BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 37804649)

  • 1. Multiphase photon counting detector CT data sets - Which combination of contrast phase and virtual non-contrast algorithm is best suited to replace true non-contrast series in the assessment of active bleeding?
    Risch F; Bette S; Sinzinger A; Rippel K; Scheurig-Muenkler C; Kroencke T; Decker JA
    Eur J Radiol; 2023 Nov; 168():111125. PubMed ID: 37804649
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of epicardial adipose tissue on virtual non-contrast images derived from photon-counting detector coronary CTA datasets.
    Risch F; Schwarz F; Braun F; Bette S; Becker J; Scheurig-Muenkler C; Kroencke TJ; Decker JA
    Eur Radiol; 2023 Apr; 33(4):2450-2460. PubMed ID: 36462042
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Virtual Non-Contrast Reconstructions of Photon-Counting Detector CT Angiography Datasets as Substitutes for True Non-Contrast Acquisitions in Patients after EVAR-Performance of a Novel Calcium-Preserving Reconstruction Algorithm.
    Decker JA; Bette S; Scheurig-Muenkler C; Jehs B; Risch F; Woźnicki P; Braun FM; Haerting M; Wollny C; Kroencke TJ; Schwarz F
    Diagnostics (Basel); 2022 Feb; 12(3):. PubMed ID: 35328111
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diagnostic performance of photon-counting detector CT for differentiation between adrenal adenomas and metastases.
    Bette S; Risch F; Canalini L; Becker J; Leithner EV; Huber A; Haerting M; Jehs B; Wollny C; Schwarz F; Tehlan K; Scheurig-Muenkler C; Wendler T; Kroencke T; Decker JA
    Eur Radiol; 2024 Mar; ():. PubMed ID: 38480567
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Virtual non-contrast series of photon-counting detector computed tomography angiography for aortic valve calcium scoring.
    Risch F; Harmel E; Rippel K; Wein B; Raake P; Girdauskas E; Elvinger S; Owais T; Scheurig-Muenkler C; Kroencke T; Schwarz F; Braun F; Decker JA
    Int J Cardiovasc Imaging; 2024 Apr; 40(4):723-732. PubMed ID: 38175389
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Heart rate sensitivity of virtual non-contrast calcium scores derived from photon counting detector CT data: a phantom study.
    Risch F; Schwarz F; Kroencke T; Decker JA
    Radiol Med; 2024 Mar; 129(3):401-410. PubMed ID: 38319495
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Image Characteristics of Virtual Non-Contrast Series Derived from Photon-Counting Detector Coronary CT Angiography-Prerequisites for and Feasibility of Calcium Quantification.
    Braun FM; Risch F; Decker JA; Woźnicki P; Bette S; Becker J; Rippel K; Scheurig-Münkler C; Kröncke TJ; Schwarz F
    Diagnostics (Basel); 2023 Nov; 13(22):. PubMed ID: 37998539
    [TBL] [Abstract][Full Text] [Related]  

  • 8. CT radiomic features reproducibility of virtual non-contrast series derived from photon-counting CCTA datasets using a novel calcium-preserving reconstruction algorithm compared with standard non-contrast series: focusing on epicardial adipose tissue.
    Cui M; Bao S; Li J; Dong H; Xu Z; Yan F; Yang W
    Int J Cardiovasc Imaging; 2024 Apr; ():. PubMed ID: 38587689
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Virtual Noncontrast Abdominal Imaging with Photon-counting Detector CT.
    Mergen V; Racine D; Jungblut L; Sartoretti T; Bickel S; Monnin P; Higashigaito K; Martini K; Alkadhi H; Euler A
    Radiology; 2022 Oct; 305(1):107-115. PubMed ID: 35670712
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparing Arterial- and Venous-Phase Acquisition for Optimization of Virtual Noncontrast Images From Dual-Energy Computed Tomography Angiography.
    Lehti L; Söderberg M; Höglund P; Wassélius J
    J Comput Assist Tomogr; 2019; 43(5):770-774. PubMed ID: 31425308
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Coronary calcium scoring on virtual non-contrast and virtual non-iodine reconstructions compared to true non-contrast images using photon-counting computed tomography.
    Sharma SP; van der Bie J; van Straten M; Hirsch A; Bos D; Dijkshoorn ML; Booij R; Budde RPJ
    Eur Radiol; 2024 Jun; 34(6):3699-3707. PubMed ID: 37940711
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Value of virtual non-contrast images to identify uncomplicated cystic renal lesions: photon-counting detector CT vs. dual-energy integrating detector CT.
    Rau S; Rau A; Stein T; Hagar MT; Faby S; Bamberg F; Weiss J
    Radiol Med; 2024 May; 129(5):669-676. PubMed ID: 38512614
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance of virtual non-contrast images generated on clinical photon-counting detector CT for emphysema quantification: proof of concept.
    Jungblut L; Sartoretti T; Kronenberg D; Mergen V; Euler A; Schmidt B; Alkadhi H; Frauenfelder T; Martini K
    Br J Radiol; 2022 Jul; 95(1135):20211367. PubMed ID: 35357902
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dual-layer spectral computed tomography: Virtual non-contrast in comparison to true non-contrast images.
    Sauter AP; Muenzel D; Dangelmaier J; Braren R; Pfeiffer F; Rummeny EJ; Noël PB; Fingerle AA
    Eur J Radiol; 2018 Jul; 104():108-114. PubMed ID: 29857855
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Photon-Counting Detector CT Angiography for Endoleak Detection After Endovascular Aortic Repair: Triphasic CT With True Noncontrast Versus Biphasic CT With Virtual Noniodine Imaging.
    Turrion Gomollon AM; Mergen V; Sartoretti T; Polacin M; Nakhostin D; Puippe G; Alkadhi H; Euler A
    Invest Radiol; 2023 Nov; 58(11):816-821. PubMed ID: 37358359
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Virtual versus true non-contrast images of the brain from spectral detector CT: comparison of attenuation values and image quality.
    Kessner R; Sommer J; Große Hokamp N; Laukamp KR; Nayate A
    Acta Radiol; 2023 Feb; 64(2):776-783. PubMed ID: 35505585
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Virtual non-contrast for evaluation of liver parenchyma and vessels: results from 25 patients using multi-phase spectral-detector CT.
    Laukamp KR; Ho V; Obmann VC; Herrmann K; Gupta A; Borggrefe J; Lennartz S; Große Hokamp N; Ramaiya N
    Acta Radiol; 2020 Aug; 61(8):1143-1152. PubMed ID: 31856581
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dedicated virtual non-contrast images adapted for liver tissue in clinical photon counting CT improve virtual non-contrast imaging in various organs beyond the liver.
    Schoenbeck D; Pauline Haag N; Elias Michael A; Michael Woeltjen M; Boriesosdick J; Saeed S; Borggrefe J; Robert Kroeger J; Henning Niehoff J
    Eur J Radiol; 2023 Oct; 167():111031. PubMed ID: 37591133
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Abdominal vessel depiction on virtual triphasic spectral detector CT: initial clinical experience.
    Lennartz S; Laukamp KR; Tandon Y; Jordan M; Große Hokamp N; Zopfs D; Pennig L; Obmann M; Gilkeson RC; Herrmann KA; Ramaiya N; Gupta A
    Abdom Radiol (NY); 2021 Jul; 46(7):3501-3511. PubMed ID: 33715050
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Virtual non-contrast images from dual-energy CT angiography of the abdominal aorta and femoral arteries: comparison with true non-contrast CT images.
    Lee MH; Park HJ; Kim JN; Kim MS; Hong SW; Park JH; Kang CH
    Br J Radiol; 2022 Sep; 95(1138):20220378. PubMed ID: 36039820
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.