These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 3789438)

  • 21. Breathing system malfunction and the 'extra circuit'.
    Sanehi O
    Anaesthesia; 2003 Nov; 58(11):1131-2; discussion 1132. PubMed ID: 14616614
    [No Abstract]   [Full Text] [Related]  

  • 22. An unusual cause of carbon dioxide rebreathing: the puzzling device.
    Possamai C; Corbanese U
    Anesth Analg; 1995 Aug; 81(2):434-5. PubMed ID: 7618755
    [No Abstract]   [Full Text] [Related]  

  • 23. Inspiratory valve malfunction in a circle system: pitfalls in capnography.
    Kumar AY; Bhavani-Shankar K; Moseley HS; Delph Y
    Can J Anaesth; 1992 Nov; 39(9):997-9. PubMed ID: 1451230
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Hypercarbia and arrhythmias resulting from faulty Bain circuit: a report of two cases.
    Ghai B; Makkar JK; Bhatia A
    Anesth Analg; 2006 Jun; 102(6):1903-4. PubMed ID: 16717351
    [No Abstract]   [Full Text] [Related]  

  • 25. Pre-use testing of coaxial circuits: the perils of Pethick.
    Beauprie IG; Clark AG; Keith IC; Spence D
    Can J Anaesth; 1990 May; 37(4 Pt 2):S103. PubMed ID: 2113836
    [No Abstract]   [Full Text] [Related]  

  • 26. Paediatric anaesthetic breathing systems.
    Lin YC; Brock-Utne JG
    Paediatr Anaesth; 1996; 6(1):1-5. PubMed ID: 8839081
    [No Abstract]   [Full Text] [Related]  

  • 27. A design fault of the Dräger Cato anaesthesia workstation.
    Beh T
    Anaesth Intensive Care; 2006 Feb; 34(1):125; discussion 125-6. PubMed ID: 16494169
    [No Abstract]   [Full Text] [Related]  

  • 28. Preliminary evaluation of the Enclosed Magill Breathing System.
    Bruce WE; Soni NC
    Br J Anaesth; 1989 Feb; 62(2):144-9. PubMed ID: 2493797
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Non-zero basal oxygen flow a hazard to anesthesia breathing circuit leak test.
    Tokumine J; Sugahara K; Gushiken K; Ohta M; Matsuyama T; Saikawa S
    Anesth Analg; 2005 Apr; 100(4):1056-1058. PubMed ID: 15781521
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Bain system for use with the circle absorption system.
    Hale GJ
    Anaesthesia; 1990 Jan; 45(1):73-4. PubMed ID: 2316863
    [No Abstract]   [Full Text] [Related]  

  • 31. Malfunction of Hudson electrochemical oxygen sensor.
    Baker AJ; Hall R
    Anaesth Intensive Care; 1989 Nov; 17(4):516-8. PubMed ID: 2688479
    [No Abstract]   [Full Text] [Related]  

  • 32. Low-flow anaesthesia in infants and children.
    Meakin GH
    Br J Anaesth; 1999 Jul; 83(1):50-7. PubMed ID: 10616333
    [No Abstract]   [Full Text] [Related]  

  • 33. Don't let the Bain take the blame.
    Uncles DR; Parke TJ
    Can J Anaesth; 1994 Oct; 41(10):1015. PubMed ID: 8001199
    [No Abstract]   [Full Text] [Related]  

  • 34. A new closed-loop control system for isoflurane using bispectral index outperforms manual control.
    Locher S; Stadler KS; Boehlen T; Bouillon T; Leibundgut D; Schumacher PM; Wymann R; Zbinden AM
    Anesthesiology; 2004 Sep; 101(3):591-602. PubMed ID: 15329583
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Incompatibility of Nellcor ADAP-PS gas sampling tee and Dryden CPRAM breathing circuit.
    Health Devices; 1989 Oct; 18(10):364-5. PubMed ID: 2628398
    [No Abstract]   [Full Text] [Related]  

  • 36. Anesthesia case of the month. Severe twist in the inner tube of the coaxial breathing circuit, resulting in obstruction of the inspiratory limb of the circuit.
    Quandt JE
    J Am Vet Med Assoc; 2005 Dec; 227(12):1902-4. PubMed ID: 16379624
    [No Abstract]   [Full Text] [Related]  

  • 37. Unusual cause of leak in Datex Aisys.
    Kummar P; Korula G; Kumar S; Saravanan PA
    Anesth Analg; 2009 Oct; 109(4):1350-1; discussion 1351-2. PubMed ID: 19762773
    [No Abstract]   [Full Text] [Related]  

  • 38. Novel breathing circuit architecture: new consequences of old problems.
    Sandberg WS; Kaiser S
    Anesthesiology; 2004 Mar; 100(3):755-6; discussion 756. PubMed ID: 15109007
    [No Abstract]   [Full Text] [Related]  

  • 39. Undetected leak in corrugated circuit tubing in compressed configuration.
    Reinhart DJ; Friz R
    Anesthesiology; 1993 Jan; 78(1):218. PubMed ID: 8424566
    [No Abstract]   [Full Text] [Related]  

  • 40. Automated checkout routines in anesthesia workstations vary in detection and management of breathing circuit obstruction.
    Dosch MP
    Anesth Analg; 2014 Jun; 118(6):1254-7. PubMed ID: 24846195
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.