124 related articles for article (PubMed ID: 37813110)
1. Postprandial splenic stiffness changes on magnetic resonance elastography in a young healthy population.
Obrzut M; Atamaniuk V; Ehman RL; Yin M; Cholewa M; Gutkowski K; Domka W; Obrzut B
NMR Biomed; 2024 Feb; 37(2):e5047. PubMed ID: 37813110
[TBL] [Abstract][Full Text] [Related]
2. Postprandial hepatic stiffness changes on magnetic resonance elastography in healthy volunteers.
Obrzut M; Atamaniuk V; Chen J; Obrzut B; Ehman RL; Cholewa M; Palusińska A; Gutkowski K
Sci Rep; 2021 Oct; 11(1):19786. PubMed ID: 34611231
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of Spleen Stiffness in Young Healthy Volunteers Using Magnetic Resonance Elastography.
Obrzut M; Atamaniuk V; Ehman RL; Yin M; Cholewa M; Gutkowski K; Domka W; Ozga D; Obrzut B
Diagnostics (Basel); 2023 Aug; 13(17):. PubMed ID: 37685274
[TBL] [Abstract][Full Text] [Related]
4. Predicting gastroesophageal varices through spleen magnetic resonance elastography in pediatric liver fibrosis.
Yoon H; Shin HJ; Kim MJ; Han SJ; Koh H; Kim S; Lee MJ
World J Gastroenterol; 2019 Jan; 25(3):367-377. PubMed ID: 30686904
[TBL] [Abstract][Full Text] [Related]
5. Quantitative liver MRI combining phase contrast imaging, elastography, and DWI: assessment of reproducibility and postprandial effect at 3.0 T.
Jajamovich GH; Dyvorne H; Donnerhack C; Taouli B
PLoS One; 2014; 9(5):e97355. PubMed ID: 24840288
[TBL] [Abstract][Full Text] [Related]
6. Dynamic postprandial hepatic stiffness augmentation assessed with MR elastography in patients with chronic liver disease.
Yin M; Talwalkar JA; Glaser KJ; Venkatesh SK; Chen J; Manduca A; Ehman RL
AJR Am J Roentgenol; 2011 Jul; 197(1):64-70. PubMed ID: 21701012
[TBL] [Abstract][Full Text] [Related]
7. Interplatform reproducibility of liver and spleen stiffness measured with MR elastography.
Yasar TK; Wagner M; Bane O; Besa C; Babb JS; Kannengiesser S; Fung M; Ehman RL; Taouli B
J Magn Reson Imaging; 2016 May; 43(5):1064-72. PubMed ID: 26469708
[TBL] [Abstract][Full Text] [Related]
8. Magnetic resonance elastography: feasibility of liver stiffness measurements in healthy volunteers at 3T.
Mannelli L; Godfrey E; Graves MJ; Patterson AJ; Beddy P; Bowden D; Joubert I; Priest AN; Lomas DJ
Clin Radiol; 2012 Mar; 67(3):258-62. PubMed ID: 22014555
[TBL] [Abstract][Full Text] [Related]
9. Short-Term Repeatability of Magnetic Resonance Elastography at 3.0T: Effects of Motion-Encoding Gradient Direction, Slice Position, and Meal Ingestion.
Zhang J; Arena C; Pednekar A; Lambert B; Dees D; Lee VV; Muthupillai R
J Magn Reson Imaging; 2016 Mar; 43(3):704-12. PubMed ID: 26331461
[TBL] [Abstract][Full Text] [Related]
10. MR elastography: Spleen stiffness measurements in healthy volunteers--preliminary experience.
Mannelli L; Godfrey E; Joubert I; Patterson AJ; Graves MJ; Gallagher FA; Lomas DJ
AJR Am J Roentgenol; 2010 Aug; 195(2):387-92. PubMed ID: 20651194
[TBL] [Abstract][Full Text] [Related]
11. Magnetic resonance elastography of liver and spleen: Methods and applications.
Garteiser P; Doblas S; Van Beers BE
NMR Biomed; 2018 Oct; 31(10):e3891. PubMed ID: 29369503
[TBL] [Abstract][Full Text] [Related]
12. Respiratory-triggered spin-echo echo-planar imaging-based mr elastography for evaluating liver stiffness.
Wang H; Tkach JA; Trout AT; Dumoulin CL; Dillman JR
J Magn Reson Imaging; 2019 Aug; 50(2):391-396. PubMed ID: 30584687
[TBL] [Abstract][Full Text] [Related]
13. 3D MR elastography of the pancreas in children.
Serai SD; Abu-El-Haija M; Trout AT
Abdom Radiol (NY); 2019 May; 44(5):1834-1840. PubMed ID: 30683979
[TBL] [Abstract][Full Text] [Related]
14. Robustness of MR Elastography in the Healthy Brain: Repeatability, Reliability, and Effect of Different Reconstruction Methods.
Svensson SF; De Arcos J; Darwish OI; Fraser-Green J; Storås TH; Holm S; Vik-Mo EO; Sinkus R; Emblem KE
J Magn Reson Imaging; 2021 May; 53(5):1510-1521. PubMed ID: 33403750
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of spleen stiffness in healthy volunteers using point shear wave elastography.
Giuffrè M; Macor D; Masutti F; Abazia C; Tinè F; Patti R; Buonocore MR; Colombo A; Visintin A; Campigotto M; Crocè LS
Ann Hepatol; 2019; 18(5):736-741. PubMed ID: 31054978
[TBL] [Abstract][Full Text] [Related]
16. Reliability of magnetic resonance elastography using multislice two-dimensional spin-echo echo-planar imaging (SE-EPI) and three-dimensional inversion reconstruction for assessing renal stiffness.
Low G; Owen NE; Joubert I; Patterson AJ; Graves MJ; Glaser KJ; Alexander GJ; Lomas DJ
J Magn Reson Imaging; 2015 Sep; 42(3):844-50. PubMed ID: 25537823
[TBL] [Abstract][Full Text] [Related]
17. Magnetic Resonance Elastography of the Liver: Qualitative and Quantitative Comparison of Gradient Echo and Spin Echo Echoplanar Imaging Sequences.
Wagner M; Besa C; Bou Ayache J; Yasar TK; Bane O; Fung M; Ehman RL; Taouli B
Invest Radiol; 2016 Sep; 51(9):575-81. PubMed ID: 26982699
[TBL] [Abstract][Full Text] [Related]
18. Magnetic resonance elastography SE-EPI vs GRE sequences at 3T in a pediatric population with liver disease.
Calle-Toro JS; Serai SD; Hartung EA; Goldberg DJ; Bolster BD; Darge K; Anupindi SA
Abdom Radiol (NY); 2019 Mar; 44(3):894-902. PubMed ID: 30600386
[TBL] [Abstract][Full Text] [Related]
19. Magnetic resonance elastography (MRE) for measurement of muscle stiffness of the shoulder: feasibility with a 3 T MRI system.
Hong SH; Hong SJ; Yoon JS; Oh CH; Cha JG; Kim HK; Bolster B
Acta Radiol; 2016 Sep; 57(9):1099-106. PubMed ID: 25711231
[TBL] [Abstract][Full Text] [Related]
20. Performance of C-SENSE Accelerated Rapid Liver Shear Stiffness Measurement Using Displacement Wave Polarity-Inversion Motion Encoding: An Evaluation Study.
Pednekar A; Gandhi D; Wang H; Tkach JA; Trout AT; Dillman JR
J Magn Reson Imaging; 2022 Sep; 56(3):754-765. PubMed ID: 35089614
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]