These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 37796284)

  • 21. A calcar collar is protective against early periprosthetic femoral fracture around cementless femoral components in primary total hip arthroplasty: a registry study with biomechanical validation.
    Lamb JN; Baetz J; Messer-Hannemann P; Adekanmbi I; van Duren BH; Redmond A; West RM; Morlock MM; Pandit HG
    Bone Joint J; 2019 Jul; 101-B(7):779-786. PubMed ID: 31256663
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study.
    Yan SG; Chevalier Y; Liu F; Hua X; Schreiner A; Jansson V; Schmidutz F
    J Orthop Surg Res; 2020 Oct; 15(1):498. PubMed ID: 33121506
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Uncemented extensive porous titanium-coated long femoral stem prostheses are effective in treatment of Vancouver type B2 periprosthetic femoral fractures: A retrospective mid- to long-term follow-up study.
    Wang Q; Li D; Kang P
    J Orthop Surg (Hong Kong); 2019; 27(2):2309499019857653. PubMed ID: 31232172
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Long, titanium, cemented stems decreased late periprosthetic fractures and revisions in patients with severe bone loss and previous revision.
    Hernigou P; Dupuys N; Delambre J; Guissou I; Poignard A; Allain J; Flouzat Lachaniette CH
    Int Orthop; 2015 Apr; 39(4):639-44. PubMed ID: 25231573
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Stress shielding effect after total hip arthroplasty varies between combinations of stem design and stiffness-a comparing biomechanical finite element analysis.
    Burchard R; Graw JA; Soost C; Schmitt J
    Int Orthop; 2023 Aug; 47(8):1981-1987. PubMed ID: 37269400
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Low rate of early periprosthetic fractures in cementless short-stem total hip arthroplasty using a minimally invasive anterolateral approach.
    Luger M; Hipmair G; Schopper C; Schauer B; Hochgatterer R; Allerstorfer J; Gotterbarm T; Klasan A
    J Orthop Traumatol; 2021 May; 22(1):19. PubMed ID: 34019194
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Reduced Incidence of Intraoperative Femur Fracture With a Second-Generation Tapered Wedge Stem.
    Fleischman AN; Schubert MM; Restrepo C; Chen AF; Rothman RH
    J Arthroplasty; 2017 Nov; 32(11):3457-3461. PubMed ID: 28676374
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Femoral Component Undersizing and Alignment are Risk Factors for Early Periprosthetic Femur Fracture.
    Alpaugh K; Chiu YF; Zlotnicki JP; Bendich I; Valle AGD; Bostrom MPG; Gausden EB
    J Arthroplasty; 2022 Jul; 37(7S):S604-S610. PubMed ID: 35283234
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Experimental analysis of early periprosthetic femoral fractures with uncemented straight hip stems.
    Saemann M; Darowski M; Hennicke NS; Bader R; Sander M; Kluess D
    Clin Biomech (Bristol, Avon); 2022 Jan; 91():105543. PubMed ID: 34871913
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Single Wedge Femoral Stem Designs are Associated With a Higher Risk for Revision After Cementless Primary Total Hip Arthroplasty.
    Reddy NC; Chang RN; Prentice HA; Paxton EW; Kelly MP; Khatod M
    J Arthroplasty; 2023 May; 38(5):855-861.e1. PubMed ID: 36535447
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of periprosthetic bone remodeling after implantation of anatomic and tapered cementless femoral stems in total hip arthroplasty: A prospective cohort study protocol.
    Wu XD; Chen Y; Wang ZY; Li YJ; Zhu ZL; Tao YZ; Chen H; Cheng Q; Huang W
    Medicine (Baltimore); 2018 Sep; 97(39):e12560. PubMed ID: 30278556
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Stemmed TKA in a femur with a total hip arthroplasty: is there a safe distance between the stem tips?
    Soenen M; Baracchi M; De Corte R; Labey L; Innocenti B
    J Arthroplasty; 2013 Sep; 28(8):1437-45. PubMed ID: 23489732
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Incidence and pattern of periprosthetic hip fractures around the stem in different stem geometry.
    Cottino U; Dettoni F; Caputo G; Bonasia DE; Rossi P; Rossi R
    Int Orthop; 2020 Jan; 44(1):53-59. PubMed ID: 31098685
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Perioperative Periprosthetic Femur Fractures are Strongly Correlated With Fixation Method: an Analysis From the American Joint Replacement Registry.
    Springer BD; Etkin CD; Shores PB; Gioe TJ; Lewallen DG; Bozic KJ
    J Arthroplasty; 2019 Jul; 34(7S):S352-S354. PubMed ID: 30852066
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Uncemented femoral stem design might have an impact on postoperative periprosthetic femur fracture pattern. A Comparison between flat-wedge and dual-wedge stems.
    Ma HH; Chou TA; Tsai SW; Chen CF; Wu PK; Chen WM
    Injury; 2021 Nov; 52(11):3461-3470. PubMed ID: 33648738
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Biomechanical Properties of Bionic Collum Femoris Preserving Hip Prosthesis: A Finite Element Analysis.
    Zhang X; Wang Y; Zhang L; Yu K; Ding Z; Zhang Y; Chen X; Xiong C; Ji Y; Zhang D; Ma X
    Orthop Surg; 2023 Apr; 15(4):1126-1135. PubMed ID: 36797648
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Osteoporotic Patients Undergoing Total Hip Arthroplasty Have a Similar 5-Year Cumulative Incidence Rate of Periprosthetic Fracture Regardless of Cemented Versus Cementless Femoral Stem Fixation.
    Kuyl EV; Agarwal AR; Patel PK; Harris AB; Gu A; Rao S; Thakkar SC; Golladay GJ
    J Arthroplasty; 2024 May; 39(5):1285-1290.e1. PubMed ID: 37952741
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Optimum stem length for mitigation of periprosthetic fracture risk following primary total knee arthroplasty: a finite element study.
    Conlisk N; Howie CR; Pankaj P
    Knee Surg Sports Traumatol Arthrosc; 2018 May; 26(5):1420-1428. PubMed ID: 27812774
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Undetected Intraoperative Periprosthetic Femoral Fractures in Patients Undergoing Primary Total Hip Arthroplasty: A Retrospective Case Series and Literature Review.
    Liu Y; Li C; Cao Z; Wang X; Wen J; Ping H; Kong X; Chai W
    Orthop Surg; 2023 Mar; 15(3):758-765. PubMed ID: 36647808
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effect of femoral canal shape on mechanical stress distribution and adaptive bone remodelling around a cementless tapered-wedge stem.
    Oba M; Inaba Y; Kobayashi N; Ike H; Tezuka T; Saito T
    Bone Joint Res; 2016 Sep; 5(9):362-9. PubMed ID: 27601435
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.