BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 37863904)

  • 21. Two plant-hosted whole-cell bacterial biosensors for detection of bioavailable Cr(VI).
    Francisco R; Branco R; Schwab S; Baldani I; Morais PV
    World J Microbiol Biotechnol; 2019 Aug; 35(8):129. PubMed ID: 31376017
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Au@gap@AuAg Nanorod Side-by-Side Assemblies for Ultrasensitive SERS Detection of Mercury and its Transformation.
    Yuan A; Wu X; Li X; Hao C; Xu C; Kuang H
    Small; 2019 Jul; 15(27):e1901958. PubMed ID: 31106526
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Construction of cadmium whole-cell biosensors and circuit amplification.
    Jia X; Liu T; Ma Y; Wu K
    Appl Microbiol Biotechnol; 2021 Jul; 105(13):5689-5699. PubMed ID: 34160647
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Development of a luminescence-based biosensor for detection of methylmercury.
    Nagata T; Muraoka T; Kiyonoa M; Pan-Hou H
    J Toxicol Sci; 2010 Apr; 35(2):231-4. PubMed ID: 20371974
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Detection of organomercurials with sensor bacteria.
    Ivask A; Hakkila K; Virta M
    Anal Chem; 2001 Nov; 73(21):5168-71. PubMed ID: 11721914
    [TBL] [Abstract][Full Text] [Related]  

  • 26. SERS and fluorescence-based ultrasensitive detection of mercury in water.
    Makam P; Shilpa R; Kandjani AE; Periasamy SR; Sabri YM; Madhu C; Bhargava SK; Govindaraju T
    Biosens Bioelectron; 2018 Feb; 100():556-564. PubMed ID: 29020666
    [TBL] [Abstract][Full Text] [Related]  

  • 27. MerR-fluorescent protein chimera biosensor for fast and sensitive detection of Hg
    Özyurt C; Üstükarcı H; Evran S; Telefoncu A
    Biotechnol Appl Biochem; 2019 Sep; 66(5):731-737. PubMed ID: 31411759
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Advances in bacterial whole-cell biosensors for the detection of bioavailable mercury: A review.
    Chen Y; Guo Y; Liu Y; Xiang Y; Liu G; Zhang Q; Yin Y; Cai Y; Jiang G
    Sci Total Environ; 2023 Apr; 868():161709. PubMed ID: 36682565
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Ultratrace Naked-Eye Colorimetric Detection of Hg
    Zhang S; Zhang D; Zhang X; Shang D; Xue Z; Shan D; Lu X
    Anal Chem; 2017 Mar; 89(6):3538-3544. PubMed ID: 28206751
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Ultrasensitive fluorescent ratio imaging probe for the detection of glutathione ultratrace change in mitochondria of cancer cells.
    Zhang H; Wang C; Wang K; Xuan X; Lv Q; Jiang K
    Biosens Bioelectron; 2016 Nov; 85():96-102. PubMed ID: 27156018
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ultrasensitive Biosensor for Detection of Mercury(II) Ions Based on DNA-Cu Nanoclusters and Exonuclease III-assisted Signal Amplification.
    Zhang H; Guan Y; Li X; Lian L; Wang X; Gao W; Zhu B; Liu X; Lou D
    Anal Sci; 2018; 34(10):1155-1161. PubMed ID: 30305592
    [TBL] [Abstract][Full Text] [Related]  

  • 32. High-throughput screening of human mercury exposure based on a low-cost naked eye-recognized biosensing platform.
    Ma BC; Guo Y; Lin YR; Zhang J; Wang XQ; Zhang WQ; Luo JG; Chen YT; Zhang NX; Lu Q; Hui CY
    Biosens Bioelectron; 2024 Mar; 248():115961. PubMed ID: 38150800
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Modulating the sensing properties of Escherichia coli-based bioreporters for cadmium and mercury.
    Kang Y; Lee W; Jang G; Kim BG; Yoon Y
    Appl Microbiol Biotechnol; 2018 Jun; 102(11):4863-4872. PubMed ID: 29627854
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A sensitive whole-cell biosensor for the simultaneous detection of a broad-spectrum of toxic heavy metal ions.
    Cerminati S; Soncini FC; Checa SK
    Chem Commun (Camb); 2015 Apr; 51(27):5917-20. PubMed ID: 25730473
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A methylene blue-mediated enzyme electrode for the determination of trace mercury(II), mercury(I), methylmercury, and mercury-glutathione complex.
    Han S; Zhu M; Yuan Z; Li X
    Biosens Bioelectron; 2001 Jan; 16(1-2):9-16. PubMed ID: 11261858
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A Recombinase-Based Genetic Circuit for Heavy Metal Monitoring.
    Akboğa D; Saltepe B; Bozkurt EU; Şeker UÖŞ
    Biosensors (Basel); 2022 Feb; 12(2):. PubMed ID: 35200383
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A GFP-based bacterial biosensor with chromosomally integrated sensing cassette for quantitative detection of Hg(II) in environment.
    Priyadarshi H; Alam A; Gireesh-Babu P; Das R; Kishore P; Kumar S; Chaudhari A
    J Environ Sci (China); 2012; 24(5):963-8. PubMed ID: 22893977
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Simultaneous determination of inorganic mercury and methylmercury compounds in natural waters.
    Logar M; Horvat M; Akagi H; Pihlar B
    Anal Bioanal Chem; 2002 Nov; 374(6):1015-21. PubMed ID: 12458412
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Fluorescent Biosensors Based on Single-Molecule Counting.
    Ma F; Li Y; Tang B; Zhang CY
    Acc Chem Res; 2016 Sep; 49(9):1722-30. PubMed ID: 27583695
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A cell-free biosensor for the detection of transcriptional inducers using firefly luciferase as a reporter.
    Pellinen T; Huovinen T; Karp M
    Anal Biochem; 2004 Jul; 330(1):52-7. PubMed ID: 15183761
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.