BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 37806788)

  • 1. US-guided EM tracked system for HDR brachytherapy: A first in-men randomized study for whole prostate treatment.
    Lavallee MC; Cantin A; Aubin S; Lefebvre M; Marrier AS; Bouchard I; Fiset C; Villeneuve-Gauthier A; Foster W; Martin AG; Carignan D; Beaulieu L; Vigneault E
    Brachytherapy; 2024; 23(1):64-72. PubMed ID: 37806788
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Real-time electromagnetic tracking-based treatment platform for high-dose-rate prostate brachytherapy: Clinical workflows and end-to-end validation.
    Beaulieu L; Racine E; Han DY; Vigneault E; Hsu IC; Cunha JAM
    Brachytherapy; 2018; 17(1):103-110. PubMed ID: 28576644
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Commissioning of an intra-operative US guided prostate HDR system integrating an EM tracking technology.
    Lavallée MC; Cantin A; Monéger F; Lefebvre M; Foster W; Vigneault E; Beaulieu L
    Brachytherapy; 2021; 20(6):1296-1304. PubMed ID: 34272132
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of catheter displacement and anatomical variations on the dose distribution in MRI-guided focal HDR brachytherapy for prostate cancer.
    Maenhout M; van der Voort van Zyp JRN; Borot de Battisti M; Peters M; van Vulpen M; van den Bosch M; Moerland MA
    Brachytherapy; 2018; 17(1):68-77. PubMed ID: 28579419
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electromagnetic tracking for catheter reconstruction in ultrasound-guided high-dose-rate brachytherapy of the prostate.
    Bharat S; Kung C; Dehghan E; Ravi A; Venugopal N; Bonillas A; Stanton D; Kruecker J
    Brachytherapy; 2014; 13(6):640-50. PubMed ID: 24929641
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automatic multi-catheter detection using deeply supervised convolutional neural network in MRI-guided HDR prostate brachytherapy.
    Dai X; Lei Y; Zhang Y; Qiu RLJ; Wang T; Dresser SA; Curran WJ; Patel P; Liu T; Yang X
    Med Phys; 2020 Sep; 47(9):4115-4124. PubMed ID: 32484573
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: a preliminary performance study.
    Zhou J; Sebastian E; Mangona V; Yan D
    Med Phys; 2013 Feb; 40(2):021716. PubMed ID: 23387739
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An integrated system for clinical treatment verification of HDR prostate brachytherapy combining source tracking with pretreatment imaging.
    Smith RL; Hanlon M; Panettieri V; Millar JL; Matheson B; Haworth A; Franich RD
    Brachytherapy; 2018; 17(1):111-121. PubMed ID: 28958735
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Electromagnetic tracking (EMT) technology for improved treatment quality assurance in interstitial brachytherapy.
    Kellermeier M; Herbolzheimer J; Kreppner S; Lotter M; Strnad V; Bert C
    J Appl Clin Med Phys; 2017 Jan; 18(1):211-222. PubMed ID: 28291934
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy.
    Poulin E; Fekete CA; Létourneau M; Fenster A; Pouliot J; Beaulieu L
    Med Phys; 2013 Nov; 40(11):111724. PubMed ID: 24320432
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analytical HDR prostate brachytherapy planning with automatic catheter and isotope selection.
    Frank CH; Ramesh P; Lyu Q; Ruan D; Park SJ; Chang AJ; Venkat PS; Kishan AU; Sheng K
    Med Phys; 2023 Oct; 50(10):6525-6534. PubMed ID: 37650773
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance of an integrated multimodality image guidance and dose-planning system supporting tumor-targeted HDR brachytherapy for prostate cancer.
    Grajales D; Kadoury S; Shams R; Barkati M; Delouya G; Béliveau-Nadeau D; Nicolas B; Le WT; Benhacene-Boudam MK; Juneau D; DaSilva JN; Carrier JF; Hautvast G; Ménard C
    Radiother Oncol; 2022 Jan; 166():154-161. PubMed ID: 34861267
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Open MR-guided high-dose-rate (HDR) prostate brachytherapy: feasibility and initial experiences open MR-guided high-dose-rate (HDR) prostate brachytherapy.
    Lakosi F; Antal G; Vandulek C; Kovacs A; Toller GL; Rakasz I; Bajzik G; Hadjiev J; Bogner P; Repa I
    Pathol Oncol Res; 2011 Jun; 17(2):315-24. PubMed ID: 21221879
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dosimetric impact of inter-observer catheter reconstruction variability in ultrasound-based high-dose-rate prostate brachytherapy.
    Nicolae A; Murgic J; Kruljac I; Dubnitzky L; D'Alimonte L; Lu L; Cumal A; Law N; Morton G; Loblaw A; Chung HT; Ravi A
    Brachytherapy; 2018; 17(2):306-312. PubMed ID: 29239812
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dosimetric impact of contouring and needle reconstruction uncertainties in US-, CT- and MRI-based high-dose-rate prostate brachytherapy treatment planning.
    Rylander S; Buus S; Pedersen EM; Bentzen L; Tanderup K
    Radiother Oncol; 2017 Apr; 123(1):125-132. PubMed ID: 28284493
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of dwell position detection with a combined electromagnetic tracking brachytherapy system for treatment verification in pelvic brachytherapy.
    van Heerden L; Schiphof-Godart J; Christianen M; Mens JW; Franckena M; Maenhout M; Hoogeman M; Kolkman-Deurloo IK
    Radiother Oncol; 2021 Jan; 154():249-254. PubMed ID: 33038356
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A novel urethral sparing technique for high-dose-rate prostate brachytherapy after transurethral resection of the prostate.
    Kunogi H; Cunha JAM; Chang AJ; Gadzinski AJ; Shinohara K; Hsu IC
    Brachytherapy; 2017; 16(6):1113-1118. PubMed ID: 28869143
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of three-dimensional radiation therapy planning tools and intraoperative ultrasound to evaluate high dose rate prostate brachytherapy implants.
    Kini VR; Edmundson GK; Vicini FA; Jaffray DA; Gustafson G; Martinez AA
    Int J Radiat Oncol Biol Phys; 1999 Feb; 43(3):571-8. PubMed ID: 10078639
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Electromagnetic (EM) catheter path tracking in ultrasound-guided brachytherapy of the breast.
    Janssen NNY; Brastianos H; Akingbade A; Olding T; Vaughan T; Ungi T; Lasso A; Joshi C; Korzeniowski M; Falkson C; Fichtinger G
    Int J Comput Assist Radiol Surg; 2020 Oct; 15(10):1645-1652. PubMed ID: 32712885
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prostate HDR brachytherapy catheter displacement between planning and treatment delivery.
    Whitaker M; Hruby G; Lovett A; Patanjali N
    Radiother Oncol; 2011 Dec; 101(3):490-4. PubMed ID: 21889221
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.