  • 1. [Study on the difference of high frequency dielectric properties of biological tissues measured by air and packed coaxial probe].
    Qin Y; Yang L; Fu F; Dai M; Zhang L
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2023 Oct; 40(5):886-893. PubMed ID: 37879917
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improved circuit model of open-ended coaxial probe for measurement of the biological tissue dielectric properties between megahertz and gigahertz.
    Zhang L; Shi X; You F; Liu P; Dong X
    Physiol Meas; 2013 Oct; 34(10):N83-96. PubMed ID: 24021242
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Sensing volume of tissue dielectric property measurement with open-ended coaxial probe].
    Liu Y; Huang Y; Xin X; Yu X
    Nan Fang Yi Ke Da Xue Xue Bao; 2020 Jul; 40(7):1036-1043. PubMed ID: 32895168
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Study on the effective measurement area of an open-ended coaxial probe for the dielectric measurement of biological tissues.
    Zhang L; Liu B; Ji Z
    Technol Health Care; 2023; 31(2):621-633. PubMed ID: 36314231
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Penetration of electromagnetic fields of an open-ended coaxial probe between 1 MHz and 1 GHz in dielectric skin measurements.
    Alanen E; Lahtinen T; Nuutinen J
    Phys Med Biol; 1999 Jul; 44(7):N169-76. PubMed ID: 10442720
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validation of a Broadband Tissue-Equivalent Liquid for SAR Measurement and Monitoring of Its Dielectric Properties for Use in a Sealed Phantom.
    Gregory AP; Quéléver K; Allal D; Jawad O
    Sensors (Basel); 2020 May; 20(10):. PubMed ID: 32456139
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Machine learning aided diagnosis of hepatic malignancies through in vivo dielectric measurements with microwaves.
    Yilmaz T; Kılıç MA; Erdoğan M; Çayören M; Tunaoğlu D; Kurtoğlu İ; Yaslan Y; Çayören H; Arkan AE; Teksöz S; Cancan G; Kepil N; Erdamar S; Özcan M; Akduman İ; Kalkan T
    Phys Med Biol; 2016 Jul; 61(13):5089-5102. PubMed ID: 27321132
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dielectric Permittivity Measurement Using Open-Ended Coaxial Probe-Modeling and Simulation Based on the Simple Capacitive-Load Model.
    Šarolić A; Matković A
    Sensors (Basel); 2022 Aug; 22(16):. PubMed ID: 36015790
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design analysis and validation of coaxial probe for tissue dielectric properties evaluation used in specific absorption rate measurement.
    Naik BV
    Electromagn Biol Med; 2022 Jan; 41(1):60-70. PubMed ID: 34856852
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Comparison of dielectric properties of normal human esophagus and esophageal cancer using an open-ended coaxial probe].
    Huang Q; Lu D; Han J; Yu H; Dong W; Cai K; Yu X
    Nan Fang Yi Ke Da Xue Xue Bao; 2021 Nov; 41(11):1741-1746. PubMed ID: 34916203
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design of a simple radio frequency circuit for implementing the open-ended coaxial probe method for permittivity measurement.
    Aboyewa OB; Akinleye HB; Wrubel JP; Nichols MG
    Rev Sci Instrum; 2022 Nov; 93(11):114705. PubMed ID: 36461424
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Towards Non-Invasive Diagnosis of Skin Cancer: Sensing Depth Investigation of Open-Ended Coaxial Probes.
    Aydinalp C; Joof S; Yilmaz T
    Sensors (Basel); 2021 Feb; 21(4):. PubMed ID: 33673259
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Open-Ended Coaxial Probe Technique for Dielectric Measurement of Biological Tissues: Challenges and Common Practices.
    La Gioia A; Porter E; Merunka I; Shahzad A; Salahuddin S; Jones M; O'Halloran M
    Diagnostics (Basel); 2018 Jun; 8(2):. PubMed ID: 29874833
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Dielectric properties of tidal volume changes in rabbit lung tissue in the 100 MHz~1 GHz band].
    Qin Y; Zhang L; Liu Y; Fu F; Yang B; Yang L; Liu X; Dai M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2024 Jun; 41(3):447-454. PubMed ID: 38932529
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [The simulative study of a new probe for the
    Zhang L; Zhang X; Zhou D; Li G; Liu P
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2018 Feb; 35(1):106-114. PubMed ID: 29745609
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Precise dielectric property measurements and E-field probe calibration for specific absorption rate measurements using a rectangular waveguide.
    Hakim BM; Beard BB; Davis CC
    Meas Sci Technol; 2009 Feb; 20(4):. PubMed ID: 29520129
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An Analysis of Open-Ended Coaxial Probe Sensitivity to Heterogeneous Media.
    Brace CL; Etoz S
    Sensors (Basel); 2020 Sep; 20(18):. PubMed ID: 32961742
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of Open-Ended Coaxial Probe-to-Tissue Contact Pressure on Dielectric Measurements.
    Maenhout G; Markovic T; Ocket I; Nauwelaers B
    Sensors (Basel); 2020 Apr; 20(7):. PubMed ID: 32268598
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Analysis of dielectric properties of metastatic and non-metastatic lymph nodes from lung cancer surgeries using an open-ended coaxial probe].
    Sun Y; Yu H; Zhou D; Xin X; Lu D; Cai K; Yu X
    Nan Fang Yi Ke Da Xue Xue Bao; 2019 Nov; 39(11):1364-1369. PubMed ID: 31852649
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dielectric characterization of healthy and malignant colon tissues in the 0.5-18 GHz frequency band.
    Fornes-Leal A; Garcia-Pardo C; Frasson M; Pons Beltrán V; Cardona N
    Phys Med Biol; 2016 Oct; 61(20):7334-7346. PubMed ID: 27694718
    [TBL] [Abstract][Full Text] [Related]  