150 related articles for article (PubMed ID: 37896737)
21. Assessment of Ventilation Distribution during Laparoscopic Bariatric Surgery: An Electrical Impedance Tomography Study.
Stankiewicz-Rudnicki M; Gaszynski W; Gaszynski T
Biomed Res Int; 2016; 2016():7423162. PubMed ID: 28058262
[No Abstract] [Full Text] [Related]
22. Effect of Electrode Belt and Body Positions on Regional Pulmonary Ventilation- and Perfusion-Related Impedance Changes Measured by Electric Impedance Tomography.
Ericsson E; Tesselaar E; Sjöberg F
PLoS One; 2016; 11(6):e0155913. PubMed ID: 27253433
[TBL] [Abstract][Full Text] [Related]
23. Is there a need for individualized adjustment of electrode belt position during EIT-guided titration of positive end-expiratory pressure?
Zhao Z; Chen TF; Teng HC; Wang YC; Chang MY; Chang HT; Frerichs I; Fu F; Möller K
Physiol Meas; 2022 Jun; 43(6):. PubMed ID: 35617942
[No Abstract] [Full Text] [Related]
24. Electrical impedance tomography: changes in distribution of pulmonary ventilation during laparoscopic surgery in a porcine model.
Meier T; Leibecke T; Eckmann C; Gosch UW; Grossherr M; Bruch HP; Gehring H; Leonhardt S
Langenbecks Arch Surg; 2006 Aug; 391(4):383-9. PubMed ID: 16555085
[TBL] [Abstract][Full Text] [Related]
25. Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial.
Bikker IG; Preis C; Egal M; Bakker J; Gommers D
Crit Care; 2011 Aug; 15(4):R193. PubMed ID: 21834953
[TBL] [Abstract][Full Text] [Related]
26. Positive end-expiratory pressure individualization guided by continuous end-expiratory lung volume monitoring during laparoscopic surgery.
Tusman G; Wallin M; Acosta C; Santanera B; Portela F; Viotti F; Fuentes N; Hallbäck M; Suarez-Sipmann F
J Clin Monit Comput; 2022 Oct; 36(5):1557-1567. PubMed ID: 34966951
[TBL] [Abstract][Full Text] [Related]
27. Impact of PEEP during laparoscopic surgery on early postoperative ventilation distribution visualized by electrical impedance tomography.
Karsten J; Heinze H; Meier T
Minerva Anestesiol; 2014 Feb; 80(2):158-66. PubMed ID: 23877309
[TBL] [Abstract][Full Text] [Related]
28. The influence of an electrical impedance tomography belt on lung function determined by spirometry in sitting position.
Zhang N; Jiang H; Zhang C; Li Q; Li Y; Zhang B; Deng J; Niu G; Yang B; Frerichs I; Moeller K; Fu F; Zhao Z
Physiol Meas; 2020 May; 41(4):044002. PubMed ID: 32160596
[TBL] [Abstract][Full Text] [Related]
29. Influence of different PEEP levels on electrical impedance tomography findings in patients under general anesthesia ventilated in the lateral decubitus position.
Šribar A; Merc V; Peršec Z; Peršec J; Milas I; Husedžinović S
J Clin Monit Comput; 2020 Apr; 34(2):311-318. PubMed ID: 31062131
[TBL] [Abstract][Full Text] [Related]
30. Individualised positive end-expiratory pressure titrated intra-operatively by electrical impedance tomography optimises pulmonary mechanics and reduces postoperative atelectasis: A randomised controlled trial.
Ma X; Fu Y; Piao X; De Santis Santiago RR; Ma L; Guo Y; Fu Q; Mi W; Berra L; Zhang C
Eur J Anaesthesiol; 2023 Nov; 40(11):805-816. PubMed ID: 37789753
[TBL] [Abstract][Full Text] [Related]
31. Bedside Contribution of Electrical Impedance Tomography to Setting Positive End-Expiratory Pressure for Extracorporeal Membrane Oxygenation-treated Patients with Severe Acute Respiratory Distress Syndrome.
Franchineau G; Bréchot N; Lebreton G; Hekimian G; Nieszkowska A; Trouillet JL; Leprince P; Chastre J; Luyt CE; Combes A; Schmidt M
Am J Respir Crit Care Med; 2017 Aug; 196(4):447-457. PubMed ID: 28103448
[TBL] [Abstract][Full Text] [Related]
32. Positioning of electrode plane systematically influences EIT imaging.
Krueger-Ziolek S; Schullcke B; Kretschmer J; Müller-Lisse U; Möller K; Zhao Z
Physiol Meas; 2015 Jun; 36(6):1109-18. PubMed ID: 26006327
[TBL] [Abstract][Full Text] [Related]
33. Electrical Impedance Tomography-guided PEEP Titration in Patients Undergoing Laparoscopic Abdominal Surgery.
He X; Jiang J; Liu Y; Xu H; Zhou S; Yang S; Shi X; Yuan H
Medicine (Baltimore); 2016 Apr; 95(14):e3306. PubMed ID: 27057904
[TBL] [Abstract][Full Text] [Related]
34. Titration of extra-PEEP against intrinsic-PEEP in severe asthma by electrical impedance tomography: A case report and literature review.
He H; Yuan S; Yi C; Long Y; Zhang R; Zhao Z
Medicine (Baltimore); 2020 Jun; 99(26):e20891. PubMed ID: 32590795
[TBL] [Abstract][Full Text] [Related]
35. Regional expiratory time constants in severe respiratory failure estimated by electrical impedance tomography: a feasibility study.
Karagiannidis C; Waldmann AD; Róka PL; Schreiber T; Strassmann S; Windisch W; Böhm SH
Crit Care; 2018 Sep; 22(1):221. PubMed ID: 30236123
[TBL] [Abstract][Full Text] [Related]
36. Estimation of changes in cyclic lung strain by electrical impedance tomography: Proof-of-concept study.
Cornejo R; Iturrieta P; Olegário TMM; Kajiyama C; Arellano D; Guiñez D; Cerda MA; Brito R; Gajardo AIJ; Lazo M; López L; Morais CCA; González S; Zavala M; Rojas V; Medel JN; Hurtado DE; Bruhn A; Ramos C; Estuardo N
Acta Anaesthesiol Scand; 2021 Feb; 65(2):228-235. PubMed ID: 33037607
[TBL] [Abstract][Full Text] [Related]
37. Positive End-expiratory Pressure and Distribution of Ventilation in Pneumoperitoneum Combined with Steep Trendelenburg Position.
Shono A; Katayama N; Fujihara T; Böhm SH; Waldmann AD; Ugata K; Nikai T; Saito Y
Anesthesiology; 2020 Mar; 132(3):476-490. PubMed ID: 31770148
[TBL] [Abstract][Full Text] [Related]
38. Optimal positive end-expiratory pressure titration of intraoperative mechanical ventilation in different operative positions of female patients under general anesthesia.
Shu B; Zhang Y; Ren Q; Zheng X; Zhang Y; Liu Q; Li S; Chen J; Chen Y; Duan G; Huang H
Heliyon; 2023 Oct; 9(10):e20552. PubMed ID: 37822628
[TBL] [Abstract][Full Text] [Related]
39. Electric impedance tomography-guided PEEP titration reduces mechanical power in ARDS: a randomized crossover pilot trial.
Jimenez JV; Munroe E; Weirauch AJ; Fiorino K; Culter CA; Nelson K; Labaki WW; Choi PJ; Co I; Standiford TJ; Prescott HC; Hyzy RC
Crit Care; 2023 Jan; 27(1):21. PubMed ID: 36650593
[TBL] [Abstract][Full Text] [Related]
40. Use of Electrical Impedance Tomography (EIT) to Estimate Global and Regional Lung Recruitment Volume (VREC) Induced by Positive End-Expiratory Pressure (PEEP): An Experiment in Pigs with Lung Injury.
Wang YM; Sun XM; Zhou YM; Chen JR; Cheng KM; Li HL; Yang YL; Zhang L; Zhou JX
Med Sci Monit; 2020 Mar; 26():e922609. PubMed ID: 32172276
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]