  • 1. Evaluation of the water-equivalent characteristics of the SP34 plastic phantom for film dosimetry in a clinical linear accelerator.
    Kim KT; Choi Y; Cho GS; Jang WI; Yang KM; Lee SS; Bahng J
    PLoS One; 2023; 18(10):e0293191. PubMed ID: 37871021
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monte Carlo study of correction factors for the use of plastic phantoms in clinical electron dosimetry.
    Araki F
    Med Phys; 2007 Nov; 34(11):4368-77. PubMed ID: 18072502
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dosimetric comparison of extended dose range film with ionization measurements in water and lung equivalent heterogeneous media exposed to megavoltage photons.
    Charland PM; Chetty IJ; Yokoyama S; Fraass BA
    J Appl Clin Med Phys; 2003; 4(1):25-39. PubMed ID: 12540816
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On the measurement of scaling factors in the RW3 plastic phantom during high energy electron beam dosimetry.
    Baghani HR; Andreoli S; Robatjazi M
    Phys Eng Sci Med; 2023 Mar; 46(1):185-195. PubMed ID: 36593380
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fluence correction factors in plastic phantoms for clinical proton beams.
    Palmans H; Symons JE; Denis JM; de Kock EA; Jones DT; Vynckier S
    Phys Med Biol; 2002 Sep; 47(17):3055-71. PubMed ID: 12361210
    [TBL] [Abstract][Full Text] [Related]  

  • 6. AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams.
    Almond PR; Biggs PJ; Coursey BM; Hanson WF; Huq MS; Nath R; Rogers DW
    Med Phys; 1999 Sep; 26(9):1847-70. PubMed ID: 10505874
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Monte Carlo calculation of monitor unit for electron arc therapy.
    Chow JC; Jiang R
    Med Phys; 2010 Apr; 37(4):1571-8. PubMed ID: 20443478
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electron fluence correction factors for conversion of dose in plastic to dose in water.
    Ding GX; Rogers DW; Cygler JE; Mackie TR
    Med Phys; 1997 Feb; 24(2):161-76. PubMed ID: 9048356
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pencil beam approach for correcting the energy dependence artifact in film dosimetry for IMRT verification.
    Kirov AS; Caravelli G; Palm A; Chui C; LoSasso T
    Med Phys; 2006 Oct; 33(10):3690-9. PubMed ID: 17089835
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mean energy, energy-range relationships and depth-scaling factors for clinical electron beams.
    Ding GX; Rogers DW
    Med Phys; 1996 Mar; 23(3):361-76. PubMed ID: 8815379
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small-field animal irradiation studies.
    Ba Sunbul N; Oraiqat I; Rosen B; Miller C; Meert C; Matuszak MM; Clarke S; Pozzi S; Moran JM; El Naqa I
    Med Phys; 2021 Mar; 48(3):1404-1416. PubMed ID: 33378092
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Radiographic film dosimetry of proton beams for depth-dose constancy check and beam profile measurement.
    Yeo IJ; Teran A; Ghebremedhin A; Johnson M; Patyal B
    J Appl Clin Med Phys; 2015 May; 16(3):5402. PubMed ID: 26103499
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of ionisation measurements in water and polystyrene for electron beam dosimetry.
    Bruinvis IA; Heukelom S; Mijnheer BJ
    Phys Med Biol; 1985 Oct; 30(10):1043-53. PubMed ID: 4070361
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparing the dosimeter-specific corrections for influence quantities of some parallel-plate ionization chambers in conventional electron beam dosimetry.
    Baghani HR; Robatjazi M; Andreoli S
    Appl Radiat Isot; 2022 Jan; 179():110031. PubMed ID: 34801928
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry.
    Araki F; Hanyu Y; Fukuoka M; Matsumoto K; Okumura M; Oguchi H
    Med Phys; 2009 Jul; 36(7):2992-3001. PubMed ID: 19673198
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dosimetry of very high energy electrons (VHEE) for radiotherapy applications: using radiochromic film measurements and Monte Carlo simulations.
    Subiel A; Moskvin V; Welsh GH; Cipiccia S; Reboredo D; Evans P; Partridge M; DesRosiers C; Anania MP; Cianchi A; Mostacci A; Chiadroni E; Di Giovenale D; Villa F; Pompili R; Ferrario M; Belleveglia M; Di Pirro G; Gatti G; Vaccarezza C; Seitz B; Isaac RC; Brunetti E; Wiggins SM; Ersfeld B; Islam MR; Mendonca MS; Sorensen A; Boyd M; Jaroszynski DA
    Phys Med Biol; 2014 Oct; 59(19):5811-29. PubMed ID: 25207591
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams.
    Hill R; Holloway L; Baldock C
    Phys Med Biol; 2005 Nov; 50(21):N331-44. PubMed ID: 16237233
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Experimental assessment of out-of-field dose components in high energy electron beams used in external beam radiotherapy.
    Alabdoaburas MM; Mege JP; Chavaudra J; Bezin JV; Veres A; de Vathaire F; Lefkopoulos D; Diallo I
    J Appl Clin Med Phys; 2015 Nov; 16(6):435–448. PubMed ID: 26699572
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Consequences of air around an ionization chamber: Are existing solid phantoms suitable for reference dosimetry on an MR-linac?
    Hackett SL; van Asselen B; Wolthaus JW; Kok JG; Woodings SJ; Lagendijk JJ; Raaymakers BW
    Med Phys; 2016 Jul; 43(7):3961. PubMed ID: 27370114
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Experimental determination of depth-scaling factors and central axis depth dose for clinical electron beams.
    Huq MS; Yue N; Suntharalingam N
    Int J Cancer; 2001 Aug; 96(4):232-7. PubMed ID: 11474497
    [TBL] [Abstract][Full Text] [Related]  