120 related articles for article (PubMed ID: 37819630)
1. Evaluation of calibration factors of digital survey meters in a secondary standard dosimetry laboratory.
Azah CK; Deatanyah P; Appiah PM; Osei S; Amoako JK; Sam F
Radiat Prot Dosimetry; 2024 Feb; 200(2):113-119. PubMed ID: 37819630
[TBL] [Abstract][Full Text] [Related]
2. Analysis of calibration results of radiation survey meters used for area monitoring.
Adjei D; Darko EO; Annkah JK; Amoako JK; Ofori K; Emi-Reynolds G; Obeng MK; Akomaning-Adofo E; Owusu-Manteaw P
Radiat Prot Dosimetry; 2013 Oct; 156(4):506-13. PubMed ID: 23567198
[TBL] [Abstract][Full Text] [Related]
3. A round-robin gamma stereotactic radiosurgery dosimetry interinstitution comparison of calibration protocols.
Drzymala RE; Alvarez PE; Bednarz G; Bourland JD; DeWerd LA; Ma L; Meltsner SG; Neyman G; Novotny J; Petti PL; Rivard MJ; Shiu AS; Goetsch SJ
Med Phys; 2015 Nov; 42(11):6745-56. PubMed ID: 26520764
[TBL] [Abstract][Full Text] [Related]
4. Calibration of reference KAP-meters at SSDL and cross calibration of clinical KAP-meters.
Hetland PO; Friberg EG; Ovrebø KM; Bjerke HH
Acta Oncol; 2009; 48(2):289-94. PubMed ID: 18759141
[TBL] [Abstract][Full Text] [Related]
5. Development of an Australian secondary standard for the reference air kerma rate measurement of 125I seeds.
Davies JB; Mo L; Alexiev D
Australas Phys Eng Sci Med; 2005 Sep; 28(3):196-9. PubMed ID: 16250476
[TBL] [Abstract][Full Text] [Related]
6. Traceable calibration with
Hindorf C; Jessen L; Kapidzic SC; Blakkisrud J; Dalmo J; Engelsen O; Gustafsson J; Sandström M; Sæterstøl J; Gleisner KS
Phys Med; 2023 Dec; 116():103170. PubMed ID: 37989044
[TBL] [Abstract][Full Text] [Related]
7. Calibration and validation of a quality assurance system for 90Sr/90Y radiation source trains.
Rosenthal P; Weber W; Förster A; Orth O; Köhler B; Seiler F
Phys Med Biol; 2003 Mar; 48(5):573-85. PubMed ID: 12696796
[TBL] [Abstract][Full Text] [Related]
8. Assessment of a self-inspection method and reporting measured electrometer correction factors for reference-class electrometers in radiotherapy.
Kawashima M; Varnava M; Ozawa S; Okada H; Higuchi H; Hoshino Y; Tashiro M
J Appl Clin Med Phys; 2023 Aug; 24(8):e14082. PubMed ID: 37357597
[TBL] [Abstract][Full Text] [Related]
9. Establishing IAEA TRS-457 diagnostic X-ray beam qualities at the Australian primary standard dosimetry laboratory.
Lee KL; Butler D; Bailey T
Australas Phys Eng Sci Med; 2017 Dec; 40(4):881-893. PubMed ID: 29159764
[TBL] [Abstract][Full Text] [Related]
10. [Evaluation of relative electrometer calibration factor with user beam.].
Hatanaka S; Fujisaki T; Myojoyama A; Hiraoka T; Saitoh H
Igaku Butsuri; 2008; 27(3):129-35. PubMed ID: 18367823
[TBL] [Abstract][Full Text] [Related]
11. Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry.
Candela-Juan C; Vijande J; García-Martínez T; Niatsetski Y; Nauta G; Schuurman J; Ouhib Z; Ballester F; Perez-Calatayud J
Med Phys; 2015 Aug; 42(8):4954-64. PubMed ID: 26233221
[TBL] [Abstract][Full Text] [Related]
12. Analysis of Long-Term Quality Control Data for a 137Cs Dosimetry Calibration Source.
Noey JD; Golduber RM; Kearfott KJ
Health Phys; 2021 Feb; 120(2):227-242. PubMed ID: 33315651
[TBL] [Abstract][Full Text] [Related]
13. Reference dosimetry in clinical high-energy electron beams: comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols.
Saiful Huq M; Song H; Andreo P; Houser CJ
Med Phys; 2001 Oct; 28(10):2077-87. PubMed ID: 11695769
[TBL] [Abstract][Full Text] [Related]
14. Reference dosimetry on TomoTherapy: an addendum to the 1990 UK MV dosimetry code of practice.
Thomas SJ; Aspradakis MM; Byrne JP; Chalmers G; Duane S; Rogers J; Thomas RA; Tudor GS; Twyman N;
Phys Med Biol; 2014 Mar; 59(6):1339-52. PubMed ID: 24583900
[TBL] [Abstract][Full Text] [Related]
15. Estimation of absorbed dose in clinical radiotherapy linear accelerator beams: Effect of ion chamber calibration and long-term stability.
Ravichandran R; Binukumar JP; Davis CA
J Med Phys; 2013 Oct; 38(4):205-9. PubMed ID: 24672156
[TBL] [Abstract][Full Text] [Related]
16. IAEA-AAPM TRS-483-based reference dosimetry of the new RefleXion biology-guided radiotherapy (BgRT) machine.
Mirzakhanian L; Bassalow R; Zaks D; Huntzinger C; Seuntjens J
Med Phys; 2021 Apr; 48(4):1884-1892. PubMed ID: 33296515
[TBL] [Abstract][Full Text] [Related]
17. Traceable reference dosimetry in MRI guided radiotherapy using alanine: calibration and magnetic field correction factors of ionisation chambers.
Billas I; Bouchard H; Oelfke U; Duane S
Phys Med Biol; 2021 Aug; 66(16):. PubMed ID: 34049290
[TBL] [Abstract][Full Text] [Related]
18. kQ factors for ionization chamber dosimetry in clinical proton beams.
Vatnitsky SM; Siebers JV; Miller DW
Med Phys; 1996 Jan; 23(1):25-31. PubMed ID: 8700030
[TBL] [Abstract][Full Text] [Related]
19. Absorbed dose to water based dosimetry versus air kerma based dosimetry for high-energy photon beams: an experimental study.
Palmans H; Nafaa L; De JJ; Gillis S; Hoornaert MT; Martens C; Piessens M; Thierens H; Van der Plaetsen A; Vynckier S
Phys Med Biol; 2002 Feb; 47(3):421-40. PubMed ID: 11848121
[TBL] [Abstract][Full Text] [Related]
20. Study of the influence of phantom material and size on the calibration of ionization chambers in terms of absorbed dose to water.
Arib M; Medjadj T; Boudouma Y
J Appl Clin Med Phys; 2006 Aug; 7(3):55-64. PubMed ID: 17533342
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]