 21. Experimental study on various methods of assisted circulation.
    Petrovsky BV; Shumakov VI
    J Cardiovasc Surg (Torino); 1969; 10(5):366-76. PubMed ID: 5365326
    [No Abstract]   [Full Text] [Related]  

  • 22. Chronic effect of left ventricular assist pumping on right ventricular function.
    Fukuda S; Takano H; Taenaka Y; Nakatani T; Noda H; Kinoshita M; Akutsu T; Takeuchi A
    ASAIO Trans; 1988; 34(3):712-5. PubMed ID: 3196588
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Functional heart replacement with the spindle pump: first results.
    Hager J; Brandstaetter F; Klima G; Koller J; Baum M; Unger F
    ASAIO Trans; 1990; 36(3):M379-82. PubMed ID: 2252704
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Automatic control and regulation of two rollerpumps for biventricular bypass.
    Marinow N; Hennig E; Frank J; Baer P; Keilbach H; Bücherl ES
    Life Support Syst; 1983; 1 Suppl 1():37-40. PubMed ID: 6336446
    [No Abstract]   [Full Text] [Related]  

  • 25. Hemodynamic effects of right ventricular assist pumping.
    Chiang BY; Ye CH; Gu YJ; Wang YS
    Int J Artif Organs; 1988 Jul; 11(4):265-71. PubMed ID: 3410568
    [No Abstract]   [Full Text] [Related]  

  • 26. A hemodynamic study of the biventricular bypass total artificial heart with special reference to intrarenal flow distribution.
    Ishino K
    Jpn J Surg; 1991 May; 21(3):312-21. PubMed ID: 1857034
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Left ventricular oxygen consumption and organ blood flow distribution during pulsatile ventricular assist.
    Pantalos GM; Marks JD; Riebman JB; Everett SD; Burns GL; Burton NA; DePaulis R
    ASAIO Trans; 1988; 34(3):356-60. PubMed ID: 3196533
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Hemodynamic response to exercise during chronic ventricular fibrillation and nonpulsatile biventricular bypass (BVB).
    Valdés F; Golding LR; Harasaki H; Takatani S; Jacobs G; Nosé Y
    Trans Am Soc Artif Intern Organs; 1981; 27():449-53. PubMed ID: 7331110
    [No Abstract]   [Full Text] [Related]  

  • 29. Paracorporeal assistance system for restoring cardiac activity.
    Tolpekin VE; Koblov LF; Kuvaev AE; Gasanov EK
    Artif Organs; 1987 Feb; 11(1):26-30. PubMed ID: 3566580
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Peristaltic bypass type of heart assist device. I. Acute hemodynamic studies.
    Takano H; Takagi H; Farish CA; Akutsu T
    Surgery; 1970 Oct; 68(4):676-84. PubMed ID: 5473045
    [No Abstract]   [Full Text] [Related]  

  • 31. Maintaining the circulation with only the left pump after total artificial heart replacement.
    Hennig E; Weidemann H; Keilbach H; Schiessler A; Stelter U; Baer P; Bücherl ES
    Life Support Syst; 1983; 1 Suppl 1():1-4. PubMed ID: 6336388
    [No Abstract]   [Full Text] [Related]  

  • 32. Mechanical assistance in severe experimental cardiogenic shock.
    Moulopoulos SD; Stamatelopoulos SF; Tsoutsos DA; Saridakis NS; Economides KN; Adractas AJ
    ASAIO Trans; 1987; 33(3):212-6. PubMed ID: 3675946
    [No Abstract]   [Full Text] [Related]  

  • 33. A new right ventricular assist device. The extracorporeal pulsatile assist device (EPAD).
    Whalen RL; Hurford WE; Skoskiewicz M; Wonders TR; Zapol WM
    ASAIO Trans; 1987; 33(3):222-6. PubMed ID: 3675948
    [No Abstract]   [Full Text] [Related]  

  • 34. Urgent implantation of the Berlin Heart Excor biventricular assist device as a total artificial heart in a patient with single ventricle circulation.
    Valeske K; Yerebakan C; Mueller M; Akintuerk H
    J Thorac Cardiovasc Surg; 2014 May; 147(5):1712-4. PubMed ID: 24521952
    [No Abstract]   [Full Text] [Related]  

  • 35. Predictors for weaning patients from ventricular assist devices (VADs).
    Termuhlen DF; Swartz MT; Pennington DG; Samuels LD; McBride LR; Kanter KR; Ruzevich SA
    ASAIO Trans; 1987; 33(3):683-8. PubMed ID: 3676003
    [No Abstract]   [Full Text] [Related]  

  • 36. Automated microprocessor controlled combined cardiac assist in profound biventricular failure.
    Phillipe E; Clark JW; Peterson R; Ellis JR; Landé A
    Trans Am Soc Artif Intern Organs; 1980; 26():432-7. PubMed ID: 7245528
    [No Abstract]   [Full Text] [Related]  

  • 37. [Anatomical and hemodynamic evolution at midpoint follow-up with the assisted heart in heterotopic heart transplantation. Apropos of 21 cases].
    Dor V; Jourdan J; Bourlon F; Elbèze JP; Grinneiser D; Isetta C; Montiglio F
    Arch Mal Coeur Vaiss; 1986 Jun; 79(7):1037-44. PubMed ID: 3096226
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Pulsatile versus non-pulsatile mechanical circulatory assistance].
    von Segesser LK; Leskosek B; Redha F; Hess O; Tjon-A-Meeuw L; Tornic M; Turina M
    Helv Chir Acta; 1988 Nov; 55(4):483-8. PubMed ID: 3215784
    [No Abstract]   [Full Text] [Related]  

  • 39. Physiological characteristics of an electrohydraulic ventricular assist system.
    Kung RT; Singh PI; de Sieyes DC; Cumming RD; Adams BB; Leicher FG; Magrassi P; Buckley MJ; Austen WG; Lederman DM
    Life Support Syst; 1983; 1 Suppl 1():5-8. PubMed ID: 6336461
    [No Abstract]   [Full Text] [Related]  

  • 40. [Contribution to the laterally different behavior of heart hemodynamics. An electrokymographic pulsation study].
    Siegel M
    Arch Klin Med; 1966; 212(3):251-60. PubMed ID: 5974125
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.