These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 37819349)

  • 1. Establishment of Hp(3) calibration system for eye dose monitoring in Taiwan.
    Wu CA; Chiu MC; Huang TT; Lin YC; Chu CH
    Radiat Prot Dosimetry; 2023 Oct; 199(15-16):1797-1801. PubMed ID: 37819349
    [TBL] [Abstract][Full Text] [Related]  

  • 2. AIR KERMA TO Hp(3) CONVERSION COEFFICIENTS FOR IEC 61267 RQR X-RAY RADIATION QUALITIES: APPLICATION TO DOSE MONITORING OF THE LENS OF THE EYE IN MEDICAL DIAGNOSTICS.
    Principi S; Guardiola C; Duch MA; Ginjaume M
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):45-8. PubMed ID: 26464527
    [TBL] [Abstract][Full Text] [Related]  

  • 3. ENERGY AND ANGULAR DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSEMETERS FOR EYE LENS DOSIMETRY.
    Silva EH; Knežević Ž; Struelens L; Covens P; Ueno S; Vanhavere F; Buls N
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):208-12. PubMed ID: 27143793
    [TBL] [Abstract][Full Text] [Related]  

  • 4. EURADOS 2016 INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS.
    Clairand I; Behrens R; Brodecki M; Carinou E; Domienik-Andrzejewska J; Ginjaume M; Hupe O; Roig M
    Radiat Prot Dosimetry; 2018 Dec; 182(3):317-322. PubMed ID: 30590842
    [TBL] [Abstract][Full Text] [Related]  

  • 5. DOSE MEASUREMENT PRECISION OF AN RPLD-BASED EYE LENS DOSEMETER APPLICABLE TO THE MEDICAL SECTOR.
    Kowatari M; Nagamoto K; Nakagami K; Yoshitomi H; Moritake T; Kunugita N
    Radiat Prot Dosimetry; 2022 Oct; 198(17):1303-1312. PubMed ID: 35909091
    [TBL] [Abstract][Full Text] [Related]  

  • 6. INTERCOMPARISON OF EYE LENS DOSEMETERS.
    Behrens R; Hupe O; Busch F; Denk J; Engelhardt J; Günther K; Hödlmoser H; Jordan M; Strohmaier J
    Radiat Prot Dosimetry; 2017 Apr; 174(1):6-12. PubMed ID: 27009241
    [TBL] [Abstract][Full Text] [Related]  

  • 7. FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONS.
    Clairand I; Ginjaume M; Vanhavere F; Carinou E; Daures J; Denoziere M; Silva EH; Roig M; Principi S; Van Rycheghem L
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):21-6. PubMed ID: 26163384
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monitoring the eye lens: which dose quantity is adequate?
    Behrens R; Dietze G
    Phys Med Biol; 2010 Jul; 55(14):4047-62. PubMed ID: 20601777
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of H p (3) monitoring. A 2015 review.
    Carinou E; Ferrari P; Bjelac OC; Gingaume M; Merce MS; O'Connor U
    J Radiol Prot; 2015 Sep; 35(3):R17-34. PubMed ID: 26343787
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of improved free-air ionisation chamber as absolute dosimetry standard for low-energy X rays in INER.
    Chu CH; Kuan WP; Kurosawa T; Lin UT; Chen IJ; Chen WL
    Radiat Prot Dosimetry; 2010 Feb; 138(2):99-106. PubMed ID: 19789201
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Eye lens dose in interventional cardiology.
    Principi S; Delgado Soler C; Ginjaume M; Beltran Vilagrasa M; Rovira Escutia JJ; Duch MA
    Radiat Prot Dosimetry; 2015 Jul; 165(1-4):289-93. PubMed ID: 25809107
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Air kerma to Hp(3) conversion coefficients for a new cylinder phantom for photon reference radiation qualities.
    Behrens R
    Radiat Prot Dosimetry; 2012 Sep; 151(3):450-5. PubMed ID: 22434922
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hp(0.07) photon dosemeters for eye lens dosimetry: calibration on a rod vs. a slab phantom.
    Behrens R; Engelhardt J; Figel M; Hupe O; Jordan M; Seifert R
    Radiat Prot Dosimetry; 2012 Jan; 148(2):139-42. PubMed ID: 21393309
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Establishment of ISO 4037-1 X-ray Narrow-Spectrum Series at SSDL of Algiers.
    Herrati A; Arib M; Sidahmed T; Khalal-Kouache K
    Radiat Prot Dosimetry; 2017 Apr; 174(1):35-52. PubMed ID: 27103648
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of a reliable assessment for occupational eye lens dose in nuclear medicine.
    Miyaji N; Miwa K; Iimori T; Wagatsuma K; Tsushima H; Yokotsuka N; Murata T; Kasahara T; Terauchi T
    J Appl Clin Med Phys; 2022 Aug; 23(8):e13713. PubMed ID: 35775691
    [TBL] [Abstract][Full Text] [Related]  

  • 16. ISO 4037:2019 VALIDATION OF RADIATION QUALITIES BY MEANS OF HALF-VALUE LAYER AND HP(10) DOSIMETRY.
    Bandalo V; Greiter MB; Brönner J; Hoedlmoser H
    Radiat Prot Dosimetry; 2019 Dec; 187(4):438-450. PubMed ID: 31650180
    [TBL] [Abstract][Full Text] [Related]  

  • 17. 2240 IRRADIATED PERSONAL DOSEMETERS FOR THE IC2014 EURADOS INTERCOMPARISON AT SEIBERSDORF.
    Hranitzky C
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):27-30. PubMed ID: 26311703
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Energy response of LiF:Mg, Ti dosemeters to ISO 4037 and typical diagnostic x-ray beams in Tanzania.
    Muhogora WE; Ngoye WN; Lema US; Mwalongo D
    J Radiol Prot; 2002 Jun; 22(2):175-84. PubMed ID: 12148792
    [TBL] [Abstract][Full Text] [Related]  

  • 19. COMPARISON METHODOLOGIES FOR CALIBRATION OF Hp(10) PERSONAL DOSEMETERS USING ISO 4037 AND ISO 29661 STANDARDS.
    Cardoso J; Santos L; Carvalhal G; Oliveira C
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):136-40. PubMed ID: 27179120
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Radiation eye dose to medical staff during respiratory endoscopy under X-ray fluoroscopy.
    Haga Y; Chida K; Kimura Y; Yamanda S; Sota M; Abe M; Kaga Y; Meguro T; Zuguchi M
    J Radiat Res; 2020 Sep; 61(5):691-696. PubMed ID: 32657327
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.