These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 37792485)

  • 1. State of the Art in Radiostereometric Analysis for Tibial Baseplate Migration and Future Research Directions.
    Niesen AE; Hull ML
    J Biomech Eng; 2023 Dec; 145(12):. PubMed ID: 37792485
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Risk of tibial baseplate loosening is low in patients following unrestricted kinematic alignment total knee arthroplasty using a cruciate-retaining medial conforming insert: A study using radiostereometric analysis at 2 years.
    Niesen AE; Tirumalai PA; Howell SM; Hull ML
    Knee Surg Sports Traumatol Arthrosc; 2024 Mar; 32(3):693-703. PubMed ID: 38415963
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Propagation of registration error into maximum total point motion to analyze tibial baseplate stability at six months using marker-based and model-based RSA.
    Niesen AE; Hull ML
    J Biomech; 2021 Oct; 127():110651. PubMed ID: 34371473
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Propagation of registration errors into the change in maximum total point motion for determining stability of tibial baseplates.
    Niesen AE; Hull ML
    Comput Methods Biomech Biomed Engin; 2021 Jul; 24(9):1019-1025. PubMed ID: 33400600
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Conditions for Use and Implementation of Globally-Aligned Versus Local Baseplate Coordinate Systems When Computing Migration Using Radiostereometric Analysis.
    Niesen AE; Kaptein BL; Hull ML
    J Biomech Eng; 2023 Jun; 145(6):. PubMed ID: 36719252
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reorienting the tibial baseplate improves the registration accuracy of model-based radiostereometric analysis.
    Niesen AE; Garverick AL; Howell SM; Hull ML
    J Biomech; 2020 Dec; 113():110078. PubMed ID: 33227564
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Migration of a cemented fixed-bearing, polished titanium tibial baseplate (Genesis II) at ten years : a radiostereometric analysis.
    Teeter MG; Thoren J; Yuan X; McCalden RW; MacDonald SJ; Lanting BA; Naudie DD
    Bone Joint J; 2016 May; 98-B(5):616-21. PubMed ID: 27143731
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a 3D-printed total knee arthroplasty using radiostereometric analysis: assessment of highly porous biological fixation of the tibial baseplate and metal-backed patellar component.
    Sporer S; MacLean L; Burger A; Moric M
    Bone Joint J; 2019 Jul; 101-B(7_Supple_C):40-47. PubMed ID: 31256643
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Varus tibial alignment is associated with greater tibial baseplate migration at 10 years following total knee arthroplasty.
    Teeter MG; Naudie DD; McCalden RW; Yuan X; Holdsworth DW; MacDonald SJ; Lanting BA
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1610-1617. PubMed ID: 29147742
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Are There Differences in Micromotion on Radiostereometric Analysis Between Bicruciate and Cruciate-retaining Designs in TKA? A Randomized Controlled Trial.
    Troelsen A; Ingelsrud LH; Thomsen MG; Muharemovic O; Otte KS; Husted H
    Clin Orthop Relat Res; 2020 Sep; 478(9):2045-2053. PubMed ID: 32023233
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of marker-selection method in radiostereometric analysis of total knee arthroplasty on tibial baseplate migration patterns: a secondary analysis of a randomized controlled trial with 5-year follow-up.
    Van der Lelij TJN; Koster LA; Marang-van de Mheen PJ; Toksvig-Larsen S; Nelissen RGHH; Kaptein BL
    Acta Orthop; 2024 Mar; 95():157-165. PubMed ID: 38597226
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Low tibial baseplate migration 1 year after unrestricted kinematically aligned total knee arthroplasty using a medial conforming implant design.
    Niesen AE; Garverick AL; Howell SM; Hull ML
    Knee Surg Sports Traumatol Arthrosc; 2023 Apr; 31(4):1433-1442. PubMed ID: 36201009
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The beneficial effect of hydroxyapatite lasts: a randomized radiostereometric trial comparing hydroxyapatite-coated, uncoated, and cemented tibial components for up to 16 years.
    Pijls BG; Valstar ER; Kaptein BL; Fiocco M; Nelissen RG
    Acta Orthop; 2012 Apr; 83(2):135-41. PubMed ID: 22329667
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Error in maximum total point motion of a tibial baseplate is lower with a reverse-engineered model versus a CAD model using model-based radiostereometric analysis.
    Niesen AE; Garverick AL; Howell SM; Hull ML
    J Biomech; 2022 Oct; 143():111267. PubMed ID: 36087494
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Maximum Total Point Motion of Five Points Versus All Points in Assessing Tibial Baseplate Stability.
    Niesen AE; Garverick AL; Hull ML
    J Biomech Eng; 2021 Nov; 143(11):. PubMed ID: 34076233
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparable Stability of Cemented vs Press-Fit Placed Stems in Revision Total Knee Arthroplasty With Mild to Moderate Bone Loss: 6.5-Year Results From a Randomized Controlled Trial With Radiostereometric Analysis.
    Kosse NM; van Hellemondt GG; Wymenga AB; Heesterbeek PJ
    J Arthroplasty; 2017 Jan; 32(1):197-201. PubMed ID: 27554783
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Predictive value of short-term migration in determining long-term stable fixation in cemented and cementless total knee arthroplasties.
    Laende EK; Richardson CG; Dunbar MJ
    Bone Joint J; 2019 Jul; 101-B(7_Supple_C):55-60. PubMed ID: 31256645
    [TBL] [Abstract][Full Text] [Related]  

  • 18. How Do Classic (Static) RSA and Patient Motion Artifacts Affect the Assessment of Migration of a TKA Tibial Component? An In Vitro Study.
    Cao H; Sesselmann S; Xu J; Seehaus F; Forst R
    Clin Orthop Relat Res; 2023 Feb; 481(2):400-412. PubMed ID: 36398327
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Marker-based versus model-based radiostereometric analysis of total knee arthroplasty migration: a reanalysis with comparable mean outcomes despite distinct types of measurement error.
    van Hamersveld KT; Marang-van de Mheen PJ; Koster LA; Nelissen RGHH; Toksvig-Larsen S; Kaptein BL
    Acta Orthop; 2019 Aug; 90(4):366-372. PubMed ID: 31017513
    [TBL] [Abstract][Full Text] [Related]  

  • 20. No Difference in Implant Micromotion Between Hybrid Fixation and Fully Cemented Revision Total Knee Arthroplasty: A Randomized Controlled Trial with Radiostereometric Analysis of Patients with Mild-to-Moderate Bone Loss.
    Heesterbeek PJ; Wymenga AB; van Hellemondt GG
    J Bone Joint Surg Am; 2016 Aug; 98(16):1359-69. PubMed ID: 27535438
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.