128 related articles for article (PubMed ID: 37843505)
1. Measuring earplug noise attenuation: A comparison of laboratory and field methods.
Karch SJ; Federman J; Ginsberg JT; Qureshi I
J Occup Environ Hyg; 2024 Jan; 21(1):68-76. PubMed ID: 37843505
[TBL] [Abstract][Full Text] [Related]
2. Hearing protection field attenuation estimation systems and associated training for reducing workers' exposure to noise.
Morata TC; Gong W; Tikka C; Samelli AG; Verbeek JH
Cochrane Database Syst Rev; 2024 May; 5(5):CD015066. PubMed ID: 38757544
[TBL] [Abstract][Full Text] [Related]
3. Consistency of attenuation across multiple fittings of custom and non-custom earplugs.
Tufts JB; Jahn KN; Byram JP
Ann Occup Hyg; 2013 Jun; 57(5):571-80. PubMed ID: 23267007
[TBL] [Abstract][Full Text] [Related]
4. Inter-laboratory comparison of three earplug fit-test systems.
Byrne DC; Murphy WJ; Krieg EF; Ghent RM; Michael KL; Stefanson EW; Ahroon WA
J Occup Environ Hyg; 2017 Apr; 14(4):294-305. PubMed ID: 27786602
[TBL] [Abstract][Full Text] [Related]
5. Variability of real-world hearing protector attenuation measurements.
Neitzel R; Somers S; Seixas N
Ann Occup Hyg; 2006 Oct; 50(7):679-91. PubMed ID: 16782739
[TBL] [Abstract][Full Text] [Related]
6. How hearing conservation training format impacts personal attenuation ratings in U.S. Marine Corps Training Recruits.
Federman J; Karch SJ; Duhon C
Int J Audiol; 2021 Feb; 60(2):151-159. PubMed ID: 32924674
[TBL] [Abstract][Full Text] [Related]
7. Individual Fit Testing of Hearing-Protection Devices Based on Microphones in Real Ears among Workers in Industries with High-Noise-Level Manufacturing.
Chiu CC; Wan TJ
Int J Environ Res Public Health; 2020 May; 17(9):. PubMed ID: 32384734
[TBL] [Abstract][Full Text] [Related]
8. Hearing Protector Attenuation and Noise Exposure Among Metal Manufacturing Workers.
Sayler SK; Rabinowitz PM; Galusha D; Sun K; Neitzel RL
Ear Hear; 2019; 40(3):680-689. PubMed ID: 30157082
[TBL] [Abstract][Full Text] [Related]
9. Improving Hearing Protection Device Noise Attenuation Through Fit-Testing in an Occupational Health Clinic.
Hayes ME; Hammond S; Montgomery AP; Stephenson L
Workplace Health Saf; 2022 Apr; 70(4):196-204. PubMed ID: 35353017
[TBL] [Abstract][Full Text] [Related]
10. Evaluating the Effectiveness of Earplugs in Preventing Noise-Induced Hearing Loss in an Auto Parts Factory in China.
Gong W; Zhao L; Li L; Morata TC; Qiu W; Feng HA; Zhu B
Int J Environ Res Public Health; 2021 Jul; 18(13):. PubMed ID: 34281127
[TBL] [Abstract][Full Text] [Related]
11. Individual fit testing of hearing protection devices.
Voix J; Hager LD
Int J Occup Saf Ergon; 2009; 15(2):211-9. PubMed ID: 19534854
[TBL] [Abstract][Full Text] [Related]
12. Development and validation of a field microphone-in-real-ear approach for measuring hearing protector attenuation.
Berger EH; Voix J; Kieper RW; Le Cocq C
Noise Health; 2011; 13(51):163-75. PubMed ID: 21368442
[TBL] [Abstract][Full Text] [Related]
13. [Study on the fit testing for the workers wearing hearing protection device in machinery manufacturing enterprises].
Wang YN; Su SB; Liao CH; Zhong X
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2024 Jan; 42(1):16-21. PubMed ID: 38311944
[No Abstract] [Full Text] [Related]
14. Symphony orchestra musicians' use of hearing protection and attenuation of custom-made hearing protectors as measured with two different real-ear attenuation at threshold methods.
Huttunen KH; Sivonen VP; Poykko VT
Noise Health; 2011; 13(51):176-88. PubMed ID: 21368443
[TBL] [Abstract][Full Text] [Related]
15. Using a boothless audiometer to estimate personal attenuation rating in a military hearing conservation clinic.
Kulinski D; Brungart DS
JASA Express Lett; 2022 Apr; 2(4):043601. PubMed ID: 36154227
[TBL] [Abstract][Full Text] [Related]
16. The efficacy of earplugs at a major hazard facility.
Lee KH; Benke G; Mckenzie D
Phys Eng Sci Med; 2022 Mar; 45(1):107-114. PubMed ID: 35023076
[TBL] [Abstract][Full Text] [Related]
17. Hearing protector fit testing with off-shore oil-rig inspectors in Louisiana and Texas.
Murphy WJ; Themann CL; Murata TK
Int J Audiol; 2016 Nov; 55(11):688-98. PubMed ID: 27414471
[TBL] [Abstract][Full Text] [Related]
18. Improved hearing protector attenuation through the use of a lubricant.
Ryan TJ; Meier RS; Tatarka A
J Occup Environ Hyg; 2017 Nov; 14(11):931-937. PubMed ID: 28763289
[TBL] [Abstract][Full Text] [Related]
19. The viability of hearing protection device fit-testing at navy and marine corps accession points.
Federman J; Duhon C
Noise Health; 2016; 18(85):303-311. PubMed ID: 27991461
[TBL] [Abstract][Full Text] [Related]
20. A Tester to Evaluate the Correct Placement of Earplugs.
Kozlowski E; Mlynski R; Morzynski L; Swidzinski A
Int J Environ Res Public Health; 2022 Jul; 19(14):. PubMed ID: 35886333
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]