141 related articles for article (PubMed ID: 37815674)
1. The impact of actuator nozzle and surroundings condition on drug delivery using pressurized-metered dose inhalers. Jahed M; Kozinski J; Pakzad L Biomech Model Mechanobiol; 2023 Dec; 22(6):2117-2133. PubMed ID: 37815674 [TBL] [Abstract][Full Text] [Related]
2. Flow Structure and Particle Deposition Analyses for Optimization of a Pressurized Metered Dose Inhaler (pMDI) in a Model of Tracheobronchial Airway. Ahookhosh K; Saidi M; Mohammadpourfard M; Aminfar H; Hamishehkar H; Farnoud A; Schmid O Eur J Pharm Sci; 2021 Sep; 164():105911. PubMed ID: 34129919 [TBL] [Abstract][Full Text] [Related]
3. Computational analyses of a pressurized metered dose inhaler and a new drug-aerosol targeting methodology. Kleinstreuer C; Shi H; Zhang Z J Aerosol Med; 2007; 20(3):294-309. PubMed ID: 17894536 [TBL] [Abstract][Full Text] [Related]
4. Effect of Pressurized Metered Dose Inhaler Spray Characteristics and Particle Size Distribution on Drug Delivery Efficiency. Yousefi M; Inthavong K; Tu J J Aerosol Med Pulm Drug Deliv; 2017 Oct; 30(5):359-372. PubMed ID: 28463041 [TBL] [Abstract][Full Text] [Related]
5. In vitro tests for aerosol deposition. III: effect of inhaler insertion angle on aerosol deposition. Delvadia RR; Longest PW; Hindle M; Byron PR J Aerosol Med Pulm Drug Deliv; 2013 Jun; 26(3):145-56. PubMed ID: 23025452 [TBL] [Abstract][Full Text] [Related]
6. Optimizing the primary particle size distributions of pressurized metered dose inhalers by using inkjet spray drying for targeting desired regions of the lungs. Ehtezazi T; Davies MJ; Seton L; Morgan MN; Ross S; Martin GD; Hutchings IM Drug Dev Ind Pharm; 2015 Feb; 41(2):279-91. PubMed ID: 24252108 [TBL] [Abstract][Full Text] [Related]
7. Correlation Between Dynamic Spray Plume and Drug Deposition of Solution-Based Pressurized Metered-Dose Inhalers. Zhou Y; Yang B; Hong C; Shao Q; Sun N; Mao Y J Aerosol Med Pulm Drug Deliv; 2024 Oct; 37(5):232-240. PubMed ID: 39007176 [No Abstract] [Full Text] [Related]
8. Comparison of the aerosol velocity and spray duration of Respimat Soft Mist inhaler and pressurized metered dose inhalers. Hochrainer D; Hölz H; Kreher C; Scaffidi L; Spallek M; Wachtel H J Aerosol Med; 2005; 18(3):273-82. PubMed ID: 16181002 [TBL] [Abstract][Full Text] [Related]
9. The effect of actuator nozzle designs on the electrostatic charge generated in pressurised metered dose inhaler aerosols. Chen Y; Young PM; Fletcher DF; Chan HK; Long E; Lewis D; Church T; Traini D Pharm Res; 2015 Apr; 32(4):1237-48. PubMed ID: 25270573 [TBL] [Abstract][Full Text] [Related]
11. In Vitro Evaluation of Aerosol Performance and Delivery Efficiency During Mechanical Ventilation Between Soft Mist Inhaler and Pressurized Metered-Dose Inhaler. Ke WR; Wang WJ; Lin TH; Wu CL; Huang SH; Wu HD; Chen CC Respir Care; 2020 Jul; 65(7):1001-1010. PubMed ID: 32071134 [TBL] [Abstract][Full Text] [Related]
12. Design optimization of a novel pMDI actuator for systemic drug delivery. Kakade PP; Versteeg HK; Hargrave GK; Genova P; Williams Iii RC; Deaton D J Aerosol Med; 2007; 20(4):460-74. PubMed ID: 18158718 [TBL] [Abstract][Full Text] [Related]
13. Characterization of Medication Velocity and Size Distribution from Pressurized Metered-Dose Inhalers by Phase Doppler Anemometry. Alatrash A; Matida E J Aerosol Med Pulm Drug Deliv; 2016 Dec; 29(6):501-513. PubMed ID: 27504720 [TBL] [Abstract][Full Text] [Related]
14. Impact of droplet evaporation rate on resulting in vitro performance parameters of pressurized metered dose inhalers. Sheth P; Grimes MR; Stein SW; Myrdal PB Int J Pharm; 2017 Aug; 528(1-2):360-371. PubMed ID: 28599855 [TBL] [Abstract][Full Text] [Related]
15. The use of computational fluid dynamics in inhaler design. Ruzycki CA; Javaheri E; Finlay WH Expert Opin Drug Deliv; 2013 Mar; 10(3):307-23. PubMed ID: 23289401 [TBL] [Abstract][Full Text] [Related]
16. High-Speed Laser Image Analysis of Plume Angles for Pressurised Metered Dose Inhalers: The Effect of Nozzle Geometry. Chen Y; Young PM; Murphy S; Fletcher DF; Long E; Lewis D; Church T; Traini D AAPS PharmSciTech; 2017 Apr; 18(3):782-789. PubMed ID: 27317571 [TBL] [Abstract][Full Text] [Related]
17. The influence of initial atomized droplet size on residual particle size from pressurized metered dose inhalers. Sheth P; Stein SW; Myrdal PB Int J Pharm; 2013 Oct; 455(1-2):57-65. PubMed ID: 23911912 [TBL] [Abstract][Full Text] [Related]
18. The Evolution of Pressurized Metered-Dose Inhalers from Early to Modern Devices. Roche N; Dekhuijzen PN J Aerosol Med Pulm Drug Deliv; 2016 Aug; 29(4):311-27. PubMed ID: 26824873 [TBL] [Abstract][Full Text] [Related]