These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
130 related articles for article (PubMed ID: 37799029)
1. High-precision Sr and Nd isotope characterization of BHVO-2 reference material by thermal ionization mass spectrometry. Fuenlabrada JM Rapid Commun Mass Spectrom; 2023 Nov; 37(21):e9632. PubMed ID: 37799029 [TBL] [Abstract][Full Text] [Related]
2. Rapid and precise determination of Sr and Nd isotopic ratios in geological samples from the same filament loading by thermal ionization mass spectrometry employing a single-step separation scheme. Li CF; Li XH; Li QL; Guo JH; Li XH; Yang YH Anal Chim Acta; 2012 May; 727():54-60. PubMed ID: 22541823 [TBL] [Abstract][Full Text] [Related]
3. Rapid decomposition of geological samples by ammonium bifluoride (NH Újvári G; Klötzli U; Horschinegg M; Wegner W; Hippler D; Kiss GI; Palcsu L Rapid Commun Mass Spectrom; 2021 Jun; 35(11):e9081. PubMed ID: 33728686 [TBL] [Abstract][Full Text] [Related]
4. Measurement of small ion beams by thermal ionisation mass spectrometry using new 10(13) Ohm resistors. Koornneef JM; Bouman C; Schwieters JB; Davies GR Anal Chim Acta; 2014 Mar; 819():49-55. PubMed ID: 24636410 [TBL] [Abstract][Full Text] [Related]
5. A Simplified Method Using a Single N,N,N',N'-Tetraoctyl Diglycolamide Resin Column for the Purification of Sr, Nd and Hf in Geological Materials and the Determination of Their Isotopic Ratios by Multi-collector Inductively Coupled Plasma-Mass Spectrometry. Guan Q; Sun Y; Yue Y; Liu X; Zhao S Anal Sci; 2019 Mar; 35(3):323-328. PubMed ID: 30449833 [TBL] [Abstract][Full Text] [Related]
6. Isotope ratio determination in boron analysis. Sah RN; Brown PH Biol Trace Elem Res; 1998; 66(1-3):39-53. PubMed ID: 10050906 [TBL] [Abstract][Full Text] [Related]
7. Sr Isotope Analysis of Picogram-Level Samples by Thermal Ionization Mass Spectrometry Using a Highly Sensitive Silicotungstic Acid Emitter. Li CF; Chu ZY; Wang XC; Guo JH; Wilde SA Anal Chem; 2019 Jun; 91(11):7288-7294. PubMed ID: 31070889 [TBL] [Abstract][Full Text] [Related]
8. Determination of Li C; Chu Z; Wang X; Guo J; Wilde SA Talanta; 2021 Oct; 233():122537. PubMed ID: 34215040 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of neodymium isotope analysis of human dental enamel as a provenance indicator using 10 Plomp E; von Holstein ICC; Koornneef JM; Smeets RJ; Baart JA; Forouzanfar T; Davies GR Sci Justice; 2019 May; 59(3):322-331. PubMed ID: 31054821 [TBL] [Abstract][Full Text] [Related]
10. A simple two-stage column chromatographic separation scheme for strontium, lead, neodymium and hafnium isotope analyses in geological samples by thermal ionization mass spectrometry or multi-collector inductively coupled plasma mass spectrometry. Lei HL; Yang T; Jiang SY; Pu W J Sep Sci; 2019 Oct; 42(20):3261-3275. PubMed ID: 31424630 [TBL] [Abstract][Full Text] [Related]
11. Ultra-high-precision Nd-isotope measurements of geological materials by MC-ICPMS. Saji NS; Wielandt D; Paton C; Bizzarro M J Anal At Spectrom; 2016 Jul; 31(7):1490-1504. PubMed ID: 27429505 [TBL] [Abstract][Full Text] [Related]
12. High-precision 87Sr/86Sr analyses in wines and their use as a geological fingerprint for tracing geographic provenance. Marchionni S; Braschi E; Tommasini S; Bollati A; Cifelli F; Mulinacci N; Mattei M; Conticelli S J Agric Food Chem; 2013 Jul; 61(28):6822-31. PubMed ID: 23796314 [TBL] [Abstract][Full Text] [Related]
13. An evaluation of a single-step extraction chromatography separation method for Sm-Nd isotope analysis of micro-samples of silicate rocks by high-sensitivity thermal ionization mass spectrometry. Li CF; Li XH; Li QL; Guo JH; Li XH; Liu T Anal Chim Acta; 2011 Nov; 706(2):297-304. PubMed ID: 22023865 [TBL] [Abstract][Full Text] [Related]
14. Integrated Extraction Chromatographic Separation of the Lithophile Elements Involved in Long-Lived Radiogenic Isotope Systems (Rb-Sr, U-Th-Pb, Sm-Nd, La-Ce, and Lu-Hf) Useful in Geochemical and Environmental Sciences. Pin C; Gannoun A Anal Chem; 2017 Feb; 89(4):2411-2417. PubMed ID: 28192957 [TBL] [Abstract][Full Text] [Related]
15. La-Ce isotope measurements by multicollector-ICPMS. Schnabel C; Münker C; Strub E J Anal At Spectrom; 2017 Dec; 32(12):2360-2370. PubMed ID: 29456283 [TBL] [Abstract][Full Text] [Related]
16. High-precision magnesium isotope analysis of geological and environmental reference materials by multiple-collector inductively coupled plasma mass spectrometry. Gao T; Ke S; Li R; Meng X; He Y; Liu C; Wang Y; Li Z; Zhu JM Rapid Commun Mass Spectrom; 2019 Apr; 33(8):767-777. PubMed ID: 30577069 [TBL] [Abstract][Full Text] [Related]
17. A fully automated simultaneous single-stage separation of Sr, Pb, and Nd using DGA Resin for the isotopic analysis of marine sediments. Retzmann A; Zimmermann T; Pröfrock D; Prohaska T; Irrgeher J Anal Bioanal Chem; 2017 Sep; 409(23):5463-5480. PubMed ID: 28674822 [TBL] [Abstract][Full Text] [Related]
18. High-precision measurement of U-Pu-Np-Am concentrations and isotope ratios in environmental reference materials by mass spectrometry. Goldstein SJ; Price AA; Hinrichs KA; Lamont SP; Nunn AJ; Amato RS; Cardon AM; Gurganus DW J Environ Radioact; 2021 Oct; 237():106689. PubMed ID: 34298408 [TBL] [Abstract][Full Text] [Related]
19. Isotopic Analysis of Lead at Ultratrace Levels Using Thermal Ionization Mass Spectrometry (TIMS) Coupled with the Continuous Heating Method: Optimization of the Data Integration Range and Method. Park YS; Lee KS; Lim JS; Park JH J Am Soc Mass Spectrom; 2024 Jan; 35(1):158-165. PubMed ID: 38061327 [TBL] [Abstract][Full Text] [Related]
20. Sr-Nd-Hf isotopic analysis of reference materials and natural and anthropogenic particulate matter sources: Implications for accurately tracing North African dust in complex urban atmospheres. Das S; Miller BV; Prospero J; Chellam S Talanta; 2022 May; 241():123236. PubMed ID: 35074680 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]