These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

235 related articles for article (PubMed ID: 3779933)

  • 1. The influence of manual chest compression rate on hemodynamic support during cardiac arrest: high-impulse cardiopulmonary resuscitation.
    Maier GW; Newton JR; Wolfe JA; Tyson GS; Olsen CO; Glower DD; Spratt JA; Davis JW; Feneley MP; Rankin JS
    Circulation; 1986 Dec; 74(6 Pt 2):IV51-9. PubMed ID: 3779933
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improved hemodynamic performance with a novel chest compression device during treatment of in-hospital cardiac arrest.
    Timerman S; Cardoso LF; Ramires JA; Halperin H
    Resuscitation; 2004 Jun; 61(3):273-80. PubMed ID: 15172705
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A physiologic comparison of external cardiac massage techniques.
    Newton JR; Glower DD; Wolfe JA; Tyson GS; Spratt JA; Fenely MP; Rankin JS; Olsen CO
    J Thorac Cardiovasc Surg; 1988 May; 95(5):892-901. PubMed ID: 3361936
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Physiologic determinants of coronary blood flow during external cardiac massage.
    Wolfe JA; Maier GW; Newton JR; Glower DD; Tyson GS; Spratt JA; Rankin JS; Olsen CO
    J Thorac Cardiovasc Surg; 1988 Mar; 95(3):523-32. PubMed ID: 3343860
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hemodynamics of cardiac massage.
    Jackson RE; Freeman SB
    Emerg Med Clin North Am; 1983 Dec; 1(3):501-13. PubMed ID: 6396069
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improved neurological outcome with continuous chest compressions compared with 30:2 compressions-to-ventilations cardiopulmonary resuscitation in a realistic swine model of out-of-hospital cardiac arrest.
    Ewy GA; Zuercher M; Hilwig RW; Sanders AB; Berg RA; Otto CW; Hayes MM; Kern KB
    Circulation; 2007 Nov; 116(22):2525-30. PubMed ID: 17998457
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Minimal interruption of cardiopulmonary resuscitation for a single shock as mandated by automated external defibrillations does not compromise outcomes in a porcine model of cardiac arrest and resuscitation.
    Ristagno G; Tang W; Russell JK; Jorgenson D; Wang H; Sun S; Weil MH
    Crit Care Med; 2008 Nov; 36(11):3048-53. PubMed ID: 18824916
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of 15:1, 15:2, and 30:2 compression-to-ventilation ratios for cardiopulmonary resuscitation in a canine model of a simulated, witnessed cardiac arrest.
    Hwang SO; Kim SH; Kim H; Jang YS; Zhao PG; Lee KH; Choi HJ; Shin TY
    Acad Emerg Med; 2008 Feb; 15(2):183-9. PubMed ID: 18275449
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Increased cortical cerebral blood flow with LUCAS; a new device for mechanical chest compressions compared to standard external compressions during experimental cardiopulmonary resuscitation.
    Rubertsson S; Karlsten R
    Resuscitation; 2005 Jun; 65(3):357-63. PubMed ID: 15919574
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Incomplete chest wall decompression: a clinical evaluation of CPR performance by EMS personnel and assessment of alternative manual chest compression-decompression techniques.
    Aufderheide TP; Pirrallo RG; Yannopoulos D; Klein JP; von Briesen C; Sparks CW; Deja KA; Conrad CJ; Kitscha DJ; Provo TA; Lurie KG
    Resuscitation; 2005 Mar; 64(3):353-62. PubMed ID: 15733766
    [TBL] [Abstract][Full Text] [Related]  

  • 11. 2005 American Heart Association (AHA) guidelines for cardiopulmonary resuscitation (CPR) and emergency cardiovascular care (ECC) of pediatric and neonatal patients: pediatric basic life support.
    American Heart Association
    Pediatrics; 2006 May; 117(5):e989-1004. PubMed ID: 16651298
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of 2 types of chest compressions in a porcine model of cardiac arrest.
    Wu JY; Li CS; Liu ZX; Wu CJ; Zhang GC
    Am J Emerg Med; 2009 Sep; 27(7):823-9. PubMed ID: 19683111
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new device producing manual sternal compression with thoracic constraint for cardiopulmonary resuscitation.
    Niemann JT; Rosborough JP; Kassabian L; Salami B
    Resuscitation; 2006 May; 69(2):295-301. PubMed ID: 16457933
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Open-chest CPR improves survival and neurologic outcome following cardiac arrest.
    Benson DM; O'Neil B; Kakish E; Erpelding J; Alousi S; Mason R; Piper D; Rafols J
    Resuscitation; 2005 Feb; 64(2):209-17. PubMed ID: 15680532
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Incomplete chest wall decompression: a clinical evaluation of CPR performance by trained laypersons and an assessment of alternative manual chest compression-decompression techniques.
    Aufderheide TP; Pirrallo RG; Yannopoulos D; Klein JP; von Briesen C; Sparks CW; Deja KA; Kitscha DJ; Provo TA; Lurie KG
    Resuscitation; 2006 Dec; 71(3):341-51. PubMed ID: 17070644
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The biphasic mechanism of blood flow during cardiopulmonary resuscitation: a physiologic comparison of active compression-decompression and high-impulse manual external cardiac massage.
    Tucker KJ; Khan J; Idris A; Savitt MA
    Ann Emerg Med; 1994 Nov; 24(5):895-906. PubMed ID: 7978564
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Haemodynamic effects of adrenaline (epinephrine) depend on chest compression quality during cardiopulmonary resuscitation in pigs.
    Pytte M; Kramer-Johansen J; Eilevstjønn J; Eriksen M; Strømme TA; Godang K; Wik L; Steen PA; Sunde K
    Resuscitation; 2006 Dec; 71(3):369-78. PubMed ID: 17023108
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Initial defibrillation versus initial chest compression in a 4-minute ventricular fibrillation canine model of cardiac arrest.
    Wang YL; Zhong JQ; Tao W; Hou XM; Meng XL; Zhang Y
    Crit Care Med; 2009 Jul; 37(7):2250-2. PubMed ID: 19455026
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The impact of a new CPR assist device on rate of return of spontaneous circulation in out-of-hospital cardiac arrest.
    Casner M; Andersen D; Isaacs SM
    Prehosp Emerg Care; 2005; 9(1):61-7. PubMed ID: 16036830
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Could we use abdominal compressions rather than chest compression in patients who arrest after cardiac surgery?
    Adam Z; Adam S; Khan P; Dunning J
    Interact Cardiovasc Thorac Surg; 2009 Jan; 8(1):148-51. PubMed ID: 18948306
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.